Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| NL88635.042.24 | Other Identifier | CCMO |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Endoscopic submucosal dissection (ESD) is a relatively new technique to treat superficial cancers in the upper gastrointestinal (GI) tract. Previous studies reported high en bloc resection rates (95%-97%). However, R0 resection rates (84.5%) suggest that the tumour is not radically removed in all cases, resulting in a risk of tumour recurrence. One of the key challenges is the limited accuracy in determining the depth of cancer invasion. To reduce the risk of tumour recurrence, the endoscopist would greatly benefit from proper and complete visualization of the tumour margin and depth during ESD. Several studies have shown that near-infrared quantified fluorescence molecular endoscopy (qFME) could serve as a red flag detection method and might be a useful imaging tool for tumour demarcation in the upper GI tract. The aim of this study is to evaluate the feasibility of ICG-enhanced near-infrared qFME to determine tumour demarcation and tumour depth in upper GI tumours (e.g. superficial esophageal and/or gastric adenocarcinoma (T1)) during ESD.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Systemic administration of ICG | Experimental | Indocyanine Green (ICG) will be administered systemically 30 minutes before endoscopic submucosal dissection (ESD). Near-infrared quantified fluorescence molecular endoscopy (qFME) will be performed during the procedure. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Indocyanine Green (IC-Green) | Drug | Systemic administration of indocyanine green during the endoscopic procedure. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Feasibility of ICG-enhanced qFME to determine tumour demarcation and depth in upper gastrointestinal tumours during ESD | Feasibility will be assessed by analyzing the fluorescent imaging data obtained during and after the procedure. Visible fluorescence will be determined by calculating the target-to-background ratio (TBR), where the target is defined as the mean pixel intensity of the resection bed in areas displaying fluorescence. | One week after the qFME procedure |
| Feasibility of ICG-enhanced qFME to determine tumour demarcation and depth in upper gastrointestinal tumours during ESD | Secondary evaluation will focus on whether visible fluorescence after resection correlates with an R1 resection grade based on histopathology. | One week after the qFME procedure |
| Feasibility of ICG-enhanced qFME to determine tumour demarcation and depth in upper gastrointestinal tumours during ESD | Fluorescence will also be quantified using mucosal multi-diameter single-fiber reflectance / single-fiber fluorescence (MDSFR/SFF) spectroscopy, a non-invasive measurement technique. | After study completion, to be expected within 8 months |
| Measure | Description | Time Frame |
|---|---|---|
| Visibility of the papilla of Vater and the intraduodenal part of the extrahepatic biliary anatomy by detecting fluorescent signal with ICG-enhanced qFME | Visibility is determined visual evaluation during the endoscopic procedure and calculating the TBR in the same manner as explained above. | One week after the qFME procedure |
Not provided
Inclusion Criteria:
Exclusion Criteria (contraindications for indocyanine green):
Known allergy to indocyanine green;
Known allergies to iodine, shellfish and/or clams;
eGFR < 30 mL/min/1.73 m2;
Pregnancy or breastfeeding;
Hyperthyroidism.
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Wouter B. Nagengast, MD, PharmD, PhD | Contact | +31(0)503612620 | w.b.nagengast@umcg.nl |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University Medical Centre Groningen | Recruiting | Groningen | Provincie Groningen | 9713GZ | Netherlands |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Fluorescence guided identification using indocyanine green | Diagnostic Test | Near-infrared quantified fluorescence molecular endoscopy (qFME) will be used during the endoscopic procedure. |
|
| ID | Term |
|---|---|
| D004938 | Esophageal Neoplasms |
| D013274 | Stomach Neoplasms |
| ID | Term |
|---|---|
| D005770 | Gastrointestinal Neoplasms |
| D004067 | Digestive System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
| D006258 | Head and Neck Neoplasms |
| D004066 | Digestive System Diseases |
| D004935 | Esophageal Diseases |
| D005767 | Gastrointestinal Diseases |
| D013272 | Stomach Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D007208 | Indocyanine Green |
| ID | Term |
|---|---|
| D007211 | Indoles |
| D006574 | Heterocyclic Compounds, 2-Ring |
| D000072471 | Heterocyclic Compounds, Fused-Ring |
| D006571 | Heterocyclic Compounds |
Not provided
Not provided