The purpose of this study is to evaluate the repeatability of magnetic resonance imaging (MRI) in patients with isocitrate dehydrogenase 1 (IDH1) mutant (mIDH1) low-grade diffuse glioma [World Health Organization (WHO) grade 2] who are receiving off-label ivosidenib.
40 adult patients with histologically low-grade mIDH1 glioma (WHO grade 2) who are being seen at Duke Preston Robert Tisch Brain Tumor Center (PRTBTC) for treatment or evaluations, will be included in this protocol. Patients included in this protocol must currently be receiving off-label ivosidenib per recommendation of their treating physician and must be scheduled to receive a routine contrast-enhanced brain Magnetic Resonance Imaging (MRI) scan as part of their clinical care. The images from the routine MRI scan will be obtained as part of the patient's clinical care and will only be used in this research study if the patient agrees to be on-study by signing the informed consent form (ICF).
Subjects will undergo a routine Brain Tumor Imaging Protocol MRI scan with additional imaging sequences, in order to create a database of short interval "coffee break" repeat MRI sets. Subjects will begin their MRI by having T1-pre, T2w, and volumetric 3D Fluid Attenuated Inversion Recovery (FLAIR) images. The subject will be brought out of the magnet, sat up and then have the standard Brain Tumor Imaging Protocol MRI scan performed.
Subjects will remain on this study for the one day during which they are scheduled to receive their MRI scan
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Magnetic Resonance Imaging (MRI) Scan | Experimental | Subjects will begin the MRI with T1-pre, T2w, and volumetric 3D Fluid Attenuated Inversion Recovery (FLAIR) images being obtained. The subject will be brought out of the MRI magnet and moved into a seated position and will then have a standard Brain Tumor Imaging Protocol MRI scan. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| MRI Scan | Diagnostic Test | Subjects will begin the MRI with T1-pre, T2w, and volumetric 3D FLAIR images being obtained. The subject will be brought out of the MRI magnet and moved into a seated position and will then have a standard Brain Tumor Imaging Protocol MRI scan. |
| Measure | Description | Time Frame |
|---|---|---|
| Repeatability | Bland-Altman repeatability will be measured to create a repeat dataset test bed for the evaluation of current and new software for the ability to consistently measure change in the volume of tumor-related T2/Fluid Attenuated Inversion Recovery (FLAIR) abnormality. | 1 year |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
1. Inability to have MRIs
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Katherine Peters, M.D.; Ph.D | Duke University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Duke University Medical Center | Durham | North Carolina | 27710 | United States |
Not provided
| Label | URL |
|---|---|
| The Preston Robert Tisch Brain Tumor Center | View source |
| Duke Health Clinical Trials | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D008279 | Magnetic Resonance Imaging |
| ID | Term |
|---|---|
| D014054 | Tomography |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided