Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
With the changes in medical models and improvements in people's quality of life, parturients have higher demands for childbirth, making the alleviation and elimination of labor pain an important aspect of modern obstetrics. Intrathecal labor analgesia has been widely adopted in clinical practice to relieve pain. However, current studies mainly focus on parturients who are just beginning to receive labor analgesia, while for those experiencing prolonged analgesia, medical institutions still use traditional formulations, lacking relevant guidelines or expert consensus. In such cases, prolonged waiting and anxiety may lower the pain tolerance of parturients, leading to an increased need for higher concentrations of local anesthetics. To address this clinical gap, this study aims to explore the effects of different concentrations of ropivacaine in prolonged labor analgesia and has designed a prospective randomized controlled trial (RCT) to provide evidence for improving the analgesic regimen for this group of parturients.
Background:
With changes in medical models and improvements in quality of life, parturients have higher expectations for childbirth, making the alleviation and elimination of labor pain an important aspect of modern obstetrics. Intrathecal labor analgesia is widely used in clinical practice to relieve labor pain. However, studies on prolonged labor analgesia, especially following the replacement of the first analgesic pump, are scarce. Medical institutions often continue to use traditional analgesic formulations without relevant guidelines or expert consensus. Prolonged analgesia may reduce pain tolerance in parturients, possibly necessitating adjustments in local anesthetic concentration to improve analgesic effectiveness. Given the clinical research gap, this study aims to explore the effects of different concentrations of ropivacaine on prolonged labor analgesia and its impact on maternal and neonatal safety.
Objective:
To investigate the effects and maternal-neonatal safety of using different concentrations of ropivacaine for prolonged labor analgesia, providing clinical evidence for optimizing labor analgesia regimens.
Methods:
This single-center prospective randomized controlled study will collect clinical data from parturients receiving labor analgesia at Chengdu Jinjiang District Maternal and Child Health Hospital from May to August 2025. Participants meeting the inclusion and exclusion criteria will be included. Following the replacement of the first analgesic pump, parturients will be randomly assigned to receive one of two ropivacaine concentration regimens (Group H: 0.12% ropivacaine; Group N: 0.1% ropivacaine). Data collection will include demographic information, pain scores, labor-related parameters, neonatal outcomes, and adverse reactions.
Interventions:
Primary Outcome:
Pain scores at different time points (T0: at pump replacement; T1: 0.5 hours after pump replacement; T2: 1 hour after pump replacement; T3: at full cervical dilation or during transition to cesarean section).
Secondary Outcomes:
Hypothesis:
Different concentrations of ropivacaine for prolonged intrathecal labor analgesia will have varying effects on pain control and maternal-neonatal safety, with higher concentration ropivacaine (0.12%) likely being more effective in pain relief, while both concentrations are expected to show no significant difference in maternal and neonatal safety.
Ethics Approval:
This study has received approval from the ethics committee of Chengdu Jinjiang District Maternal and Child Health Hospital (Approval Number: 202312). All participants must sign an informed consent form to ensure the respect of participant rights and data confidentiality. The study will strictly adhere to relevant ethical standards and legal regulations to protect participant safety and privacy.
Funding:
This study is funded by the following projects:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| high concentration ropivacaine group | Experimental | The combination of 0.12% ropivacaine and 0.5 μg/ml sufentanil |
|
| Low concentration ropivacaine group. | Active Comparator | The combination of 0.1% ropivacaine and 0.5 μg/ml sufentanil |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| High-concentration Ropivacaine | Drug | After the first pump fluid is depleted, switch to 0.12% ropivacaine to continue labor analgesia. |
|
| Measure | Description | Time Frame |
|---|---|---|
| Visual Analog Scale (VAS) Pain Score | The pain will be assessed using the Visual Analog Scale (VAS) at four time points: T0 (at the time of pump fluid change) T1 (0.5 hours after the pump fluid change) T2 (1 hour after the pump fluid change) T3 (when full cervical dilation is achieved/in case of emergency cesarean section). | From pump replacement to the end of labor analgesia. |
| Measure | Description | Time Frame |
|---|---|---|
| Modified Bromage score | The level of motor blockade will be assessed using the Modified Bromage Score at four time points: T0 (at the time of pump fluid replacement) T1 (0.5 hours after the pump fluid replacement) T2 (1 hour after the pump fluid replacement) T3 (at full cervical dilation/in case of emergency cesarean section) | From pump replacement to the end of labor analgesia. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
This study is open to women who are planning a vaginal delivery and voluntarily accepting labor analgesia.
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Bo Liu, MS | Contact | +8618502846036 | liubojjfy@163.com | |
| Fei Jia, MD | Contact | +8618581877655 | jiafei1980@sina.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Chengdu Jinjiang District Women & Children Health Hospital, | Chengdu | Sichuan | 610011 | China |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35443838 | Result | Jian Z, Longqing R, Dayuan W, Fei J, Bo L, Gang Z, Siying Z, Yan G. Prolonged duration of epidural labour analgesia decreases the success rate of epidural anaesthesia for caesarean section. Ann Med. 2022 Dec;54(1):1112-1117. doi: 10.1080/07853890.2022.2067353. | |
| 35281318 | Result | Ni JX, Feng JL, Yao SJ, Ni LF, Song SB, Song CZ, Qian XW, Mei Z, Yu J. Determination of the Dose-Response Relationship of Epidural Dexmedetomidine Combined with Ropivacaine for Labor Analgesia. Drug Des Devel Ther. 2022 Mar 6;16:609-618. doi: 10.2147/DDDT.S346842. eCollection 2022. |
| Label | URL |
|---|---|
| Related Info | View source |
Not provided
For our study "Effects of Different Concentrations of Ropivacaine on Prolonged Labor Analgesia," we have decided not to share Individual Participant Data (IPD). This decision is due to privacy concerns, data security requirements, ethical approval limitations, legal restrictions, and the study's design which did not accommodate data sharing. We believe this aligns with ethical standards and operational capabilities.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
A double-blind design is a research method aimed at eliminating bias between participants and researchers. In this design, participants are randomly assigned to different intervention groups (such as different concentrations of ropivacaine), and neither the participants nor the researchers responsible for evaluating the results are aware of the specific group allocations. This ensures the objectivity and reliability of the research findings, avoiding the influence of subjective expectations or observational biases on data interpretation.
| Low concentration ropivacaine group | Drug | After the first pump fluid is depleted, switch to 0.12% ropivacaine to continue labor analgesia. |
|
| Mode of delivery | The mode of delivery will be recorded (vaginal birth/cesarean section). | At the end of delivery |
| Neonatal Apgar score | The Apgar Score will be recorded for the newborn at 1 minute, 5 minutes, and 10 minutes after delivery. | 10 minutes after the delivery of the fetus |
| nausea and vomiting questionnaire | Nausea and vomiting will be recorded if they occur after changing the infusion until the end of delivery. | From pump replacement to the end of labor analgesia. |
| 35157756 | Result | Tan HS, Reed SE, Mehdiratta JE, Diomede OI, Landreth R, Gatta LA, Weikel D, Habib AS. Quality of Labor Analgesia with Dural Puncture Epidural versus Standard Epidural Technique in Obese Parturients: A Double-blind Randomized Controlled Study. Anesthesiology. 2022 May 1;136(5):678-687. doi: 10.1097/ALN.0000000000004137. |
| 20410515 | Result | Hawkins JL. Epidural analgesia for labor and delivery. N Engl J Med. 2010 Apr 22;362(16):1503-10. doi: 10.1056/NEJMct0909254. No abstract available. |