Dysphagia is common and leads to significant morbidity and mortality within healthcare settings. Current approaches to dysphagia management involve altering the consistency of food and fluids. However, these approaches are not supported by a robust evidence base. Repetitive transcranial magnetic stimulation (rTMS) offers a non-invasive way to manipulate neuroelectric activity within the brain. Within the swallowing motor system, rTMS at a frequency of 5Hertz (Hz) and above is excitatory while 1Hz is suppressive.
Cortical rTMS targeting pharyngeal motor areas can alter brain activity and swallowing behaviour in healthy participants and has been shown to improve post-stroke dysphagia (PSD). Despite this, it has a small seizure risk. Cerebellar rTMS is a newer and safer technique which is more easily targeted and is effective at altering swallowing related brain activity and behaviour. Recent studies have also shown it can improve PSD.
Critically, individual responsiveness to rTMS is variable, potentially reducing its effectiveness. Metaplasticity whereby the brain is preconditioned with a neuroelectric stimulus before the treating stimulus is administered is a potential way of reducing variability. Metaplasticity has recently been shown to improve responses within the swallowing motor system following cortical rTMS. However, to date no cerebellar rTMS study has applied this approach. This is a gap in our understanding which will need to be addressed.
The overarching aim of the study is to develop a less variable and more effective treatment for neurogenic dysphagia. More specifically the study objectives are to establish:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Arm 1 | Experimental | 1. Real 10 Hz cerebellar rTMS (250 pulses) to the right cerebellar hemisphere immediately followed by 1 Hz cerebellar rTMS (600 pulses) to the same area. Pharyngeal motor evoked potential (PMEP) amplitude measured |
|
| Arm 2 | Experimental | 2. Sham 10 Hz cerebellar rTMS (250 pulses) to the right cerebellar hemisphere immediately followed by 1 Hz cerebellar rTMS (600 pulses) to the same area. PMEP amplitude measured |
|
| Arm 3 | Experimental | 3. Real 10 Hz cerebellar rTMS (250 pulses) to the right cerebellar hemisphere followed after 45 minutes by 1 Hz cerebellar rTMS (600 pulses) to the same area. PMEP amplitude measured |
|
| Arm 4 | Experimental | 4. Real 10 Hz cerebellar rTMS (250 pulses) to the right cerebellar hemisphere followed after 90 minutes by 1 Hz cerebellar rTMS (600 pulses) to the same area. PMEP amplitude measured |
|
| Arm 5 | Experimental | 5. Real 1 Hz cerebellar rTMS (600 pulses) to the right cerebellar hemisphere immediately followed by 10 Hz cerebellar rTMS (250 pulses) to the same area. PMEP amplitude measured |
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cerebellar rTMS | Device | Cerebellar rTMS applied to pharyngeal area of right hemisphere |
|
| Measure | Description | Time Frame |
|---|---|---|
| Pharyngeal motor evoked potential (PMEP) amplitude | PMEP amplitude measured using single pulse transcranial magnetic stimulation over pharyngeal motor areas of the cortex and cerebellum | 10 measurements made at baseline, 0 minutes post stimulation, 15 minutes post stimulation, 30 minutes post stimulation, 45 minutes post stimulation and 60 minutes post stimulation |
| Swallowing accuracy | Swallowing accuracy measured using a reaction time task | 10 measurements made at baseline, 0 minutes post stimulation, 15 minutes post stimulation, 30 minutes post stimulation, 45 minutes post stimulation and 60 minutes post stimulation |
Not provided
Not provided
Inclusion Criteria:
Healthy participants > 18 years of age
Exclusion Criteria:
Exclusion criteria will be the presence or a history of:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Ayodele Sasegbon | Contact | 0161 789 7373 | ayodele.sasegbon@manchester.ac.uk |
| Name | Affiliation | Role |
|---|---|---|
| Ayodele Sasegbon | University of Manchester | Principal Investigator |
Not provided
No identifiable data pertaining to individual participants will be shared with other researchers
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003680 | Deglutition Disorders |
| ID | Term |
|---|---|
| D004935 | Esophageal Diseases |
| D005767 | Gastrointestinal Diseases |
| D004066 | Digestive System Diseases |
| D010608 | Pharyngeal Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Arm 6 | Experimental | 6. Sham 1 Hz cerebellar rTMS (600 pulses) to the right cerebellar hemisphere immediately followed by 10 Hz cerebellar rTMS (250 pulses) to the same area. PMEP amplitude measured |
|
| Arm 7 | Experimental | 7. Real 1 Hz cerebellar rTMS (600 pulses) to the right cerebellar hemisphere followed after 30 minutes by 10 Hz cerebellar rTMS (250 pulses) to the same area. PMEP amplitude measured |
|
| Arm 8 | Experimental | 8. Real 1 Hz cerebellar rTMS (600 pulses) to the right cerebellar hemisphere followed after 60 minutes by 10 Hz cerebellar rTMS (250 pulses) to the same area. PMEP amplitude measured |
|
| Arm 9 | Experimental | Most excitatory metaplastic protocol (comparing effects of arms 1-8 against one another) to right cerebellar hemisphere. Swallowing accuracy measurements. |
|
| Arm 10 | Experimental | Single dose cerebellar rTMS to right hemisphere. Swallowing accuracy measurements. |
|
| D010038 | Otorhinolaryngologic Diseases |