The number of implantable cardiac rhythm devices is increasing. As a result, the number of patients requiring lead extraction is increasing. In this study, authors aimed to present their experience with lead extraction using manual traction.
Objectives: The number of implantable cardiac rhythm devices is increasing. As a result, the number of patients requiring lead extraction is increasing. In this study, authors aimed to present our experience with lead extraction using manual traction.
Methods: Patients (n=130) who underwent lead extraction by manual traction without the use of lead extraction devices (extraction sheaths, locking stylets, etc.) manufactured for extraction at our hospital between 2016 and 2021 were reviewed. Patient characteristics, indications for extraction, procedural success, complications, and mortality were evaluated.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Manual traction | Other | The pacemaker or ICD lead extraction with manually. |
| Measure | Description | Time Frame |
|---|---|---|
| Extraction the pacemaker or ICD lead manually without complication. | The patients number of extraction of all lead and pacemaker generator components without major complications was defined as procedural success. | one month |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Patients who underwent transvenous lead extraction manually in our hospital.
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 28919379 | Background | Kusumoto FM, Schoenfeld MH, Wilkoff BL, Berul CI, Birgersdotter-Green UM, Carrillo R, Cha YM, Clancy J, Deharo JC, Ellenbogen KA, Exner D, Hussein AA, Kennergren C, Krahn A, Lee R, Love CJ, Madden RA, Mazzetti HA, Moore JC, Parsonnet J, Patton KK, Rozner MA, Selzman KA, Shoda M, Srivathsan K, Strathmore NF, Swerdlow CD, Tompkins C, Wazni O. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart Rhythm. 2017 Dec;14(12):e503-e551. doi: 10.1016/j.hrthm.2017.09.001. Epub 2017 Sep 15. No abstract available. | |
| 29566158 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Background |
| Bongiorni MG, Burri H, Deharo JC, Starck C, Kennergren C, Saghy L, Rao A, Tascini C, Lever N, Kutarski A, Fernandez Lozano I, Strathmore N, Costa R, Epstein L, Love C, Blomstrom-Lundqvist C; ESC Scientific Document Group. 2018 EHRA expert consensus statement on lead extraction: recommendations on definitions, endpoints, research trial design, and data collection requirements for clinical scientific studies and registries: endorsed by APHRS/HRS/LAHRS. Europace. 2018 Jul 1;20(7):1217. doi: 10.1093/europace/euy050. No abstract available. |