Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| University of Trieste | OTHER |
Not provided
Not provided
Not provided
The goal of this observational study is to compare, within a cohort of patients requiring rehabilitation in two different sites of the premolar area in the upper maxilla, the primary and secondary stability of implants placed in sites prepared using a magnetic mallet and osseodensification burs.
The primary outcome measures included implant primary stability, assessed through insertion torque and ISQ (Implant Stability Quotient).
Secondary outcome measures were implant secondary stability pattern during the initial 90 days post-implant placement (ISQ), implant survival after one year, the time required for each implant site preparation and any complications or adverse events.
As an additional outcome of this study, we aimed to assess whether there was a relationship between the instrument utilized for implant site preparation and early marginal bone loss. Marginal bone levels were measured at three time points: immediately after surgery (T0), upon delivery of prosthetic rehabilitation (T1), and after one year of loading (T2). The distance between implant platform and bone crest was measured at each time interval, on both mesial and distal aspects of the implant. A positive value was assigned when the bone crest was coronal to the implant platform, whereas a negative value was assigned when the bone crest was apical to the implant platform.
Study design: Observational study of a prospective non-profit cohort.
Study population: The study will be conducted in an outpatient hospital setting.
Sample size calculation: Data from the literature were used regarding insertion torque with the use of the magnetic mallet and osseodensification burs. On average, these data ranged from 50 to 70 Ncm for the magnetic mallet and 35 to 59 Ncm for the osseodensification burs. Using a statistical power of 80%, an alpha error of 0.05, and a beta error of 0.2, the sample size was calculated to be six patients for the experimental group (magnetic mallet - MM) and six patients for the control group (osseodensification burs - OD).
Enrollment procedure: All patients who meet the inclusion and exclusion criteria will be enrolled in the study following the administration of the Information Sheet and the acquisition of informed consent.
Patients seeking implant-supported rehabilitation due to the absence of at least two teeth were evaluated with a periapical radiograph at each selected site to assess the adequacy of residual bone height. If the available bone height appeared to be sufficient, a second-level radiographic exam, a Cone Beam Computed Tomography (CBCT), was performed to evaluate whether the bone volume was adequate for supporting implant rehabilitation.
Surgical phase: After performing local anaesthesia (mepivacaine HCl 2% with epinephrine 1:100,000), a minimally invasive full-thickness flap was elevated. The surgeon, who conducted all the procedures, initiated the first implant site preparation using osteotomes and electrified mallet (Magnetic Mallet, Metaergonomica, Milan, Italy) (test group).
Meanwhile, a second operator began timing the duration of surgery from the initial bone contact of the first osteotome to the placement of the implant.
All the procedures strictly followed the manufacturer's recommendations: initially, a pilot osteotome (100-P) was used. Osteotomes with gradually increasing diameters were employed until the final diameter of 3.2 mm was reached. Subsequently, a 3 mm high transepithelial abutment (OCTA, Megagen, Gyeongbuk, South Korea) was connected to it using a torque wrench and it was tightened to 30 Ncm. Single sutures in monofilament synthetic polypropylene 4.0 were performed to close flaps around the abutment.
Right after the suture of the first surgical site, the site preparation of the control group began.
After performing local anaesthesia (mepivacaine HCl 2% with epinephrine 1:100,000), a minimally invasive full-thickness flap was elevated; the surgeon initiated the preparation using osseodensification burs (Densah, Versah, Jackson, USA). Another operator started timing at the beginning of the procedure and concluded when the implant was placed in the final position.
The experimental sites were prepared using osseodensification burs (Densah, Versah) at a rotation speed of 1200 rpm. The implant beds were equal in dimension and diameter to those prepared with the magnetic hammer, 8.5 mm in height and 3.2 mm in diameter. Subsequently, a 3 mm high transepithelial abutment (OCTA, Megagen, Gyeongbuk, South Korea) was connected to it using a torque wrench and it was tightened to 30 Ncm. Single sutures in monofilament synthetic polypropylene 4.0 were performed to close flaps around the abutment.
After surgery, a radiographic control was conducted to evaluate the correct positioning of the implants.
Once completed, a blinded operator measured ISQ values of each implant from two different directions: vestibular-palatal and mesio-distal.
Each measurement was taken at abutment level three times for each direction, and their averages were used for the statistical analysis.
The values were collected using a Resonance Frequency Analysis (RFA) device (Osstell, Göteborg, Sweden) with the appropriate transducer for the selected abutment (Smartpeg # 74, Osstell, Göteborg, Sweden).
After surgery, a check-up visit was scheduled after one week, when the sutures were removed, soft tissue healing was evaluated, and ISQ was measured as in the first time.
The subsequent check-ups were scheduled at 14 days, 21 days, 28 days, 60 days, 90 days and in each meeting, the same parameters were re-evaluated.
All the implants were restored with screw-retained single metal-ceramic crowns four months after surgery and then followed up for at least for 12 months after prosthetic loading. Two additional check-ups were scheduled for radiographic control after 6 months and 1 year.
Statistical plan: The statistical analysis will be performed by means of a computerized statistical package (SigmaStat 3.5, SPSS Inc., Germany). The data will be expressed as mean ± standard deviation and median (interquartile range), respectively, for parametric and non-parametric values.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Single tooth edentulism right | single missed teeth |
| |
| single tooth edentulism left | single missed tooth |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Implant site preparation with osteotomes and electrified mallet | Procedure | Under local anesthesia (mepivacaine HCL 2% with epinephrine1:100.000), a minimally invasive full-thickness flap was elevated to expose the alveolar crest. A pilot osteotome (100-P) was used to easily perforate the cortical plate. Subsequently, osteotomes with gradually increasing diameters were employed until the final diameter of 3.2 mm was reached. The sequence of osteotomes and their respective diameters were as follows:
A 3 mm high transepithelial abutment (OCTA, Megagen, Gyeongbuk, South Korea) was connected to it using a torque wrench and it was tightened to 30 Ncm. Single sutures in monofilament synthetic polypropylene 4.0 were performed to close flaps around the abutment. |
| Measure | Description | Time Frame |
|---|---|---|
| Implant primary stability | Insertion torque | At implant insertion |
| Implant primary stability | Resonance frequency | At implant insertion |
| Measure | Description | Time Frame |
|---|---|---|
| Implant secondary stability | Resonance frequency | 7 days after implant insertion |
| Implant secondary stability | Resonance frequency | 14 days after implant insertion |
| Measure | Description | Time Frame |
|---|---|---|
| Peri-implant marginal bone level stability | The distance between implant platform and bone crest was measured at each time interval, on both mesial and distal aspects of the implant. A positive value was assigned when the bone crest was coronal to the implant platform, whereas a negative value was assigned when the bone crest was apical to the implant platform. | Immediately after surgery |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
After investigating general and local anamnesis, which included evaluation of systemic illnesses and potential allergies, a dental visit was conducted to formulate a specific treatment plan.
If the patient was deemed eligible for the research protocol, an additional periapical radiograph was obtained for each selected site to assess the adequacy of residual bone height.
If the available bone height appeared to be sufficient, a second-level radiographic exam, a Cone Beam Computed Tomography (CBCT), was performed to evaluate whether the bone volume was adequate for supporting implant rehabilitation.
For patients requiring tooth extraction, this second assessment was performed after six months of healing after extraction.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Piezosurgery Academy | Parma | Italy | 43100 | Italy |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Implant site preparation with osseodensification drills | Procedure | Under local anesthesia (mepivacaine HCL 2% with epinephrine1:100.000), a minimally invasive full-thickness flap was elevated to expose the alveolar crest. The implant site preparation was realized using osseodensification burs at a rotation speed of 1200 rpm. The osseodensification burs sequence was as follows:
A 3 mm high transepithelial abutment (OCTA, Megagen, Gyeongbuk, South Korea) was connected to it using a torque wrench and it was tightened to 30 Ncm. Single sutures in monofilament synthetic polypropylene 4.0 were performed to close flaps around the abutment. |
|
| Implant secondary stability | Resonance frequency | 21 days after implant insertion |
| Implant secondary stability | Resonance frequency | 28 days after implant insertion |
| Implant secondary stability | Resonance frequency | 60 days after implant insertion |
| Implant secondary stability | Resonance frequency | 90 days after implant insertion |
| Surgical time | In seconds | The measurement began when the first pilot osteotome or drill was used and ended when the implant was placed. |
| Peri-implant marginal bone level stability | The distance between implant platform and bone crest was measured at each time interval, on both mesial and distal aspects of the implant. A positive value was assigned when the bone crest was coronal to the implant platform, whereas a negative value was assigned when the bone crest was apical to the implant platform. | Upon delivery of prosthetic rehabilitation (6 months after surgery) |
| Peri-implant marginal bone level stability | The distance between implant platform and bone crest was measured at each time interval, on both mesial and distal aspects of the implant. A positive value was assigned when the bone crest was coronal to the implant platform, whereas a negative value was assigned when the bone crest was apical to the implant platform. | One year of loading |
| ID | Term |
|---|---|
| D009066 | Mouth, Edentulous |
| D016301 | Alveolar Bone Loss |
| ID | Term |
|---|---|
| D009059 | Mouth Diseases |
| D009057 | Stomatognathic Diseases |
| D014076 | Tooth Diseases |
| D001862 | Bone Resorption |
| D001847 | Bone Diseases |
| D009140 | Musculoskeletal Diseases |
| D055093 | Periodontal Atrophy |
| D010510 | Periodontal Diseases |
Not provided
Not provided