To assess and compare the accuracy of digital scans obtained using three different scanning protocols -conventional scan bodies, Intra-oral photogrammetry, and calibrated scan flags- on completely edentulous dental model with full-arch implants.
Digital scans have revolutionized prosthetic workflows by offering increased efficiency and accuracy compared to conventional techniques . Studies highlight that their accuracy depends on the scanning protocol and equipment used. Conventional scan bodies, which are well-established and commonly used for digital scans, are generally reliable; however, their accuracy can be influenced by factors such as angulation, the number of implants, and the scanning technique. Intra-oral photogrammetry has gained attention for its ability to accurately record implant positions without relying on physical scan bodies . Many systems utilize this technology to improve accuracy, particularly in complex full-arch cases, though direct comparisons with other methods remain limited. Calibrated Scan Flags represent a novel approach, incorporating enhanced features to reduce errors associated with angulation and improve the capture of implant positions. While initial studies suggest improved precision, further comparative data are required . Previous research comparing these methods often focuses on isolated factors, such as time efficiency or user preferences, with limited emphasis on accuracy. Therefore, a direct comparative analysis of these three scanning protocols is needed to address this gap.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| conventional scan bodies | Active Comparator | Digital scans using conventional scan bodies scanned with a desktop scanner. |
|
| scan bodies scanned with an intra-oral scanner | Experimental | Digital scans using conventional scan bodies scanned with an intra-oral scanner. |
|
| intra-oral photogrammetry | Experimental | Digital scans using intra-oral photogrammetry scanned with an intra-oral scanner. |
|
| calibrated scan flags | Experimental | Digital scans using calibrated scan flags scanned with an intra-oral scanner. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Intervention 1 | Procedure | Digital scans using conventional scan bodies scanned with an intra-oral scanner. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy of multiunit abutment positions | positions and angles of the multiunit abutments | 7 days |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Mohamed Sherif El Saharty | Contact | 01001646146 | 002 | saharty@hotmail.com |
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 34893053 | Result | Ma B, Yue X, Sun Y, Peng L, Geng W. Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study. BMC Oral Health. 2021 Dec 10;21(1):636. doi: 10.1186/s12903-021-02005-0. | |
| 24278919 | Result | Buzayan M, Baig MR, Yunus N. Evaluation of accuracy of complete-arch multiple-unit abutment-level dental implant impressions using different impression and splinting materials. Int J Oral Maxillofac Implants. 2013 Nov-Dec;28(6):1512-20. doi: 10.11607/jomi.2958. |
Not provided
Not provided
Will be decided after getting the results
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Intervention 2 | Procedure | Digital scans using intra-oral photogrammetry scanned with an intra-oral scanner. |
|
| Intervention 3 | Procedure | Digital scans using calibrated scan flags scanned with an intra-oral scanner. |
|
| Control | Procedure | Digital scans using conventional scan bodies scanned with a desktop scanner. |
|