Central venous (CVC) is essential in modern healthcare but unfortunately associated with complications, including thrombosis. In a recently published study, it was showed that 12 out of 12 deceased patients had subclinical CVK-related thrombosis (Rockholt et al.). To shed light on this problem, the current studies were designed. In sub-study 1, deceased patients with CVC who are referred for clinical autopsy are included. Before the autopsy, the deceased will be examined with a photon-counting computed tomography (CT) scan and the results will be compared.
In sub-study 2, living patients with CVC who are referred for various CT scans without contrast, are included. After informed consent, the patient will be examined with the photon-counting CT, whose reliability has been validated in Part 1 and the incidence of subclinical CVC-related thrombosis will be reported.
Purpose and specific objective The aim of the current project (PHOTO CAT) is to evaluate the prevalence of subclinical thromboses related to central venous catheters (CVCs) using a novel high-resolution photon-counting computed tomography (CT) scan and to evaluate the performance of the photon-counting CT compared to clinical autopsy.
Scientific questions
Background CVCs are essential in modern healthcare and have a wide range of applications. They enable direct access to the central bloodstream and are used, among other things, to administer medicines, nutrition and to monitor blood circulation. Unfortunately, they are associated with a variety of complications, including thrombosis. Studies report thrombosis incidences between 5 - 30% in living patients. When the CVC is introduced into the blood vessel, a number of physiological defense systems are initiated. Inflammation and clotting are activated, leading to the formation of a fibrin stocking around the catheter. This can then develop into a catheter-related thrombosis, which in turn can have serious consequences for the patient, such as pulmonary embolism or infection.
Photon-counting DT is the new generation of DT. What distinguishes this from the traditional one is that the radiation through the body is detected with a new type of detector that measures each X-ray, which provides significantly greater precision and resolution for a given radiation dose compared to traditional CT. This is particularly valuable in imaging diagnostics that rely on detailed morphology such as high-resolution CT of lungs. In order to achieve its full potential with as little radiation dose and contrast volume as possible with preserved image resolution, the design of protocols for the photon-counting CT needs to be optimized.
Autopsy studies on CVC-related thrombosis and vascular changes are few. In a case series from 1994, changes in the vessel wall were examined macroscopically and biofilms were assessed with electron microscopy. The presence of fibrin stocking on the surface of all CVCs (n = 72), and wall-mounted thrombosis was reported in 38% of cases. In another autopsy study, Forauer et al. demonstrated severe CVC-related vascular changes that included intima damage with infiltration of media by inflammatory cells and varying degrees of adherent thrombus. Wichmann et al. published data showing a 38% prevalence of macroscopic catheter-related thrombosis in 61 human autopsies. In a recently published autopsy study, we showed that 12 out of 12 cases had CVC-related mural thrombosis at autopsy, with most being located in the distal part of the CVC (Rockholt et al.).
There are also a number of clinical studies that have investigated how common CVC-related thrombosis is using ultrasound. In a well-designed prospective study, 16.9% of ICU patients had subclinical CVK-related thrombosis. The problem with the ultrasound method is that the distal part of the CVC is difficult to visualize with ultrasound, which means that the thrombosis incidence risks being underestimated.
Material and method In an attempt to investigate how common subclinical CVK-related thrombosis, the current studies, include photon-counting CT, were designed.
In substudy 1, photon counting CT is used to examine deceased intensive care patients referred for autopsy on clinical indication, with CVC in-situ. The CT will be focused on the vein with the CVC but a full body examination will also be done . Both examination results will be compared with the clinical autopsy conducted after the examinations. This first part of PHOTO CAT includes Scientific questions 1-3.
In sub-study 2, living patients with CVC who are referred for CT scan without contrast, will be eligable for inclusion. After consent, the study will be carried out with photon counting CT in two phases. First, the examination for which the patient was referred, will be performed. In the second phase, a targeted examination is performed for research purposes of the vein with the CVC. Within 12 hours before or after the CT scan, it is planned to perform an ultrasound scan of the vein where the CVC is located. The aim is to evaluate the performance of ultrasound examination in detecting CVC-related thrombosis, compared to photon-counting CT. Sub-study 2 of PHOTO CAT includes Questions 4-6.
Analysis of data and statistics No one has previously reported photon-counting CT to detect CVC-related thromboses. Therefore, the current exploratory study is planned. The results may form the basis for sample size calculation in future studies.
Significance In patients with CVC, subclinical CVC-related thromboses are very common. These seem to cause surprisingly few clinical problems. However, it should be noted that several of the actual symptoms that CVC-related thrombosis can cause may go unnoticed or misinterpreted as symptoms of the disease that caused the patient's to need of a CVC. It is important to know the true incidence of subclinical CVC-related thrombosis in order to evaluate the risk-benefit of central venous access compared to alternatives (peripheral venous access, midline, PICCLINE, porth-a-cath), and in the development of new less thrombogenic CVC materials.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Diseased patients with an indwelling central venous catheter | Sub study 1, Diseased patients with an indwelling central venous catheter |
| |
| Living patients with an indwelling central venous catheter | Living patients with an indwelling central venous catheter who are referred to a CT-scan without intravenous contrast |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Diseased patients with an indwelling central venous catheter who is referred to autopsy | Diagnostic Test | Photon counting CT is performed and the results are compared to the results of the autopsy |
| Measure | Description | Time Frame |
|---|---|---|
| The incidence of venous thrombosis related to a central venous catheter in diseased patients | Venous thrombosis related to a central venous catheter detected at autopsy | At autopsy |
| The performance of the photon counting CT on diseased patients | The performance of the photon counting CT will be evaluated by comparing the findings from the CT with the findings from the autopsy | After death. The CT scan and the autopsy will be performed within 1 week after death |
| The incidence of venous thrombosis related to a central venous catheter in living patients | The incidence of venous thrombosis related to a central venous catheter in living patients detected with a photon counting CT | At CT scan |
| The performance of ultrasound compared to the photon counting CT | The performance of ultrasound compared to the photon counting CT in detecting enous thrombosis related to central venous catheters | Ultrasound will be performed ±24 hours from the CT |
Not provided
Not provided
Substudy 1
Inclusion Criteria:
Exclusion Criteria:
Substudy 2 Inclusion Criteria
Exclusion Criteria
- GFR <15 mL/min/1.73 m2
Not provided
Not provided
Not provided
Substudy 1: Diseased patients with an indwelling central venous catheter and a clinical indication for autopsy
Substudy 2: Living patients with an indwelling central venous catheter who are referred to a CT scan without iv contrast
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Thomas Kander, PhD | Contact | +4646171163 | thomas.kander@med.lu.se | |
| Emilia Ängeby Eriksson, MD | Contact | +4646175155 | emilia.angeby@med.lu.se |
| Name | Affiliation | Role |
|---|---|---|
| Thomas Kander | Lund University | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Intensive and Perioperative Care. Skåne University Hospital. Lund | Recruiting | Lund | Skåne County | 22185 | Sweden |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 14514808 | Background | Forauer AR, Theoharis C. Histologic changes in the human vein wall adjacent to indwelling central venous catheters. J Vasc Interv Radiol. 2003 Sep;14(9 Pt 1):1163-8. doi: 10.1097/01.rvi.0000086531.86489.4c. | |
| 29793590 | Background | Wichmann D, Heinemann A, Zahler S, Vogel H, Hopker W, Puschel K, Kluge S. Prospective study of device-related complications in intensive care unit detected by virtual autopsy. Br J Anaesth. 2018 Jun;120(6):1229-1236. doi: 10.1016/j.bja.2018.02.031. Epub 2018 Apr 4. |
Not provided
Not provided
Upon reasonable request, de-identified individual participant data from this clinical trial will be shared to facilitate scientific collaboration.
After the publication of the study up to 3 years after the publication of the study
Researchers may submit requests through the specified channel, detailing the purpose and proposed analyses. Approved applicants will sign a data access agreement, ensuring responsible and transparent use of the data.
Not provided
Not provided
Not provided
Not provided
Not provided
| Living patients with an indwelling central venous catheter referred to a CT scan without iv contrast | Radiation | Patients will be investigated using a photon counting CT. Prior to the investigation patients will be investigated with ultrasound. The results from the two modalities will be compared |
|
| 38166620 | Background | Rockholt MM, Naddi L, Badri AM, Englund E, Kander T. Macro- and microscopic changes in veins with short-term central venous catheters: an observational autopsy study. BMC Anesthesiol. 2024 Jan 2;24(1):5. doi: 10.1186/s12871-023-02380-x. |
| ID | Term |
|---|---|
| D056824 | Upper Extremity Deep Vein Thrombosis |
| D013927 | Thrombosis |
| ID | Term |
|---|---|
| D020246 | Venous Thrombosis |
| D016769 | Embolism and Thrombosis |
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D003287 | Contrast Media |
| ID | Term |
|---|---|
| D064907 | Diagnostic Uses of Chemicals |
| D020228 | Pharmacologic Actions |
| D020164 | Chemical Actions and Uses |
| D020313 | Specialty Uses of Chemicals |
Not provided
Not provided