Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The ultrasound of the optic nerve sheath diameter (ONSD) is a non-invasive tool used in the detection of intracranial hypertension and other neurological conditions. The aim of this research is to evaluate the correlation between the ultrasound measurement of the optic nerve sheath diameter and the side of neurological focus in the physical examination of adult patients evaluated in emergency departments.
II. Hypothesis The ultrasound measurement of the optic nerve sheath diameter correlates with the side of neurological focus in the physical examination of adult patients evaluated in emergency departments.
III. Objectives Estimate the correlation between the ultrasound measurement of the optic nerve sheath diameter and the side of neurological focus in the physical examination of adult patients evaluated in emergency departments.
Determine the sensitivity and specificity of the ultrasound measurement of the optic nerve sheath diameter for predicting the side of neurological focus.
IV. Methodology
Study design:
A observational study will be conducted in a secondary care hospital.
Population and sample:
Adult patients (≥18 years) presenting to the emergency department with neurological symptoms, such as headache, altered level of consciousness, motor or sensory deficit, among others, will be included. Patients with contraindications for ocular ultrasound or with a history of previous ocular surgery will be excluded.
Procedures:
Data analysis:
The correlation between the ultrasound measurement of the optic nerve sheath diameter and the side of neurological focus will be calculated using Pearson's or Spearman's correlation coefficient, depending on the distribution of the data. Additionally, sensitivity, specificity, positive and negative predictive values, and 95% confidence intervals will be calculated to determine the diagnostic utility of the ultrasound measurement of the optic nerve sheath diameter in identifying the side of neurological focus.
V. Ethical considerations The ethical guidelines established by the Declaration of Helsinki will be followed, and the privacy and confidentiality of patients will be protected. The protocol will be approved by the hospital's Research Ethics Committee before its implementation.
Not provided
Not provided
Not provided
Not provided
Not provided
| Measure | Description | Time Frame |
|---|---|---|
| Correlation between optic nerve sheath and side of clinical neurological focalization | Estimate the correlation between the ultrasound measurement of the optic nerve sheath diameter and the side of neurological focus in the physical examination of adult patients evaluated in emergency departments. | In the first 4 hours of arrival to Emergency Department |
| Measure | Description | Time Frame |
|---|---|---|
| sensitivity and specificity of the ultrasound measurement of the optic nerve sheath diameter for predicting the side of neurological focus. | Determine the sensitivity and specificity of the ultrasound measurement of the optic nerve sheath diameter for predicting the side of neurological focus. | In the first 4 hours of arrival to Emergency Department |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
The study aims to include a diverse adult population, encompassing various ages, genders, and ethnic backgrounds, reflective of the general demographic seen in emergency departments with suspected ischemic stroke. By doing so, the study seeks to enhance the generalizability of its findings across different subgroups within the adult population.
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Clinica Mexico | Piedras Negras | Coahuila | 26020 | Mexico |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 36836888 | Background | Lau T, Ahn JS, Manji R, Kim DJ. A Narrative Review of Point of Care Ultrasound Assessment of the Optic Nerve in Emergency Medicine. Life (Basel). 2023 Feb 15;13(2):531. doi: 10.3390/life13020531. | |
| 38099170 | Background | Nathani A, Ghamande SA, Kambhampati S, Anderson B, Lohse M, White HD. The Use of POCUS-Obtained Optic Nerve Sheath Diameter in Intracerebral Hemorrhage. POCUS J. 2023 Nov 27;8(2):170-174. doi: 10.24908/pocus.v8i2.16563. eCollection 2023. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D000083242 | Ischemic Stroke |
| D020521 | Stroke |
| D004630 | Emergencies |
| ID | Term |
|---|---|
| D002561 | Cerebrovascular Disorders |
| D001927 | Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
Not provided
Not provided
Not provided
Not provided
Not provided
| 21769456 | Background | Rajajee V, Vanaman M, Fletcher JJ, Jacobs TL. Optic nerve ultrasound for the detection of raised intracranial pressure. Neurocrit Care. 2011 Dec;15(3):506-15. doi: 10.1007/s12028-011-9606-8. |
| 21121998 | Background | Bauerle J, Lochner P, Kaps M, Nedelmann M. Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults. J Neuroimaging. 2012 Jan;22(1):42-5. doi: 10.1111/j.1552-6569.2010.00546.x. Epub 2010 Dec 1. |
| 18275454 | Background | Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008 Feb;15(2):201-4. doi: 10.1111/j.1553-2712.2007.00031.x. |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
| D020969 | Disease Attributes |
| D010335 | Pathologic Processes |
| D013568 | Pathological Conditions, Signs and Symptoms |