Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Katarzyna Stefaniak Private Practice | UNKNOWN |
Not provided
Not provided
Not provided
The orthodontic mini-implants used in the study are temporary screws inserted into the bone to provide anchorage for challenging tooth movements that could not be carried out using the patient's own teeth. They are made of a medical grade titanium alloy (Ti6Al4Va), with a length of 8 mm and a diameter of 1.3 mm. After the completion of the treatment phase requiring specific anchorage, they are removed and disposed of as a medical waste.
The insertion of the mini-screw is conditioned by the individual treatment plan and the treatment protocol would not differ from the standard treatment.
The aim of the project is to analyze changes in the macrogeometry and wear of the surfaces of retrieved orthodontic micro-implants after their clinical use. Upon completion of clinical tasks, the mini-screws will be removed and retrieved for laboratory phase of the study. The laboratory phase will consist of: microscopic and profilometric examinations, as well as scanning before insertion and after removal of the mini-implants, and a clinical phase: the use of previously scanned and sterilized mini-implants in patients participating in the study.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Test group | Patients seeking for orthodontic treatment with the need of use of the mini-implants |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Insertion | Device | Twenty orthodontic mini-implants (n=20) (AbsoAnchor SH 1312-08, Dentos, Daegu, South Korea) were randomly chosen (every third screw from a sample of 60) numbered consecutively, and embedded in polivynyl siloxane impression material Variotype heavy putty (Kulzer, Hanau, Germany). |
| Measure | Description | Time Frame |
|---|---|---|
| Geometric change | Changes of mini-implant geomtery in micrometers | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Surface analysis | Analysis of irregularities and wear pattern of removed mini-implant | 6 months |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Patients seeking orthodontic treatment with use of the orthodontic mini-implants
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Department of Interdisciplinary Dentistry | Szczecin | West Pomeranian Voivodeship | 70111 | Poland | ||
| Private Dental Practice "Morze Usmiechu" |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 20122438 | Background | Crismani AG, Bertl MH, Celar AG, Bantleon HP, Burstone CJ. Miniscrews in orthodontic treatment: review and analysis of published clinical trials. Am J Orthod Dentofacial Orthop. 2010 Jan;137(1):108-13. doi: 10.1016/j.ajodo.2008.01.027. | |
| 36142951 | Background | Jedlinski M, Janiszewska-Olszowska J, Mazur M, Grocholewicz K, Suarez Suquia P, Suarez Quintanilla D. How Does Orthodontic Mini-Implant Thread Minidesign Influence the Stability?-Systematic Review with Meta-Analysis. J Clin Med. 2022 Sep 9;11(18):5304. doi: 10.3390/jcm11185304. |
Not provided
Not provided
No need.
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D008310 | Malocclusion |
| D008311 | Malocclusion, Angle Class I |
| D008312 | Malocclusion, Angle Class II |
| ID | Term |
|---|---|
| D014076 | Tooth Diseases |
| D009057 | Stomatognathic Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D016254 | Mutagenesis, Insertional |
| D011877 | Radionuclide Imaging |
| ID | Term |
|---|---|
| D015202 | Protein Engineering |
| D005818 | Genetic Engineering |
| D005821 | Genetic Techniques |
| D008919 | Investigative Techniques |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Scanning | Device | After the planned movement is achieved, the mini-implant will be removed and provided to laboratory analysis. All screws were sputtered (0.6µm CaCO₄) and scanned in blue-light technology, using a 3D optical scanner (Atos III, Triple Scan, GOM, Germany) to the nearest 2 micrometres. Due to regularly performed calibration procedures, recommended by the manufacturer, an error study was superfluous. Subsequently, the scans were superimposed using GOM Inspect Software (GOM, Braunschweig, Germany) in order to verify the shape and size repeatability. |
|
| Świnoujście |
| West Pomeranian Voivodeship |
| 72600 |
| Poland |
| 21261491 | Background | Chaimanee P, Suzuki B, Suzuki EY. "Safe zones" for miniscrew implant placement in different dentoskeletal patterns. Angle Orthod. 2011 May;81(3):397-403. doi: 10.2319/061710-111.1. Epub 2011 Jan 24. |
| 19121491 | Background | Eliades T, Zinelis S, Papadopoulos MA, Eliades G. Characterization of retrieved orthodontic miniscrew implants. Am J Orthod Dentofacial Orthop. 2009 Jan;135(1):10.e1-7; discussion 10-1. doi: 10.1016/j.ajodo.2008.06.019. |
| 25836349 | Background | Patil P, Kharbanda OP, Duggal R, Das TK, Kalyanasundaram D. Surface deterioration and elemental composition of retrieved orthodontic miniscrews. Am J Orthod Dentofacial Orthop. 2015 Apr;147(4 Suppl):S88-100. doi: 10.1016/j.ajodo.2014.10.034. |
| 23216058 | Background | Cho IS, Kim TW, Ahn SJ, Yang IH, Baek SH. Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion. Angle Orthod. 2013 Jul;83(4):698-704. doi: 10.2319/082812-689.1. Epub 2012 Dec 10. |
| 20974446 | Background | Francioli D, Ruggiero G, Giorgetti R. Mechanical properties evaluation of an orthodontic miniscrew system for skeletal anchorage. Prog Orthod. 2010;11(2):98-104. doi: 10.1016/j.pio.2010.04.014. Epub 2010 May 15. |
| D009154 |
| Mutation |
| D014644 | Genetic Variation |
| D055614 | Genetic Phenomena |
| D016296 | Mutagenesis |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D003947 | Diagnostic Techniques, Radioisotope |