Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| M.I.Tech Co., Ltd. | UNKNOWN |
Not provided
Not provided
Not provided
The goal of this prospective, single-center observational study is to evaluate the safety and effectiveness of the HANAROSTEN® HOT Plumber™ with Z-EUSIT™ for draining pancreatic pseudocysts.
The main questions the study aims to answer are:
Participants will:
The study will:
Detailed Description
This prospective, single-center observational study aims to evaluate the safety and effectiveness of the HANAROSTEN HOT Plumber with Z-EUSIT for pancreatic pseudocyst drainage. The study will assess clinical success, defined as a reduction of at least 50% in pseudocyst size accompanied by symptom improvement, as well as technical success, device retention, lumen patency, and adverse events. Follow-up will continue until one month after stent removal.
### Study Rationale
Study Design
Procedure Overview
Follow-Up and Safety Monitoring
Data Collection and Statistical Analysis
Ethical Considerations
This study aims to provide clinical evidence supporting the safety and effectiveness of the HANAROSTEN HOT Plumber with Z-EUSIT for pancreatic pseudocyst drainage, potentially improving outcomes for patients with this condition.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single Intervention Group | Experimental | Participants will undergo endoscopic ultrasound-guided drainage of pancreatic pseudocysts using the HANAROSTEN® HOT Plumber™ with Z-EUSIT™. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| HANAROSTEN® HOT Plumber™ with Z-EUSIT™ | Device | An electrocautery-enhanced lumen-apposing metal stent designed for the drainage of pancreatic pseudocysts. The stent is delivered using a system that allows for single-step deployment without the need for guidewire exchanges or tract dilation. |
| Measure | Description | Time Frame |
|---|---|---|
| Clinical Success | Reduction of pancreatic pseudocyst size by at least 50% with improvement in associated symptoms. | Within 30 or 60 days after stent placement |
| Measure | Description | Time Frame |
|---|---|---|
| Technical Success - Stent Placement | Successful deployment of the stent at the intended site. | During procedure |
| Technical Success - Stent Removal | Successful removal of the stent after pseudocyst resolution, confirmed by endoscopic confirmation of complete stent removal without residual fragments. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Tae Jun Song, MD, PhD | Contact | 82-2-3010-3914 | 82-10-27028163 | medi01@naver.com |
| Yoonchan Lee, MD | Contact | 82-2-3010-1397 | 82-10-86899097 | ycrlee@gmail.com |
| Name | Affiliation | Role |
|---|---|---|
| Dongwook Oh, MD, PhD | Asan Medical Center | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Asan Medical Center | Recruiting | Seoul | Seoul | 05505 | South Korea |
Individual participant data (IPD) will not be shared due to institutional policies and confidentiality regulations.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D010192 | Pancreatic Pseudocyst |
| ID | Term |
|---|---|
| D010181 | Pancreatic Cyst |
| D003560 | Cysts |
| D009369 | Neoplasms |
| D010182 | Pancreatic Diseases |
Not provided
Not provided
The design is non-randomized, with no control or comparison group. The study aims to assess both clinical and technical success, as well as device-related safety outcomes.
Not provided
Not provided
Not provided
Not provided
|
| Within 30 or 60 days after placement |
| Stent Retention | Retention of the stent in the intended location without migration until removal. | Within 30 or 60 days after placement |
| Lumen Patency | Maintenance of an open lumen allowing fluid drainage until stent removal. | Within 30 or 60 days after placement |
| Procedure Duration | Time from initial needle puncture to full deployment of the stent. | During procedure |
| Adverse Events | Incidence of complications such as bleeding, infection, perforation, stent migration, tissue injury, or other adverse events. | From procedure day until one month after stent removal |
| D004066 |
| Digestive System Diseases |