Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Previous studies have investigated the impact of tDCS on systemic glucose, neglecting to explore its effects on diabetic factors and its safety. Some studies used small sample size, limiting the ability to identify significant impacts or generalized findings to large population.
The proposed study suggests addressing these gaps by employing a large sample size, comprehensive outcome measurements, assessing tDCS impact on diabetes mellitus (DM) risk variables, and integrating ethical considerations into the research design and implementation. The study aims to fill existing gaps in knowledge about tDCS effects on blood glucose regulation and diabetic risk factors by conducting more robust research methodologies The effects of tDCS on addictive behavior and cerebral glucose metabolism in problematic online gamers were examined in a single-blinded RCT. Over a 4-weekperiod, participants received 12 sessions of either active or sham tDCS to the dorsolateral prefrontal cortex. In the active group, glucose metabolism was enhanced in certain brain regions, showing decreased addiction severity in both groups. As a result of these findings, it appears that prefrontal tDCS is capable of controlling gaming behaviors and enhancing cerebral glucose metabolism
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| tDCS Group | Experimental |
| |
| Sham Group | Sham Comparator |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| tDCS | Device | The DCS electrode sheaths of 7x5 cm will be soaked with standard saline solution(NaCl 9%) and fixed by elastic bands. tDCS will deliver 20 min of anodal stimulation (1-2mA, fade in/out 8 sec) |
| Measure | Description | Time Frame |
|---|---|---|
| RBS | Two hours after meal, peripheral venous blood samples are collected to check random blood glucose levels. The morning random glucose level had a linear relationship with glycated haemoglobin levels taken simultaneously. A blood glucose level of 7 mmol/l had 92.7% sensitivity for good control (HbA1c < or = 7.8%) on a blood sample which was taken simultaneouslyand59.8% specific for the same | 2-4 hours |
| 6 Minute walk test | The 6-minute walk test (6MWT) is widely employed in clinical settings due to its ease of administration, good tolerance, and safety. It assesses functional exercise capacity by measuring the distance an individual walks in 6 minutes. Moreover, it serves as a valuable predictor of morbidity and mortality across various cardiopulmonary conditions, demonstrating excellent reliability (ICC = 0.9) and validity in healthy adults. | baseline |
| Measure | Description | Time Frame |
|---|---|---|
| International physical activity questionnaire (IPAQ-SF) | This cost-effective measure will assess participants' physical activity intensity and sitting time to estimate total physical activity in MET-min/week. It records activity levels across four categories: vigorous-intensity (e.g., aerobics), moderate-intensity (e.g., leisure cycling), walking, and sitting. The International Physical Activity Questionnaire Short Form(IPAQ-SF)demonstrates good test-retest reliability (ICC > 0.65) and satisfactory criterionvalidity in healthy adults |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Sumaiyah Obaid, MSPT | Riphah International University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Pakistan Railway General Hospital | Rawalpindi | Punjab Province | Pakistan |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 31598826 | Background | Kraus C, Hahn A, Sigurdardottir H, Spurny B, Wadsak W, Mitterhauser M, Hacker M, Kasper S, Lanzenberger R. Brain glucose uptake during transcranial direct current stimulation measured with functional [18F]FDG-PET. Brain Imaging Behav. 2020 Apr;14(2):477-484. doi: 10.1007/s11682-019-00195-4. | |
| 28392373 | Background |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D044882 | Glucose Metabolism Disorders |
| ID | Term |
|---|---|
| D008659 | Metabolic Diseases |
| D009750 | Nutritional and Metabolic Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D065908 | Transcranial Direct Current Stimulation |
| ID | Term |
|---|---|
| D004599 | Electric Stimulation Therapy |
| D013812 | Therapeutics |
| D003295 | Convulsive Therapy |
| D013000 | Psychiatric Somatic Therapies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Sham tDCS | Other | sham-tDCS will be applied for 30 s to make it difficult for the individual to distinguish the placebo from a real tDCS application |
|
| baseline |
| Rapid Assessment of Physical Activity (RAPA) | RAPA is a self-administered questionnaire comprising 9 items with yes or no responses, determining the level of physical activity. The first 7 items assess aerobic activity (RAPA 1), while the last 2 items focus on strength and flexibility(RAPA 2) and are not included in the total score. Test-retest reliability for RAPA in healthy adults is high, with a calculated value of 0.996 (95%CI0.992-0.998), indicating very good reliability | baseline |
| Finish Diabetes Risk Score | The Finnish Diabetes Risk Score (FINDRISC) questionnaire is a validated tool for predicting type 2 diabetes risk. It estimates the probability of developing diabetes within the next 10 years. FINDRISC demonstrates excellent reliability, with an Intra class Correlation Coefficient (ICC) of 0.94. | baseline |
| GAD-7 | The 7-item Generalized Anxiety Disorder Scale (GAD-7) is a self report tool for assessing symptoms of GAD, including excessive and uncontrollable anxiety and worry lasting at least 6 months. The scale demonstrates excellent reliability in young adults, with a cronbach'sαcoefficient of 0.895, surpassing the recommended threshold of 0.80 | baseline |
| Waist and Hip Ratio | Waist and hip circumference measurements serve as cost-effective, non-invasive indicators of body fat distribution and disease risk. High Intra class Correlations (ICC) between self and technician measurements are observed, with values of 0.97 for waist and 0.96 for hip circumference. Additionally, self-measurements at home exhibit high test-retest reliability, with ICC values of at least 0.87 when compared to lab measurements | baseline |
| BMI | Body Mass Index (BMI) is a measure utilizing height and weight to assess obesity, with values ranging from <18.5 to >30. BMI demonstrates high reliability, with an Intra class Correlation Coefficient (ICC) of 0.96 | baseline |
| Kistenmacher A, Manneck S, Wardzinski EK, Martens JC, Gohla G, Melchert UH, Jauch-Chara K, Oltmanns KM. Persistent blood glucose reduction upon repeated transcranial electric stimulation in men. Brain Stimul. 2017 Jul-Aug;10(4):780-786. doi: 10.1016/j.brs.2017.03.011. Epub 2017 Mar 25. |
| 21703596 | Background | Binkofski F, Loebig M, Jauch-Chara K, Bergmann S, Melchert UH, Scholand-Engler HG, Schweiger U, Pellerin L, Oltmanns KM. Brain energy consumption induced by electrical stimulation promotes systemic glucose uptake. Biol Psychiatry. 2011 Oct 1;70(7):690-5. doi: 10.1016/j.biopsych.2011.05.009. Epub 2011 Jun 24. |
| D004191 | Behavioral Disciplines and Activities |
| D004597 | Electroshock |
| D011580 | Psychological Techniques |