Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Liver transplantation is usually associated with hemodynamic instability. TEE allows for a real time monitoring of cardiac structures and has become a standard of care for liver transplant patients. Society of cardiovascular anaesthesia and American society of anaesthesiologists recommends use of TEE in non-cardiac surgery patients with hemodynamic instability. Also, society for advancement of transplant anaesthesia (SATA) has suggested that TEE usage in cases of liver transplant is safe, effective and improves outcomes. TEE can also provide vital information relating to non-cardiac structures including liver, spleen, kidneys, portal vein, hepatic vein and other major vessels. As of now standard protocol is to do the transabdominal doppler for the assessment of portal vein after the liver graft implantation. Hence, the aim of our study is to compare the transesophageal echocardiography and transabdominal Doppler for assessing portal vein in living donor liver transplantation.
Data from all patients who underwent live donor liver transplant surgery at Institute of Liver and Biliary Sciences, New Delhi and in whom TEE probe was inserted will be collected and analysed.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Transesophageal echocardiography | Device | Portal vein velocities were measured using TEE and intraoperative doppler in patients undergoing living donor liver transplantation |
| Measure | Description | Time Frame |
|---|---|---|
| To compare the portal vein flow velocity using transesophageal echocardiography and transabdominal Doppler during live donor liver transplant surgery. | intraoperative period |
| Measure | Description | Time Frame |
|---|---|---|
| any TEE related complication | intraoperative period |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Chronic liver disease
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Gaurav Sindwani, MD | Institute of Liver and Biliary Sciences | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| ILBS | Delhi | 110070 | India |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D017548 | Echocardiography, Transesophageal |
| ID | Term |
|---|---|
| D004452 | Echocardiography |
| D057791 | Cardiac Imaging Techniques |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
Not provided
Not provided
Not provided
Not provided
Not provided
| D003933 | Diagnosis |
| D014463 | Ultrasonography |
| D006334 | Heart Function Tests |
| D003935 | Diagnostic Techniques, Cardiovascular |