This study is designed as a multicenter, prospective, controlled, randomized, two-arms, cross-over, two parallel cohorts, efficacy Clinical research with CE-marked medical device . The crossover trial will be performed in a blind fashion, so each participant will be evaluated during both blinded pacing-on and pacing-off phases, each of which will last 3 months. The population includes patients with the diagnosis of stable HFpEF according to criteria of the European Society of Cardiology and New York Heart Association (NYHA) functional class II-III/IV, left ventricular hypertrophy with small ventricular volume, sinus rhythm with low basal heart rate and chronotropic incompetence (CI).
All patients will undergo pacemaker implantation, and computer-generated randomization sequence previously designed will be used to allocate participants (in a 1:1 ratio) to receive: (a) programming of the pacemaker with pacing On followed by pacing Off in two periods of 3 months; or (b) programming of the pacemaker with pacing Off followed by pacing On in two periods of 3 months. The study will be conducted in three centers in Spain. Discounting the time due to staggered entry, the total duration of a patient's follow-up will be 7 months.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Pacing on | Experimental | Pacemarker stimulation programmed as AAIR / DDDR / VVIR with the basic stimulation frequency and the rate response as follows (pacing on):
|
|
| Pacing off | Placebo Comparator | VVI 30 bpm |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dual-chamber cardiac pacemaker (Essentio MRI L111 Boston Scientific®), Single-chamber cardiac pacemaker (Essentio MRI L110 Boston Scientific®) | Device | Dual-chamber cardiac pacemaker (Essentio MRI L111 Boston Scientific®), with rate-adaptive pacing of the right atrium. There will be an associated right atrial lead (INGEVITY™ MRI Pacing Lead Boston®) and right ventricular lead (INGEVITY™ MRI Pacing Lead Boston®). Single-chamber cardiac pacemaker (Essentio MRI L110 Boston Scientific®), with rate-adaptive pacing of the ventricles. There will be a right ventricular lead (INGEVITY™ MRI P Boston®). |
| Measure | Description | Time Frame |
|---|---|---|
| Peak oxygen uptake | The primary endpoint of the study is absolute and relative changes in peak oxygen uptake (peakVO2) after three months of pacemaker stimulation. | 3 months after the pacemarker stimulation |
| Measure | Description | Time Frame |
|---|---|---|
| Minnesota Living with Heart Failure Questionnaire (MLHFQ) | Absolute changes in quality of live assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ) | From randomization until the end of study in month 7 |
| E/E' ratio |
| Measure | Description | Time Frame |
|---|---|---|
| Acute HF hospitalizations | Total number of episodes of acute HF hospitalizations. | From baseline until the end of study in month 7 |
| Worsening HF not requiring hospitalization | Total episodes of worsening HF not requiring hospitalization |
Inclusion Criteria:
Stable symptomatic heart failure (NYHA functional class ≥II) during the last month.
Diagnosis criteria of HFpEF according to ESC guidelines:
Left ventricular hypertrophy was defined as wall thickness > 10 mm.
Small ventricular volume was defined as indexed left ventricular end diastolic volume < 45 ml/m2.
Adults ≥18 years old.
Previous admission for acute heart failure.
Chronotropic incompetence assessed by CPET, defined as: [(HRmax - HRrest)]/[(220 - age) - (HRrest)] < 0.62.
Resting heart rate < 65 bpm in sinus rhythm or 70 bmp in atrial fibrillation.
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Julio Núñez, Doctor | Contact | 652856689 | yulnunez@gmail.es | |
| Vicente Bertomeu, Doctor | Contact | vbertog@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Julio Núñez, Doctor | Hospital Clínico Universitario de Valencia | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital Clínico de la Comunidad Valenciana | Recruiting | Valencia | 46010 | Spain |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
Absolute changes in echocardiogram parameters (E/E' ratio)
| From baseline until the end of study in month 7 |
| Left ventricular volume index | Absolute changes in echocardiogram parameters (Left ventricular volume index) | From baseline until the end of study in month 7 |
| Left atrial volume index | Absolute changes in echocardiogram parameters (Left atrial volume index) | From baseline until the end of study in month 7 |
| Pro-B-type natriuretic peptide | Absolute and relative changes in prognostic biomarkers (pro-B-type natriuretic peptide) | From baseline until the end of study in month 7 |
| Serum carbohydrate antigen 125 | Absolute and relative changes in prognostic biomarkers (serum carbohydrate antigen 125). | From baseline until the end of study in month 7 |
| From baseline until the end of study in month 7 |
| Mortality | Mortality | From baseline until the end of study in month 7 |