Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Technological advances have influenced the approach to implant treatment. One of the fields presently experiencing rapid development is static computer-assisted guided surgery (sCAIS), which allows transfer of the virtual implant planning to the mouth of the patient, based on the use of a surgical guide. In sCAIS there is a deviation between the virtually planned implant position and the actual position of the implant placed during surgery. A recent review analyzed only fully guided implants and recorded a mean coronal horizontal deviation (CHD) of 1.12 mm (standard deviation [SD] = 0.08), a mean apical horizontal deviation (AHD) of 1.41 mm (SD = 0.1), a mean vertical deviation (VD) of 0.12 mm (SD = 0.23), and a mean angular deviation (AD) of 3.58º (SD = 0.2).
The aim of the present study was to compare the accuracy of CAD-CAM and conventional guides in candidates for distal free-end implant treatment, and to analyze the effects of possible confounding factors inherent to the patient or the surgical technique employed.A prospective, controlled and blinded quasi-experimental study was carried out involving 27 patients with 76 implants distributed into two groups according to the surgical guide manufacturing approach used: conventional (control group [CG]) or CAD-CAM (test group [TG]). The implants were planned virtually with the planning software, and the surgical guides were manufactured. Fully guided implant placement was carried out, and the deviations were measured along with other secondary variables as potential confounding factors.
Planning of the implants is made in the ideal prosthetic position based on a previous CAD-CAM (computer aided design - computer aided manufacturing) wax-up. sCAIS facilitates correct prosthetic emergence and therefore contributes to secure optimum esthetic and biological outcomes, affording long-term stability of the soft and hard tissues.
These surgical guides can be manufactured using CAD-CAM or conventional technologies in the laboratory, employing drilling machines or mechanical positioners. In the case of the conventional guide manufactured in the laboratory, the technician creates a radiological guide that is then converted into a surgical guide - the whole process being analogic, except for planning of the implants. At present, and with the development of digital workflows, CAD-CAM procedures are used for both the design and manufacture of the surgical guide, using different processes. This simplifies the workflow, which can reduce the costs of smaller rehabilitations.
Clinical studies on accuracy published in the literature are heterogeneous, with differences in the systems used, the surgical technique, the type of surgical guide support or the type of edentulism involved.These data justify further research in humans, focusing on fully sCAIS, in order to reduce heterogeneity. Furthermore, a review of the literature revealed a lack of clinical publications on the accuracy of CAD-CAM surgical guides compared to conventional guides. Therefore, the aim of the present study was to compare the accuracy of CAD-CAM and conventional guides in candidates for distal free-end implant treatment, and to analyze the effects of possible confounding factors inherent to the patient or the surgical technique employed. Intra- and postoperative complications of the surgical technique were also evaluated, as well as implant success and peri-implant marginal bone loss. Hence, the null hypothesis of the study was the absence of any difference in accuracy between both guides.
A prospective, controlled, examiner- and statistician-blinded, parallel-arm quasi-experimental study was carried out at the University of Valencia (Valencia, Spain). Two groups were established according to the surgical guide design involved: conventional (control group [CG]) or CAD-CAM (test group [TG]).
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Conventional surgical guide | Active Comparator | Implants (Straumann®) placed with an analogic laboratory surgical guide |
|
| Computer aided design - computer aided manufacturing (CAD-CAM) surgical guide | Experimental | Implants (Straumann®) placed with static computer-assisted implant surgery |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Static computer-assisted guided surgery with analogic guide | Procedure | coDiagnostix9® planning software |
|
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy in implants: vertical, apical and coronal horizontal deviations | New CBCT scans were obtained in all patients after implant placement . The coDiagnostix9® application was used to match the pre- and postoperative CBCT images and to compare the axis positions of the planned and placed implants. The vertical, apical and coronal horizontal deviations in millimeters (VD, AHD and CHD), were recorded between the long axis of the virtual planned and actual placed implant. Measured in millimeters | 1 week post-operative |
| Accuracy in implants: angular deviation | New CBCT scans were obtained in all patients after implant placement . The coDiagnostix9® application was used to match the pre- and postoperative CBCT images and to compare the axis positions of the planned and placed implants. The angular deviation in degrees (AD), was recorded between the long axis of the virtual planned and actual placed implant. Measured in degrees. | 1 weel post-operatiive |
| Measure | Description | Time Frame |
|---|---|---|
| Intraoperative complications | Surgical guide fitting, retention, drill access, guide fracture, I | Intra-operative |
| Postoperative complications | Infection, bleeding, edema, neurological alterations, pain, swelling |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| MIGUEL PEÑARROCHA-DIAGO, Phd, DDS | University of Valencia | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| University of Valencia. Faculty of Medecine and Dentistry. CLINICA ODONTOLOGICA | Valencia | Valencia | 46010 | Spain |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 37099571 | Background | Balaguer-Marti JC, Canet-Lopez A, Penarrocha-Diago M, Romeo-Rubio M, Penarrocha-Diago M, Garcia-Mira B. Influence of Splint Support on the Precision of Static Totally Guided Dental Implant Surgery: A Systematic Review and Network Meta-analysis. Int J Oral Maxillofac Implants. 2023 Jan-Feb;38(1):157-168. doi: 10.11607/jomi.9796. | |
| 28632253 |
Not provided
Not provided
Patients' personal data will not be published, however, the results of the scientific study will be published in a scientific dental journal.
Not provided
Not provided
Not provided
Not provided
Not provided
A prospective, controlled, examiner- and statistician-blinded, parallel-arm quasi-experimental study
Not provided
Not provided
single-blind
| Static computer-assisted guided surgery with CAD-CAM surgical guide | Procedure | coDiagnostix9® planning software |
|
|
| One month after implant placement |
| Implant success | Success is defined as no permanent peri implant radiographic translucency, no sign of peri-implant infection with putrid secretion, absence of persistent pain, dysesthesia, and/or foreign-body feeling | One year of implant loading |
| Peri-implant marginal bone loss | Radiographic assessment of the marginal bone loss around the implants | One year of implant loading |
| Bover-Ramos F, Vina-Almunia J, Cervera-Ballester J, Penarrocha-Diago M, Garcia-Mira B. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies. Int J Oral Maxillofac Implants. 2018 January/February;33(1):101-115. doi: 10.11607/jomi.5556. Epub 2017 Jun 20. |
| 36716792 | Background | Chen X, Yang Z, Wang Y, Fu G. Fixation Pins Increase the Accuracy of Implant Surgery in Free-End Models: An In Vitro Study. J Oral Maxillofac Surg. 2023 May;81(5):593-601. doi: 10.1016/j.joms.2022.12.017. Epub 2023 Jan 28. |
| 31381178 | Background | El Kholy K, Lazarin R, Janner SFM, Faerber K, Buser R, Buser D. Influence of surgical guide support and implant site location on accuracy of static Computer-Assisted Implant Surgery. Clin Oral Implants Res. 2019 Nov;30(11):1067-1075. doi: 10.1111/clr.13520. Epub 2019 Aug 20. |
| 30589502 | Background | El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin Implant Dent Relat Res. 2019 Feb;21(1):101-107. doi: 10.1111/cid.12705. Epub 2018 Dec 27. |
| 34218450 | Background | Kessler A, Le V, Folwaczny M. Influence of the tooth position, guided sleeve height, supporting length, manufacturing methods, and resin E-modulus on the in vitro accuracy of surgical implant guides in a free-end situation. Clin Oral Implants Res. 2021 Sep;32(9):1097-1104. doi: 10.1111/clr.13804. Epub 2021 Jul 17. |
| 33359299 | Background | Khorsandi D, Fahimipour A, Abasian P, Saber SS, Seyedi M, Ghanavati S, Ahmad A, De Stephanis AA, Taghavinezhaddilami F, Leonova A, Mohammadinejad R, Shabani M, Mazzolai B, Mattoli V, Tay FR, Makvandi P. 3D and 4D printing in dentistry and maxillofacial surgery: Printing techniques, materials, and applications. Acta Biomater. 2021 Mar 1;122:26-49. doi: 10.1016/j.actbio.2020.12.044. Epub 2020 Dec 26. |
| 36625374 | Background | Le V, Kessler A, Folwaczny M. Influence of DLP and SLA printer technology on the accuracy of surgical guides for implant dentistry in free-end situations. Int J Comput Dent. 2023 Sep 26;26(3):217-226. doi: 10.3290/j.ijcd.b3774115. |
| 28363503 | Background | Matta RE, Bergauer B, Adler W, Wichmann M, Nickenig HJ. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J Craniomaxillofac Surg. 2017 Jun;45(6):804-808. doi: 10.1016/j.jcms.2017.02.015. Epub 2017 Feb 20. |
| 33504723 | Background | Putra RH, Yoda N, Astuti ER, Sasaki K. The accuracy of implant placement with computer-guided surgery in partially edentulous patients and possible influencing factors: A systematic review and meta-analysis. J Prosthodont Res. 2022 Jan 11;66(1):29-39. doi: 10.2186/jpr.JPR_D_20_00184. Epub 2021 Jan 26. |
| 39578942 | Derived | Berta GM, Luigi C, Miguel PD, Carlos BJ. Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides. Clin Oral Implants Res. 2025 Mar;36(3):314-324. doi: 10.1111/clr.14384. Epub 2024 Nov 23. |