This multicenter, parallel-group, randomized controlled trial (RELEASE) aims to evaluate the efficacy of two educational approaches on acceptance and adherence to intermittent catheterization (IC) among adult male patients. Participants requiring IC training will be randomized to either an enhanced educational intervention (informational booklet, video tutorial, and standard training) or standard clinical practice training alone. The primary outcome is the change in Intermittent Catheterization Acceptance Test (I-CAT) scores over three months. Secondary outcomes include adherence (I-CAS), urinary symptoms (USQNB-IC), patient autonomy, satisfaction with assistive technology (QUEST), and functional abilities. The study seeks to identify the most effective educational strategy to improve psychological acceptance, promote adherence, and reduce complications in patients performing IC, ultimately supporting patient-centered care and health system efficiency.
This multicenter, randomized controlled trial (RELEASE study) investigates the effectiveness of two different educational approaches to improve acceptance and adherence to intermittent catheterization (IC) among adult male patients who require IC training. Participants will be randomly assigned to one of two groups: an intervention group receiving an enhanced educational program (including an informational booklet, video tutorial, and standard clinical training) and a control group receiving only standard clinical practice training.
The study will enroll adult male patients with an indication for self-managed intermittent catheterization and who are physically and cognitively able to learn IC techniques. The primary outcome measure is the change in Intermittent Catheterization Acceptance Test (I-CAT) scores at three months (T2) compared to baseline (T0).
Secondary outcomes include adherence measured using the Intermittent Catheterization Adherence Scale (I-CAS), urinary symptoms evaluated with the USQNB-IC, patient autonomy, satisfaction with assistive technology (QUEST 2.0), and overall functional abilities. Additional data such as socio-demographic characteristics and medical history will also be collected.
The trial seeks to provide evidence on the most effective educational strategy to support psychological acceptance and sustained adherence to IC, reduce complications, and promote greater patient autonomy. By addressing educational gaps, the study aims to enhance patient-centered care and optimize resource use within the healthcare system.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Enhanced Educational Program for Intermittent Catheterization | Experimental | Participants in this arm will receive an enhanced educational intervention comprising an informational booklet, a video tutorial specifically designed for self-managed intermittent catheterization (IC), and standard clinical practice training. This comprehensive approach aims to improve psychological acceptance, adherence, and self-efficacy in performing IC |
|
| Standard Education Group | Active Comparator | Participants receive standard clinical practice training for self-managed intermittent catheterization (IC) as typically provided in routine care settings. This arm serves as the active comparator to evaluate the additional impact of the enhanced educational intervention. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Enhanced Educational Program for Intermittent Catheterization | Other | Participants in this group receive an enhanced educational program for intermittent catheterization (IC), including an informational booklet, a specifically designed video tutorial, and standard clinical practice training. The program aims to improve psychological acceptance, adherence, and self-efficacy by providing comprehensive and patient-centered educational materials in addition to standard care. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in Intermittent Catheterization Acceptance (I-CAT) Score | Change in psychological acceptance of intermittent catheterization measured using the Intermittent Catheterization Acceptance Test (I-CAT). The I-CAT assesses acceptance attitudes toward IC, including psychological readiness and emotional adaptation. Higher scores indicate greater acceptance. | Baseline (T0) to 3 months (T2) |
| Measure | Description | Time Frame |
|---|---|---|
| Adherence to Intermittent Catheterization (I-CAS Score) | Adherence to intermittent catheterization practices measured by the Intermittent Catheterization Adherence Scale (I-CAS). The scale evaluates the frequency and consistency of IC behaviors. Higher scores indicate greater adherence. | Baseline (T0) to 3 months (T2) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Only individuals who identify as male and correspond to the biological sex assigned at birth (male) are eligible to participate in this study.
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Stefania Musco, MD | Contact | +39 3476383462 | muscos@aou-careggi.toscana.it |
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35102733 | Background | Vecchio M, Chiaramonte R, DI Benedetto P. Management of bladder dysfunction in multiple sclerosis: a systematic review and meta-analysis of studies regarding bladder rehabilitation. Eur J Phys Rehabil Med. 2022 Jun;58(3):387-396. doi: 10.23736/S1973-9087.22.07217-3. Epub 2022 Feb 1. | |
| 35899532 | Background | van der Woude DR, Ruyten T, Bartels B. Reliability of Muscle Strength and Muscle Power Assessments Using Isokinetic Dynamometry in Neuromuscular Diseases: A Systematic Review. Phys Ther. 2022 Oct 6;102(10):pzac099. doi: 10.1093/ptj/pzac099. |
Not provided
Not provided
Given the nature of your intervention (behavioral educational intervention on intermittent catheterization) and local privacy considerations, individual participant data (IPD) will not be shared publicly.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D016055 | Urinary Retention |
| ID | Term |
|---|---|
| D014555 | Urination Disorders |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
Not provided
Not provided
This is a multicenter, parallel-group, randomized controlled trial with two arms. Participants are randomized 1:1 to either an enhanced educational intervention group (informational booklet, video, and standard training) or a control group receiving standard training only. The parallel design allows for direct comparison of outcomes between these two educational strategies.
Not provided
Not provided
Not provided
Not provided
|
| Standard Education Group | Other | Participants in this group will receive standard clinical practice training for intermittent catheterization (IC), as routinely provided in participating healthcare centers. This training focuses on basic procedural skills and practical education necessary to perform IC independently, without additional enhanced educational materials such as booklets or video tutorials. |
|
| Urinary Symptoms Severity (USQNB-IC) |
Severity of urinary symptoms measured by the Urinary Symptom Questionnaire for Neurogenic Bladder-Intermittent Catheterization (USQNB-IC). This assesses frequency and severity of symptoms related to bladder dysfunction and catheterization. |
| Baseline (T0) to 3 months (T2) |
| Patient Autonomy Level | Self-reported autonomy in performing intermittent catheterization, assessed through specific questions evaluating confidence and independence in IC management. | Baseline (T0) to 3 months (T2) |
| Satisfaction with Assistive Technology (QUEST 2.0) | Satisfaction with assistive technology measured using the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0). Higher scores reflect greater satisfaction with IC-related aids and support tools. | 3 months (T2) |
| Overall Functional Abilities | Changes in overall functional abilities assessed through patient self-reports on mobility, self-care, and daily activities impacted by IC. | Baseline (T0) to 3 months (T2) |
| 29990375 | Background | Tractenberg RE, Groah SL, Rounds AK, Ljungberg IH, Schladen MM. Preliminary validation of a Urinary Symptom Questionnaire for individuals with Neuropathic Bladder using Intermittent Catheterization (USQNB-IC): A patient-centered patient reported outcome. PLoS One. 2018 Jul 10;13(7):e0197568. doi: 10.1371/journal.pone.0197568. eCollection 2018. |
| 29956001 | Background | Tornic J, Panicker JN. The Management of Lower Urinary Tract Dysfunction in Multiple Sclerosis. Curr Neurol Neurosci Rep. 2018 Jun 28;18(8):54. doi: 10.1007/s11910-018-0857-z. |
| 1775361 | Background | Sutton G, Shah S, Hill V. Clean intermittent self-catheterisation for quadriplegic patients--a five year follow-up. Paraplegia. 1991 Oct;29(8):542-9. doi: 10.1038/sc.1991.78. |
| 23479547 | Background | Reuben DB, Magasi S, McCreath HE, Bohannon RW, Wang YC, Bubela DJ, Rymer WZ, Beaumont J, Rine RM, Lai JS, Gershon RC. Motor assessment using the NIH Toolbox. Neurology. 2013 Mar 12;80(11 Suppl 3):S65-75. doi: 10.1212/WNL.0b013e3182872e01. |
| 32760189 | Background | Milligan J, Goetz LL, Kennelly MJ. A Primary Care Provider's Guide to Management of Neurogenic Lower Urinary Tract Dysfunction and Urinary Tract Infection After Spinal Cord Injury. Top Spinal Cord Inj Rehabil. 2020 Spring;26(2):108-115. doi: 10.46292/sci2602-108. |
| 20882676 | Background | Manack A, Motsko SP, Haag-Molkenteller C, Dmochowski RR, Goehring EL Jr, Nguyen-Khoa BA, Jones JK. Epidemiology and healthcare utilization of neurogenic bladder patients in a US claims database. Neurourol Urodyn. 2011 Mar;30(3):395-401. doi: 10.1002/nau.21003. Epub 2010 Sep 29. |
| 4810761 | Background | Lapides J, Diokno AC, Lowe BS, Kalish MD. Followup on unsterile intermittent self-catheterization. J Urol. 1974 Feb;111(2):184-7. doi: 10.1016/s0022-5347(17)59922-x. No abstract available. |
| 29953666 | Background | Guinet-Lacoste A, Charlanes A, Chesnel C, Blouet E, Tan E, Le Breton F, Amarenco G. Intermittent Catheterization Adherence Scale (ICAS): A new tool for the evaluation of patient adherence with clean intermittent self-catheterization. Neurourol Urodyn. 2018 Nov;37(8):2753-2757. doi: 10.1002/nau.23746. Epub 2018 Jun 28. |
| 37910578 | Background | Fitzpatrick MA, Solanki P, Wirth M, Weaver FM, Suda KJ, Burns SP, Safdar N, Collins E, Evans CT. Perceptions, experiences, and beliefs regarding urinary tract infections in patients with neurogenic bladder: A qualitative study. PLoS One. 2023 Nov 1;18(11):e0293743. doi: 10.1371/journal.pone.0293743. eCollection 2023. |
| 38454065 | Background | Fitzpatrick MA, Solanki P, Wirth M, Weaver FM, Suda KJ, Burns SP, Safdar N, Collins E, Evans CT. Knowledge, perceptions, and beliefs about urinary tract infections in persons with neurogenic bladder and impacts on interventions to promote person-centered care. Spinal Cord. 2024 May;62(5):221-227. doi: 10.1038/s41393-024-00972-z. Epub 2024 Mar 7. |
| 34501357 | Background | Blanc BF, Rodriguez-Almagro J, Lorenzo-Garcia C, Alcaraz-Zomeno E, Fernandez-Llorente G, Baixauli-Puig M, Martin-Bermejo MV, Estudillo-Gonzalez F, Ortega-Checa MA, Lluesma-Martinez V, Ferrandez-Franco G, Benito-Santos B, Rodriguez-Diaz M, Torres-Bacete A, Guerrero-Andrades MC, Louis-Lauture MP, Jimenez-Mayorga I, Serrano-Abielar R, Garrido-Mora MA, Barcia-Barrera F, Asensio-Malo G, Morcillo-Marin M, Tendero-Ruiz S, Hernandez-Martinez A. Quality of Life and Autonomy in Patients with Intermittent Bladder Catheterization Trained by Specialized Nurses. J Clin Med. 2021 Aug 30;10(17):3909. doi: 10.3390/jcm10173909. |
| 36655638 | Background | Berardi A, Marquez MA, Ottone L, Ruotolo I, Panuccio F, Tofani M, Gonzalez-Bernal J, Galeoto G. Italian translation, cultural adaptation, and validation of the Intermittent Catheterization Acceptance Test (I-CAT). Clin Ter. 2023 Jan-Feb;174(1):8-13. doi: 10.7417/CT.2023.5002. |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |