The study aims to evaluate the effectiveness of the novel Real-Time Continuous Glucose Monitoring (RT-CGM) system "Glunovo" in improving glycemic control and patient-reported outcomes in individuals with poorly controlled Type 2 Diabetes (T2D).
This is a prospective, open-label, randomized controlled trial involving 165 adult patients with T2D recruited at the Fatebenefratelli-Sacco Hospital in Milan. Participants were randomized in a 1:1 ratio to either the intervention group (RT-CGM with Glunovo) or the control group (standard Self-Monitoring of Blood Glucose [SMBG] using conventional glucometers).
The primary outcome is the change in Glycated Hemoglobin (HbA1c) levels after 6 months of follow-up. Secondary outcomes include Continuous Glucose Monitoring (CGM)-derived metrics-such as Glucose Management Indicator (GMI), Time in Range (TIR), Time Above Range (TAR), and Time Below Range (TBR)-as well as patient well-being, assessed using the WHO-5 Well-Being Index and a satisfaction scale.
The study is designed to assess whether the Glunovo RT-CGM system can support better metabolic control and improve patient experience compared to conventional SMBG methods.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| subjects who will use the device object of the interventional study | Experimental | Participants randomized to this arm used the Glunovo Real-Time Continuous Glucose Monitoring (RT-CGM) system for 6 months. |
|
| subjects who will use their glucometer (control group) | Placebo Comparator | Capillary glucose monitoring using fingerstick glucometer as per standard care. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Glunovo CGM device | Device | Group 1 (Subjects that will use Glunovo CGM device) will be compared to Group 2 (subject that will use their glucometer) |
|
| Measure | Description | Time Frame |
|---|---|---|
| changes in HbA1c levels | The primary outcome of the study was to evaluate changes in HbA1c levels after 6 months of RT-CGM use compared to baseline in both the intervention and control groups | 6 months |
Not provided
Not provided
Inclusion Criteria:
Diagnosis of Type 2 Diabetes (T2D) Age above 18 years Glycated Hemoglobin (HbA1c) between 7.5% and 11% On basal-bolus insulin, basal-oral combination therapy, or non-insulin antidiabetic therapy
Exclusion Criteria:
Pregnancy HbA1c > 11% or < 7.5% Diagnosis of Type 1 Diabetes, Latent Autoimmune Diabetes in Adults (LADA), Maturity Onset Diabetes of the Young (MODY), or other forms of hyperglycemia
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Prof. Paolo Fiorina | University of Milan | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| ASST Sacco Fatebenefratelli | Milan | Milan | 20154 | Italy |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 41551204 | Derived | Lazzaroni E, Cimino V, Gandolfi A, Tinari C, Bucciarelli L, Morpurgo P, Ben Nasr M, Fiorina RM, Pastore I, Baruffaldi L, Losurdo F, D'Addio F, Zuccotti GV, Montefusco L, Rossi A, Lunati ME, Fiorina P. A Randomized Study of the Glunovo Real-time CGM Effectiveness in Individuals With Poorly Controlled Type 2 Diabetes. J Endocr Soc. 2026 Jan 12;10(2):bvaf165. doi: 10.1210/jendso/bvaf165. eCollection 2026 Feb. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003924 | Diabetes Mellitus, Type 2 |
| ID | Term |
|---|---|
| D003920 | Diabetes Mellitus |
| D044882 | Glucose Metabolism Disorders |
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| BG-meter | Device | BG-meter |
|
| D004700 | Endocrine System Diseases |