Post Market Confirmatory Interventional Clinical Study of the Integrity Implant System Used for Rotator Cuff Tear Augmentation
Post Market Confirmatory Interventional Clinical Study of the Integrity Implant System Used for Rotator Cuff Tear Augmentation
The study design is a prospective, multi-center, single-arm, non-randomized post market clinical follow-up study to confirm the performance, safety and clinical benefit of the Integrity Implant System when used for rotator cuff tear augmentation (with or without repair).
The Study Objective is to confirm the performance, safety and clinical benefit of the Integrity Implant System when used for rotator cuff tear augmentation (with or without repair).
The clinical success will be evaluated by absence of rotator cuff re-tear. Performance and clinical benefits will be evaluated by functional outcomes measured using standard scoring systems such as the American Shoulder and Elbow Surgeons Shoulder Score (ASES), Constant-Murley Score (CMS), Patient Satisfaction, EQ-5D-5L, Single Assessment Numeric Evaluation (SANE), Visual Analogue Scale (VAS) and rotator cuff repair outcomes measured using MRI evaluation for repair integrity, quality, tendon tissue thickness and regeneration.
Safety of the Integrity Implant System will be assessed by monitoring the frequency and incidence of adverse events.
The Primary Endpoint shall confirm the Performance of the Integrity Implant System when used for rotator cuff augmentation (with or without repair). Performance will be evaluated by an adequately powered analysis of retear rates seen by MRI at 12-months after surgery.
Index shoulder rotator cuff tendon tear needs management and protection from injury
Index shoulder has no substantial loss of tendon tissue
Index shoulder rotator cuff tendon tear footprint allows approximation of soft tissue and fixation of the Integrity Implant to tendon tissue using an Integrity Tissue Tack
Index shoulder rotator cuff tendon tear footprint allows fixation of the Integrity Implant to bone using the Integrity Bone Staple
Exclusion Criteria
The subject exclusion criteria are as follows:
18.1 Rotator cuff tendon tear is deemed irreparable by the PI
18.2 Rotator cuff tendon tear repair requires replacement of damaged tendon
18.3 Rotator cuff tendon tear repair requires fixation of soft tissue to adjoining soft tissue
18.4 Rotator cuff tendon tear repair requires tendon strength reinforcement
18.5 Presence of infection
18.6 Any condition which would limit the ability or willingness to restrict activities or follow directions during the healing period
18.7 Hypersensitivity to any of the Integrity Implant System components
18.8 Inadequate soft tissue support for Integrity Tissue Tack fixation
18.9 Inadequate quality of bone for Integrity Bone Staple fixation
kmezger@anika.com781-457-9000
jlwilliams@anika.com781-457-9000
Gilbert, Arizona 85234, United States
r.wallace@prgresearch.com800-774-1534
a.fierro@prgresearch.com800-774-1534 ext. 716
Towson, Maryland 21204, United States
jliu@premierortho.org909-596-4346
dwarren@foreonline.org844-944-4263
psimon@foreonline.org844-044-4263
Terri.Brannon@advocatehealth.org762-235-2612
brad_crackel@ciocenter.com317-773-4301
DYocum@sbortho.com574-247-9441 ext. 5199
debbie.codd@comcast.net410-218-4499
Dhoopes@virtua.org856-355-1206 ext. 1206
Kbroderick@virtuahealth.org856-355-1225
Allison.nall@hawkinsfoundation.com864-454-7458
Allyson.sandago@hawkinsfoundation.com864-454-7458
ldelmar@campbell-foundation.org901-759-5495
mknack@campbell-foundation.org901-759-5413