Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
A multicenter, single-arm, prospective, non-randomized, non-masked study.
The study aims to assess the safety of the Polaris System in assisting surgeons to perform cataract surgery.
The Polaris System is intended to enhance precision and safety over the current standard of care by employing improved stability controls and augmented visualization properties, enabling safer surgical decisions and finer control of surgical instruments.
This study will be conducted at up to 3 research sites. After the informed consent process, potential participants will be considered enrolled in the study and undergo the screening evaluation. Following confirmation of eligibility, selected participants will be sequentially assigned to undergo robot-assisted cataract surgery and receive four scheduled follow-ups over 90 days, post-intervention.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Participants with age-related uncomplicated cataract | Experimental | Single eye cataract robot-assisted cataract surgery. Participants will receive intraoperative eye preparation according to the standard of care for cataract surgery. Under general anesthesia, a docking procedure between the study eye and the medical device will be completed. The surgeon will use the Polaris System to perform initial surgical tasks and perform the initial portion of the affected lens extraction. Finally, the surgeon will use the Polaris System to complete the lens extraction and perform the final surgical tasks, including the intraocular lens implantation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| cataract surgery | Device | Robot-assisted cataract surgery |
|
| Measure | Description | Time Frame |
|---|---|---|
| Rate of safety events | Rate of ocular adverse events in the study eye | 12 weeks |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Pooria Kashani Vice-president of Product | Contact | 908-477-8382 | pkashani@horizonsurgicalsystems.com | |
| Jean-Pierre Hubschman, Chief Executive Officer | Contact | 310-691-9061 | jphubschman@horizonsurgicalsystems.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Clinica Quesada SA de CV | Recruiting | San Salvador | San Salvador Department | El Salvador |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D002387 | Cataract Extraction |
| ID | Term |
|---|---|
| D054140 | Refractive Surgical Procedures |
| D013508 | Ophthalmologic Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| cataract surgery | Device | Robot-assisted cataract surgery, designed to provide superior precision and increase the safety profile of the current standard of care. |
|