The objective of this study was to compare the objective visual outcomes and subjective fuctional vision of four different intraocular lens (IOL) in patients underwent cataracts surgery. This was a retrospective study. Patients with age-related cataract underwent phacoemulsification combined with IOLs implantation. Patients were divided into 4 groups. Uncorrected distant visual acuity(UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA),and the best corrected visual acuity (BCVA) 1 month and 3 months after the surgery were determined. The defocus curve, contrast sensitivity, and customized VF-14-oriented Visual Function Index questionnaire were performed 3 months postoperatively. Kruskal-Wallis test and generalized estimating equation(GEE) were used to analyze and compare the difference between objective visual outcomes and subjective visual quality among different groups.
The objective of this study was to compare the objective visual outcomes and subjective fuctional vision of four different intraocular lens (IOL) in patients underwent cataracts surgery. This was a retrospective study. Patients with age-related cataract underwent phacoemulsification combined with IOLs implantation. Patients were divided into group A (TECNIS PCB00 IOL), Group B (HumanOptics Diff-Aay IOL), Group C (TECNIS Symfony ZXR00 IOL) and group D (ZEISS AT LISA tri 839MP IOL). Uncorrected distant visual acuity(UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA),and the best corrected visual acuity (BCVA) 1 month and 3 months after the surgery were determined. The defocus curve, contrast sensitivity, and customized VF-14-oriented Visual Function Index questionnaire were performed 3 months postoperatively. Kruskal-Wallis test and generalized estimating equation(GEE) were used to analyze and compare the difference between objective visual outcomes and subjective visual quality among different groups.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| TECNIS PCB00 IOL (A) | The patients in this groups underwent cataract surgery with TECNIS PCB00 IOL |
| |
| HumanOptics Diff-Aay IOL (B) | The patients in this groups underwent cataract surgery with HumanOptics Diff-Aay IOL |
| |
| TECNIS Symfony ZXR00 IOL (C) | The patients in this groups underwent cataract surgery with TECNIS Symfony ZXR00 IOL |
| |
| ZEISS AT LISA tri 839MP IOL (D) | The patients in this groups underwent cataract surgery with ZEISS AT LISA tri 839MP IOL |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| TECNIS PCB00 intraocular lens | Device | In this study, we select TECNIS PCB00 IOL for inserting in the eyes during the cataract surgery |
|
| Measure | Description | Time Frame |
|---|---|---|
| Postoperative visual acuity | The uncorrected distant visual acuity(UDVA), the best corrected distant visual acuity (BCVA) (5 m), the uncorrected intermediate visual acuity(UIVA) (80 cm) and the uncorrected near visual acuity(UIVA) (40 cm) were chosen as the index to evaluate the VA. The UDVA and BCVA were examined by logarithmic visual acuity chart. The UIVA and UIVA were examined by using a near eye chart.They were all measured 1 month and 3 months after the surgery. | 3 months |
| Postoperative contrast sensitivity | The contrast sensitivity was used to conduct the assessment by CSV-1000E (VectorVision, USA) under photopic (85 cd/m2) condition at a 2.5m distance. The logarithmic values for 3, 6, 12, and 18 cycles/degree (c/d) were analyzed 3 months postoperatively. | 3 months |
| Postoperative defocus curve | Defocus curve was used to evaluate the visual quality of functional intraocular lens after surgery. The insertion range was -4.0 D ~ + 2.0 D, increasing by 0.5 D. The best corrected distant visual acuity was recorded at each diopter 3 months postoperatively. | 3 months |
| Postoperative eye-related quality of life | Based on the American Questionnaire on Visual Function Index-14 (VF-14), the Chinese-oriented version(VF-12-CN) was used to investigate the postoperative near-vision, visual satisfaction, ocular discomfort, visual disturbance, and subjective feelings of far-vision, middle-vision and near-vision. Each question was divided into 4 levels and the scores ranked from 0 to 3 points. Considering the visual interference such as glare and halo, the evaluation of glare and halo visual interference phenomenon was also added. | 3 months after surgery |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Cataract ultrasonic emulsification aspiration with one-stage implantation of 4 types of IOLs at the Shanghai Tenth People's Hospital from October 2021 to June 2023
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Yiwen Hu | Shanghai 10th People's Hospital | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Shanghai 10th People's Hospital | Shanghai | Shanghai Municipality | 200000 | China |
Not provided
| ID | Term |
|---|---|
| D002386 | Cataract |
| ID | Term |
|---|---|
| D007905 | Lens Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| HumanOptics Diff-Aay intraocular lens | Device | In this study, we select HumanOptics Diff-Aay IOL for inserting in the eyes during the cataract surgery |
|
|
| TECNIS Symfony ZXR00 intraocular len | Device | In this study, we select TECNIS Symfony ZXR00 IOL for inserting in the eyes during the cataract surgery |
|
|
| ZEISS AT LISA tri 839MP intraocular len | Device | In this study, we select ZEISS AT LISA tri 839MP IOL for inserting in the eyes during the cataract surgery |
|
|