Comparing the efficacy of superhigh-flux dialyzer with high-flux dialyzer in ESKD patient who have sepsis to improve mortality and sepsis outcome, an open label randomized control trial.
Sepsis in people who have ESKD is the risk of developing poor outcome. Cytokines play a role in the process of sepsis and cause the worsening clinical outcome despite definitive antibiotic treatment. Superhigh-flux dialyzer has a larger molecular weight cut off (MWCO) clearance, include cytokine, could contribute to improved sepsis management in individuals with ESKD. This study is conducted to prove the efficacy of super high-flux dialyzer comparing with high-flux dialyzer in case of mortality reduction for regular hemodialysis ESKD patients.
Method This study is an open label single center randomized control trial. We randomized ESKD patients who have sepsis condition with high interleukin-6 (IL-6 > 50 pg/ml).
The participants were allocated to super high-flux dialyzer group and high flux dialyzer group, stratified with diabetes, vascular access, and septic shock.
We excluded; patient who needed dialysis with continuous kidney replacement therapy, vulnerable patient, include pregnant woman, patient who closed and patient who expected to pass away within the 24 hours. We aim to enroll total 202 participants; divided equally in each arm. According to our protocol, non reused super high-flux dialyzer and high-flux dialyzer are used in the same assigned patient in first week without crossing over. The standard of care of sepsis and antibiotic are provided in both groups without intervening of researcher and our protocol. The primary endpoint is 28 days of mortality. The secondary outcome include cardiovascular death, rate reduction of IL-6 after dialysis, days of hospitalization, ventilator free days and complication of dialysis are also monitored.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| ESKD patient with sepsis who dialyzed with super high flux | Experimental | Patients received dialysis with Superhigh-flux dialyzer |
|
| ESKD with sepsis who dialyzed with high flux dialyzer | Active Comparator | Patients received dialysis with High-flux dialyzer |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Super High-flux dialyzer (Elisio 19HDx) | Device | Dialysis with Super High-flux dialyzer for intervention group |
|
| Measure | Description | Time Frame |
|---|---|---|
| Comparing the reduction of all cause death at 28 days | Comparing the efficacy to reduce all cause death at 28 days between Super High-flux dialyzer with High-flux dialyzer in ESKD with sepsis | 28 days |
| Measure | Description | Time Frame |
|---|---|---|
| Comparing the difference of blood level of IL-6, ESR, CRP and albumin, before and after of the first dialysis session, in each group. | 7 days | |
| The duration of inotrope weaning | 14 days | |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Punnawit Laungchuaychok, MD | Contact | 022443000 | punnawit@nmu.ac.th | |
| Wanjak Pongsittisak, MD | Contact | 022443000 | wanjak@nmu.ac.th |
| Name | Affiliation | Role |
|---|---|---|
| Punnawit Laungchuaychok, MD | Navamindradhiraj University | Principal Investigator |
| Wanjak Pongsittisak, MD | Navamindradhiraj University | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Navamindhradhiraj university | Recruiting | Dusit | Bangkok | 11130 | Thailand |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 23860248 | Background | Zhou F, Peng Z, Murugan R, Kellum JA. Blood purification and mortality in sepsis: a meta-analysis of randomized trials. Crit Care Med. 2013 Sep;41(9):2209-20. doi: 10.1097/CCM.0b013e31828cf412. | |
| 36044827 | Background | Gharamti AA, Samara O, Monzon A, Montalbano G, Scherger S, DeSanto K, Chastain DB, Sillau S, Montoya JG, Franco-Paredes C, Henao-Martinez AF, Shapiro L. Proinflammatory cytokines levels in sepsis and healthy volunteers, and tumor necrosis factor-alpha associated sepsis mortality: A systematic review and meta-analysis. Cytokine. 2022 Oct;158:156006. doi: 10.1016/j.cyto.2022.156006. Epub 2022 Aug 28. |
| Label | URL |
|---|---|
| Related Info | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Comparing the mortality in sepsis condition between two groups of ESKD patient who underwent hemodialysis with superhighflux and highflux dialyzer
Not provided
Not provided
Not provided
| High-flux dialyzer (Elisio 19H) | Device | Dialysis with High-flux dialyzer for control group |
|
| The duration of hospitalization |
| 28 days |
| Ventilator free days | 28 days |
| The incidence of intradialytic hypotension | 28 days |
| The incidence rate of complication of dialyzer in each group | The incidence rate of complication of dialyzer; allergic reaction, clotting of dialyzer etc. | 28 days |
| The adequacy profile of dialysis in both groups | 7 days |
| 11012910 | Background | Sarnak MJ, Jaber BL. Mortality caused by sepsis in patients with end-stage renal disease compared with the general population. Kidney Int. 2000 Oct;58(4):1758-64. doi: 10.1111/j.1523-1755.2000.00337.x. |
| 31718563 | Background | Song J, Park DW, Moon S, Cho HJ, Park JH, Seok H, Choi WS. Diagnostic and prognostic value of interleukin-6, pentraxin 3, and procalcitonin levels among sepsis and septic shock patients: a prospective controlled study according to the Sepsis-3 definitions. BMC Infect Dis. 2019 Nov 12;19(1):968. doi: 10.1186/s12879-019-4618-7. |
| 35211304 | Background | Abe M, Masakane I, Wada A, Nakai S, Nitta K, Nakamoto H. Super high-flux membrane dialyzers improve mortality in patients on hemodialysis: a 3-year nationwide cohort study. Clin Kidney J. 2021 Sep 28;15(3):473-483. doi: 10.1093/ckj/sfab177. eCollection 2022 Mar. |
| 37231799 | Background | Pongsittisak W, Satpanich P, Jaturapisanukul S, Keawvichit R, Prommool S, Trakranvanich T, Ngamvichukorn T, Kurathong S. Medium Cut-Off versus Low-Flux Dialyzers in Hemodialysis Patients with COVID-19: Clinical Outcomes and Reduction in Interleukin-6. Blood Purif. 2023;52(6):591-599. doi: 10.1159/000530162. Epub 2023 May 5. |
| ID | Term |
|---|---|
| D007676 | Kidney Failure, Chronic |
| D018805 | Sepsis |
| ID | Term |
|---|---|
| D051436 | Renal Insufficiency, Chronic |
| D051437 | Renal Insufficiency |
| D007674 | Kidney Diseases |
| D014570 | Urologic Diseases |
| D052776 | Female Urogenital Diseases |
| D005261 | Female Urogenital Diseases and Pregnancy Complications |
| D000091642 | Urogenital Diseases |
| D052801 | Male Urogenital Diseases |
| D002908 | Chronic Disease |
| D020969 | Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |
| D007239 | Infections |
| D018746 | Systemic Inflammatory Response Syndrome |
| D007249 | Inflammation |
Not provided