Not provided
The aim of study to analyze morphometry of sub axial cervical spine pedicle in an Egyptian population based on computed tomography (CT) and thus asses the safety and feasibility of cervical pedicle screw in the sub axial cervical spine
Cervical pedicle screw (CPS) fixation is found to be superior compared with lateral mass screws because it provides more axial, bending and torsional stability and has a low risk of loosening with cyclical loading . Despite biomechanical superiority, CPS fixation is not universally accepted among surgeon s because their accuracy and safety remain technically challenging because of the close proximity of vital structures as spinal cord and vertebral artery and inherent variability in pedicle at each level. In addition. limited space is available for screw placement because of complex of cervical spine vertebrae. Therefore, the risk of complication due to screw violation of the adjacent vascular and neural structures is expected to be high when performing the operation without a clear understanding of morphometric characteristics of the pedicle .Morphometry of the cervical pedicles was studied before using cadavers but comparative computed tomography (CT) data from the age matched population shown significant differences. Recent advances in CT have made anatomic measurements more accurate. The present study was undertaken to determine the 3-dimensional pedicle geometry by calculating variables like pedicle length (PL). Pedicle height (PH). Pedicle width (PW), Pedicle axis length (PAL), Pedicle transverse angulation (PTA), Pedicle sagittal angulation (PSA), Superior pedicle distance (SPD), and lateral pedicle distance (LPD). Fortunately, computed tomography (CT) scanning become a routine preoperative examination in spinal surgery patients.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Cervical pedicle screw | Device | cervical pedicle screw |
| Measure | Description | Time Frame |
|---|---|---|
| Assessment of feasibility of sub axial cervical spine pedicle | Morphometric Analysis of sub axial cervical spine pedicle in Egyptian population | Baseline |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Sample size was calculated using Epi- Info7. According to results of previous study (put ref.) , the pullout strength failed by fracture of pedicle screw in 40% of patients undergoing cervical spine CT. Based on this percentage, confidence limits of 7% and a confidence level of 80%, the sample needed for the study was estimated to be about 80 patients.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Michael Mikhaeel, Resident | Contact | 01283635331 | michaelatef936@gmail.com | |
| Mahmoud Fouad, professor | Contact | 01142227270 | mfibrahim@aun.edu.eg |
Not provided
Not provided
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30276069 | Background | Farooque K, Yadav R, Chowdhury B, Gamanagatti S, Kumar A, Meena PK. Computerized Tomography-Based Morphometric Analysis of Subaxial Cervical Spine Pedicle in Asymptomatic Indian Population. Int J Spine Surg. 2018 Aug 3;12(2):112-120. doi: 10.14444/5017. eCollection 2018 Apr. |