Not provided
Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| ethics comittee | Other Identifier | 2497 |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Each eligible patient will be randomly into one of two groups:
Group A: The digital splint group, digital splint will be constructed to each patient.
Group B: The conventional splint group, conventional splint will be constructed to each patient.
The digital splint construction method:
The conventional splint construction method:
The first step is making an impression using a quick-setting addition polyvinyl siloxane impression material. A stone model will be obtained after pouring the impression using extra-hard dental stone.
In the second visit a face bow transfer and a centric relation record will be utilized to mount the casts on a semi adjustable articulator.
For centric relation recording, a jig will be made with an incisal plateau from modeling plastic impression compound and the jig will be inserted between the central incisors. To measure centric relation as precisely as possible (by avoiding translational movement in the temporomandibular joint),
The jig will be adjusted with a scalpel to create a distance of no more than 2 mm between the maxillary and mandibular arches. Then the relation will be recorded using a fast-setting polyvinyl siloxane occlusal registration material. The occlusal registrations will be trimmed to the buccal cusp tips to be transferred accurately to the articulator without interference.
After mounting of the centric relation the protrusive record will be taken and the horizontal condylar angle will be adjusted accordingly.
The device will be fabricated from clear prosthetic resin. Production followed a standardized protocol with a minimum inter maxillary thickness of 1.5 mm and a buccal extension to 1 mm below the survey line.
The device will be finished and occlusion will be adjusted on the articulator. outcomes assessment:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Digitally manufactured occlusal splint | Experimental | digitally manfactured occlusal splint using intra oral scanner and jaw traccking device for data acqusition and 3d printing for manfacturing of the device |
|
| conventionally manufactured occlusal splint | Active Comparator | the occlusal device will be manufactured conventionally using impression and and anterior deprogramer with bite registeration material for data aquesition and usual construction method using clear acrylic. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Digitally manufactured occlusal splint. | Device | digitally manfactured occlusal splint using intra oral scanner and jaw traccking device for data acqusition and 3d printing for manfacturing of the device |
| Measure | Description | Time Frame |
|---|---|---|
| occlusal force distribution | the distribution of force between right and left side will be assessed using occlusosense device | the outcome will be measured immediately after the device insertion |
| Measure | Description | Time Frame |
|---|---|---|
| cost effectiveness | the cost effectiveness will be measured using the following equation (CE ratio = C/E) | the outcome will be measured immediately after the device insertion |
Not provided
Inclusion Criteria:• Age range from 20 to 60 years old.
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| fatma H saleh, master of prosthodontics | Contact | +201011164489 | fatma.hussein@dentistry.cu.edu.eg |
Not provided
Not provided
iam not going to share the IPD for privacy and security of the informations
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002012 | Bruxism |
| ID | Term |
|---|---|
| D014076 | Tooth Diseases |
| D009057 | Stomatognathic Diseases |
| D006184 | Habits |
| D001519 | Behavior |
Not provided
Not provided
Not provided
Not provided
Not provided
the statistatian
| conventionally manufactured occlusal splint | Device | the occlusal device will be manufactured conventionally using impression and and anterior deprogramer with bite registeration material for data aquesition and usual construction method using clear acrylic. |
|