After more than a decade of development, transcatheter aortic valve replacement (TAVR) is now a standard, guideline-recommended treatment for all symptomatic patients with severe aortic stenosis, regardless of their surgical risk. However, stroke remains a risk for these patients after TAVR. Given its severe impact-significantly increasing post-procedure mortality and severely affecting quality of life-preventing TAVR-related stroke is an urgent problem we need to solve.
The Sentinel Cerebral Protection Device is a percutaneous dual-filter brain protection system. During the procedure, the Sentinel device's filters capture blood clots and tissue debris. After the operation, the captured clots and debris are removed from the body along with the device. Its safety and effectiveness have been validated. Therefore, this project plans to conduct a multi-center registry clinical study to:
Develop a widespread neurological risk prediction model. Create a strict, standardized prevention protocol. Boost awareness of perioperative stroke prevention during TAVR. Provide practical clinical experience. By doing so, we aim to better prevent strokes in patients undergoing TAVR.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Sentinel® Cerebral Protection System | Device | Deploy a Sentinel cerebral protection device during TAVR for patient with aortic stenosis. | ||
| MRI | Diagnostic Test | Patients receive head MRI before and after the surgery in order to determine the stroke incidence. |
| Measure | Description | Time Frame |
|---|---|---|
| The Rate of Stroke Through 72 Hours Post TAVR Procedure or Discharge (Whichever Comes First) | All stroke (hemorrhagic, ischemic, or undetermined status; disabling or nondisabling) through 72 hours post TAVR procedure or discharge (whichever comes first), as adjudicated by an independent Clinical Events Committee (CEC) and using Neurologic Academic Research Consortium (NeuroARC) definitions. | From enrollment to 72 hours post surgery or discharge (whichever comes first) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
History of previous open-chest surgery or previous heart valve replacement. Patients with left ventricular ejection fraction ≤ 30%. Presence of contraindications for MRI examination. Patients with claustrophobia. Patients unable to comply with follow-up.
Not provided
Not provided
Not provided
Patients in China
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Yongquan Xie | Chinese Academy of Medical Sciences, Fuwai Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Fuwai Hospital | Beijing | China |
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D020521 | Stroke |
| ID | Term |
|---|---|
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided