This study aims to investigate acceptance and performance of the Bluetooth Low Energy Audio-enabled (LE Audio) firmware in the Nucleus 8 Processing Unit, Kanso 3 Nexa Sound Processor, and the Kanso 3 Sound Processor. The investigation includes actual use (take home) of LE Audio firmware releases and the new GN ReSound LE Audio wireless accessories, including the Multi-Mic+, for use in the real-world. Using the final versions of firmware, speech perception performance in noise will be investigated using the Nucleus 8 and Kanso 3 Sound Processors streaming via a Multi-Mic+.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| All Participants | Experimental | Participants will be fit with either Nucleus 8 or Kanso 3 Sound Processors with LE Audio investigational firmware. Comparisons will be made within-participant with repeated measures for each of the speech perception scores in noise conditions. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Nucleus 8 Sound Processor streaming via MultiMic+ | Device | The Nucleus 8 Sound Processor streaming audio via the Multi-Mic+ wireless microphone accessory. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Paired difference in City University of New York (CUNY) Sentences scores (% words correct) in classroom-like noise between the Nucleus 8 streaming via Multi-Mic+ and Nucleus 8 processor microphones (SCAN 2) at 0 dB SNR in 65 dB SPL | At ad-hoc visits between enrolment and 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Paired difference in CUNY Sentences scores (% words correct) in classroom-like noise between Nucleus 8 streaming via the Multi-Mic+ and Nucleus 8 streaming via the Roger 20 system at -15 dB SNR in 65 dB SPL | At ad-hoc visits between enrolment and 12 months | |
| Paired difference in CUNY Sentences scores (% words correct) in classroom-like noise between Kanso 3 streaming via Multi-Mic+ and Kanso 3 processor microphones (SCAN 2) at 0 dB SNR in 65 dB SPL |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| PRS Specialist | Contact | +61294286555 | cltd-prs-admin@cochlear.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cochlear Limited | Recruiting | Sydney | New South Wales | 2109 | Australia |
Cochlear do not have an approved platform for public sharing of IPD collected in this study. Data may be provided to individual researchers on request.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Nucleus 8 Sound Processor microphones | Device | Nucleus 8 Sound Processor streaming via the Nucleus 8 Sound Processor microphones (SCAN 2). |
|
| Nucleus 8 Sound Processor streaming via Roger 20 | Device | Nucleus 8 Sound Processor streaming audio via the Roger 20 wireless microphone accessory. |
|
| Kanso 3 Sound Processor streaming via Multi-Mic+ | Device | Kanso 3 Sound Processor streaming audio via the Multi-Mic+ wireless microphone accessory. This includes the Kanso 3 Nexa Sound Processor. |
|
| Kanso 3 Sound Processor microphone | Device | Kanso 3 Sound Processor streaming audio via the Kanso 3 Sound Processor microphones (SCAN 2). This includes the Kanso 3 Nexa Sound Processor. |
|
| At ad-hoc visits between enrolment and 12 months |
| Ratings based on the Device Use Questionnaire after a minimum of two weeks actual-use of the new GN ReSound accessories in the real-world environment | The custom device use questionnaire is designed to collect information regarding the participants' experience using the research sound processors with the interventional accessories using a 5-point Likert scale (very satisfied, satisfied, neither dissatisfied nor satisfied, dissatisfied, very dissatisfied) | At ad-hoc visits between enrolment and 12 months |