Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| University of Birmingham | OTHER |
Not provided
Not provided
Not provided
Not provided
This is a retrospective cohort study that evaluates the survival (Outcome 1) of dental implant systems (external connection (Cohort 1) and internal connection (Cohort 2) and the effectiveness of maintaining crestal bone levels (Outcome 2), placed within United Kingdom Armed Forces personnel. The secondary objectives include: assessment of block bone grafting on outcome, assessment of restoration (bridge vs crown on outcome) and assessment of placement technique (immediate, early, delayed placement). Inclusion criteria: all military patients that received dental implants since 2014-2024. Exclusion criteria: military patients that have not received radiographic review or follow-up of the dental implant or who have left service or have a follow-up that is less than 12-months post placement of the dental implant..
Dental care to the United Kingdom Armed Forces (UKAF) is provided by Defence Primary Healthcare (DPHC) Dental, which incorporates a Managed Clinical Network (MCN) to co-ordinate and treat complex restorative cases referred by general dental practitioners (GDPs), with a central hub at the DCRD. The DCRD routinely employs dental implants within patients' rehabilitative treatment pathways.
Nobel Biocare are the sole provider of dental implants to DPHC with three-systems (Nobel Speedy Groovy, Nobel Active and Nobel Parallel) routinely employed. Of the three systems, Nobel Speedy Groovy have been in use for over 20-years, employing an external hexagon prosthet-ic connection (EH). With EH, the microbiological junction lies at the vertical junction of the abutment and implant (Platform-Matched (P-M)). Subsequently, a 1mm zone of inflammation occurs around this junction with associated crestal bone loss. The establishment of crestal bone levels at the first thread of the implant was within the parameters of implant success. In contrast, Nobel Active and Parallel systems employ an internal conical connection (CC) that facilitates a platform-switching (P-S) approach to restoration of the implant. The platform switching concept aims to move the microbiological junction to the horizontal coronal surface of the implant, away from the implant/ alveolar junction, with the aim of preserving vertical crestal bone to the full height of the implant. This study aims to evaluate whether platform-switching influences dental implant survival (primary outcome) and radiographic bone levels (secondary outcome).
The study aims to account for the following factors on the outcome measures: dental implant pathway protocol (immediately-, early-, delayed- or late-placement protocols post extraction), bone grafting (to facilitate implant provision) either undertaken either prior to- or during- implant placement (block grafting, sinus floor elevation, augmentation at time of placement) and restoration type (crown, bridge, over-denture support).
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Platform-matched | UK Armed Forces patients who had platform-switched implants (Nobel Brånemark or NobelSpeedy Groovy) placed at DCRD between the period of 01 Jan 2017 and 31 Dec 2023. |
| |
| Platform-switched | UK Armed Forces patients who had platform-switched implants (NobelParallel or NobelActive) placed at DCRD between the period of 01 Jan 2017 and 31 Dec 2023. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Platform-switched implant placement | Procedure | NobelParallel or NobelActive implants placed |
|
| Measure | Description | Time Frame |
|---|---|---|
| Dental Implant Survival (presence of implant at point of review) | Null hypothesis: No difference in dental implant survival between the 2 cohorts (Platform-Matched vs Platform-Switched dental implant/ abutment interfaces). This is a binary outcome of either implant still present or implant absent at time of review. | Minimum time frame for inclusion is 12 months |
| Measure | Description | Time Frame |
|---|---|---|
| Dental Implant Crestal Bone Levels | Null hypothesis: There is no difference in the crestal bone levels between the 2 cohorts (Platform-Matched vs Platform-Switched dental implant/ abutment interfaces). This outcome is measured radiographically using a software programme to determine changes in bone levels. Outcome is measured in mm. | Minimum time frame for inclusion is 12 months |
Not provided
Inclusion Criteria:
• Military patients who had dental implants placed at DCRD between the period of 01 Jan 2017 and 31 Dec 2023.
Exclusion Criteria:
• Implants placed outside of DPHC.
Not provided
Not provided
Not provided
Not provided
UK Armed Forces
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Defence Centre of Rehabiliative Dentistry | Aldershot | Surrey | GU11 2LG | United Kingdom |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Platform-matched implant placement | Procedure | Nobel Brånemark, NobelSpeedy Groovy implants placed |
|
| ID | Term |
|---|---|
| D016388 | Tooth Loss |
| ID | Term |
|---|---|
| D010510 | Periodontal Diseases |
| D009059 | Mouth Diseases |
| D009057 | Stomatognathic Diseases |
| D014076 | Tooth Diseases |
Not provided
Not provided