This study will compare the performance of a novel data-driven model-predictive controller (MPC) based functional electrical stimulation (FES) system versus a conventional FES system for footdrop correction during treadmill and overground walking tasks in people post-stroke.
Functional electrical stimulation (FES) is a common rehabilitation tool that incorporates electrical stimulation timed with a functional task to augment paretic muscle function in people with neuro-pathologies such as stroke and spinal cord injury. The rigor of previous research has established the safety, as well as both neuro-prosthetic and therapeutic effects of FES systems for standing, walking, and grasping. Stroke is the leading cause of disability, and footdrop is a highly prevalent post-stroke gait deficit, leading to insufficient ankle dorsiflexion during the swing phase of gait, and contributing to reduced mobility. FES systems that correct footdrop to improve gait function and reduce fall risk are gaining popularity, with commercial systems such as enhancing translation potential. Despite their promising functional value, accessibility, and positive neuroplasticity effects, current FES systems have some fundamental limitations, which limit their clinical prescription.
The goal of this project is to overcome two major limitations and technical gaps in FES: rapid onset of muscle fatigue during FES and lack of sophisticated closed-loop control of FES intensity. Most existing FES systems do not automatically modulate stimulation intensity in response to muscle fatigue, and may overstimulate the muscles if fixed (open-loop) stimulation or a pure feedback-based stimulation strategy is used to control FES intensity. To address this limitation, the researchers aim to develop and clinically test FES for improving stroke gait using data-driven FES control systems.
Footdrop is a highly prevalent post-stroke gait deficit, leading to insufficient ankle dorsiflexion during the swing phase of gait, and reducing functional mobility. FES, which is an external application of stimulation to generate muscle contractions during a functional motor task, can achieve muscle force demands during standing and walking, and help persons with stroke and spinal cord injury recover mobility. FES for the correction of footdrop is one of the most popular gait applications of FES, which has been shown to improve mobility and reduce falls.
Although FES has positive effects on walking function, elicits active muscle contractions, and enhances corticomotor excitability, FES is not used as commonly as passive orthotics. Most current FES systems incorporate motion sensors to control the timing of FES during the gait cycle (paretic leg swing phase). However, none of these systems provide automatic closed-loop control of FES intensity, so that optimal stimulation can be delivered for each step, preventing over-stimulation, reducing fatigue, and maintaining optimal muscle performance for a greater number of steps. Additionally, rapid onset of muscle fatigue during FES is caused by synchronous, non-selective, repeated recruitment of largely fatigable muscle fibers.
The researchers will implement an innovative model-predictive controller (MPC) combined with real-time ultrasound-based feedback to deliver optimal FES intensities and minimize fatigue.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| MPC FES Followed by Conventional FES | Experimental | Post-stroke participants participating in both treadmill and overground walking trials with the novel model-predictive controller (MPC) functional electrical stimulation (FES) system first and with a conventional functional electrical stimulation (FES) system second. |
|
| Conventional FES Followed by MPC FES | Experimental | Post-stroke participants participating in both treadmill and overground walking trials with a conventional functional electrical stimulation (FES) system first and the novel model-predictive controller (MPC) functional electrical stimulation (FES) system second. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Model-Predictive Controller (MPC) Functional Electrical Stimulation (FES) | Device | The model-predictive controller (MPC) determines the timing and intensity of electrical stimulation delivered for FES. MPC combined with real-time ultrasound-based feedback delivers optimal FES intensities and minimizes fatigue. FES is delivered to the ankle dorsiflexor muscles using a commercially available FDA-approved electrical stimulator. |
| Measure | Description | Time Frame |
|---|---|---|
| Number of Adverse Events | Safety is assessed as the number of adverse events experienced by study participants. | Day 1 |
| Count of Risks | Safety is assessed as the count of risks, including falling, discomfort, pain, skin problems, fatigue, and soreness. | Day 1 |
| Participant Perception of Comfort | Participant perception of comfort is measured on an 10-point Likert scale ranging from 1 to 10, where 10 is the most comfortable. | Day 1 |
| Participant Perception of Acceptability | Participant perception of acceptability is measured on an 10-point Likert scale ranging from 1 to 10, where 10 is the most acceptable. | Day 1 |
| Percent of Gait Cycles with Footdrop Correction | Feasibility of the FES control system is assessed as the percentage of gait cycles with footdrop correction. The FES control system is considered effective if greater than 80% of gait cycles have footdrop correction. | Day 1 |
| Number of Participants Completing Gait Bouts | Feasibility of the FES control system is assessed as the number of participants who are able to complete gait bouts with the MPC FES system. The FES control system is considered effective if greater than 80% of participants are able to complete gait bouts. | Day 1 |
| Measure | Description | Time Frame |
|---|---|---|
| Peak Ankle Dorsiflexion Angle During Swing | Gait biomechanics performance is assessed as the peak ankle dorsiflexion angle during swing. The normal range for peak ankle dorsiflexion is 0 to 5 degrees. | Day 1 |
| Overground Walking Distance |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Trisha Kesar, PT, PhD | Contact | (404) 712-5803 | trisha.m.kesar@emory.edu |
| Name | Affiliation | Role |
|---|---|---|
| Trisha Kesar, PT, PhD | Emory University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Emory Rehabilitation Hospital | Atlanta | Georgia | 30322 | United States |
De-identified individual participant data for primary dependent variables that underlie the results reported in publications from this study (such as text, tables, appendices) will be made available for sharing with other researchers.
Data will be made available for sharing beginning 9 months and for 2 years after publication of the manuscript presenting the study primary results.
Data will be made available for sharing with researchers who provide a methodologically sound proposal to achieve the aims proposed by the requestor. Proposed purposes for using the shared data include replication studies, meta-analyses or systematic reviews, and other special requests. Researchers wanting to use data from this study should direct their requests to tkesar@emory.edu. To gain access, data requestors will need to sign a data access agreement.
Not provided
Not provided
Participants are randomized to the order of the test conditions.
Not provided
Not provided
Not provided
Not provided
|
| Conventional Functional Electrical Stimulation (FES) | Device | For functional electrical stimulation, surface electrodes are placed on the paretic leg on skin overlying the tibialis anterior (TA) muscle, with intensity pre-set to elicit dorsiflexion to neutral against gravity. FES will be delivered to the ankle dorsiflexor muscles using a commercially available FDA-approved electrical stimulator. |
|
Gait performance is assessed as overground walking distance traveled, in meters, during a 6-minute walk test.
| Day 1 |
| FES Intensity | FES system performance is assessed as FES intensity. FES intensity is measured during a treadmill walking bout. Intensity is measured by milliamps (mA) or millivolts (mV). | Day 1 |