Intra-individual comparison of the PureSee EDOF IOL with the Acunex Vario EDOF IOL set for emmetropia.
Spectacle-independence is a growing goal in modern cataract surgery. The procedure has evolved from a simple restoration of vision to a presbyopia correction approach. Although bilateral monofocal IOL implantation with the goal of emmetropia results in high patient satisfaction for distance vision, spectacle-dependence for reading and intermediate vision tasks is the usual outcome.
Enhanced Depth of Focus (EDOF) lenses have been on the market for some time to minimize this spectacle-dependency in intermediate tasks (computer work, dashboard, etc.). These IOLs have an extended distance focal range that extends into the intermediate distance, providing high quality vision over a continuous focal range, rather than single foci with blurring in between. The risk to the patient is comparable to that of all other monofocal systems, which generally have high patient satisfaction. The benefit of this study should be continuous sharp binocular vision at distance, intermediate (66 cm) and even near (40 cm). Another expected effect is the reduction of dysphotopic phenomena compared to other EDOF lenses.
The aim of this study is to compare the visual performance of two refractive EDOF lenses, namely the Acunex Vario with the Puresee IOL, in an intraindividual comparative study design. In order to achieve a satisfactory result, we planned to include 40 patients scheduled for cataract surgery in the study.
The examinations will all take place one week before, 1 week and 4-6 months after the operation. These include a visual acuity check at the three distances mentioned, slit lamp examination, pressure control, biometry, pupil width, defocus curve, quality of vision questionnaires, contrast sensitivity, halo&glare, optical coherence tomography, fundus examination, aberrometry and keratometry.
The main parameter to be examined is the distance-corrected visual acuity for the intermediate distance (66 cm) between the two IOLs at the follow-up examination after 4-6 months.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Acunex Vario AN6V | Experimental | Patients will receive the Acunex IOL during cataract surgery |
|
| PureSee | Experimental | Patients will receive the PureSee IOL during cataract surgery |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Low-Add EDOF IOL | Device | Acunex Vario AN6V |
| |
| EDOF IOL |
| Measure | Description | Time Frame |
|---|---|---|
| Distance corrected visual acuity for intermediate distance | Distance corrected visual acuity for intermediate distance given in logMAR will be measured at 66 cm using ETDRS charts | 6 months |
| Measure | Description | Time Frame |
|---|---|---|
| Uncorrected visual acuity for intermediate distance | Uncorrected visual acuity for intermediate distance given in logMAR will be measured at 66 cm using ETDRS charts | 6 months |
| Uncorrected and distance corrected visual acuity for far distance |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Johannes Zeilinger, MD | Contact | 01 91021 57564 | office@viros.at | |
| Manuel Ruiss, MSc | Contact | 01 91021 57564 | office@viros.at |
| Name | Affiliation | Role |
|---|---|---|
| Oliver Findl, Univ. Prof. Prim. Dr. | Vienna Institute for Research in Ocular Surgery (VIROS) | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna | Recruiting | Vienna | Austria | 1140 | Austria |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
PureSee EDOF IOL |
|
Uncorrected and distance corrected visual acuity for far distance given in logMAR will be measured at 4 m using ETDRS charts
| 6 months |
| Uncorrected and distance corrected visual acuity for near distance | Uncorrected and distance corrected visual acuity for near distance given in logMAR will be measured at 40 cm using ETDRS charts | 6 months |
| Defocus curve assessment | Monocular defocus curves will be assessed in logMAR at 4 m using an ETDRS chart | 6 months |
| Halometry | Potential halos will be assessed using the Aston Halometer App provided on a Tablet at 2 m | 6 months |
| Contrast sensitivity | Contrast sensitivity will be tested using the Optec device | 6 months |
| Subjective rating of dysphotopsia | Dysphotopsia will be subjectively rated by the patients using a questionnaire and a visual analogue scale | 6 months |