This clinical investigation aims to collect data for algorithm development and testing of Vitacam as well as to later validate the system using a simultaneously collected, but segregated, hold-out validation dataset. Vitacam is a software medical device for measuring vital signs, manufactured by NE Device SW Oy. It analyses digital video recorded using a smart device with a camera to locate a subject's face and chest region. From both these regions of interest, the video is further analysed to obtain the heart rate, heartbeat intervals, respiratory rate and oxygen saturation. These measurements are used as inputs to clinical decision making. Vitacam uses remote photoplethysmography to obtain the heart rate and heartbeat intervals, and will build on this to obtain oxygen saturation using information from red-green-blue channels.
The main focus of this study is to validate the oxygen saturation, heart rate and heartbeat intervals measured by Vitacam against gold standard references, applying the ISO 80601:2019 standard.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Desaturation subjects | Other | This is a single arm study where healthy volunteers were subjected to a controlled desaturation protocol to ascertain if the investigational device could correctly track changes in oxygen saturation. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Controlled desaturation | Procedure | A subject rests comfortably on a hospital bed, so that they do not have to move during the desaturation process. The subject wears the altitude simulator head bivy and breathes freely without any oxygen regulation. During the measurement, the time in low O2 saturation plateaus is limited to ten minutes in each desaturation plateau. They are monitored with ECG, clinical pulse oximeter, EtCO2 from non-invasive capnography with nasal cannulas and periodically non-invasive blood pressure. The monitoring is supervised by two medical doctors, present during the entire duration of the study. |
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy of oxygen saturation measurements - Root Mean Square Error | Accuracy as measured by Root Mean Square Error should be less than or equal to 4% for SpO2 as per ISO 80601-2-61:2019. It is calculated from the difference of the SpO2 measured from the investigational device and that of the reference device. | A 30-45 minute period during which the participant is subjected to the de-saturation process |
| Accuracy of oxygen saturation measurements - Mean absolute error | Accuracy as measured by Mean Absolute Error should be less than or equal to 4% for SpO2 as per ISO 80601-2-61:2019. It is calculated from the difference of the SpO2 measured from the investigational device and that of the reference device. | A 30-45 minute period during which the participant is subjected to the de-saturation process |
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy of interbeat intervals of the investigational device against successive R waves of the QRS complex from an Electrocardiogram | To validate the accuracy of Vitacam interbeat intervals, both the intervals and heart rate variability metrics derived from these intervals, will be compared to the RR intervals and heart rate variability metrics derived from a 5-lead ECG | A 30-45 minute period during which the participant is subjected to the de-saturation process |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Tampere University | Tampere | Finland | FI-33014 | Finland |
IPD cannot be shared due to GDPR
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|