Not provided
| ID | Type | Description | Link |
|---|---|---|---|
| 23/WM/0166 | Other Identifier | NHS Research Ethics Committee Reference |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Northern Care Alliance NHS Foundation Trust | OTHER |
| European Commission | OTHER |
| Inbrain Neuroelectronics | INDUSTRY |
Not provided
Not provided
Not provided
Not provided
The goal of this clinical investigation of a medical device is to test the safety of graphene based electrodes when used during surgery for resection of brain tumors. The main questions that it aims to answer are:
Participants will undergo tumor surgery as usual with the study electrodes being tested alongside a standard monitoring system. If they are awake for part of their surgery they may be asked to complete specific tasks such as naming objects from a list modified for the study, to evaluate the capability to decode brain signals (exploratory objective). They will be monitored subsequently for any complications including undergoing an additional MRI scan 6 weeks after their surgery.
During surgical operations within the brain such as the removal of a tumor, electrodes are commonly used to map specific brain functions or monitor brain activity. These are most commonly flexible plastic devices with embedded metallic contacts that allow electrical activity in the brain to be detected and measured. They may also be used to stimulate precise areas of the brain to either trigger or block a response such as the contraction of a muscle. This allows the surgeon to define which regions of the brain are involved in controlling critical functions such as movement or speech so that these areas can be protected during the operation.
There remain limitations with the design and physical characteristics of commercially available electrodes for use during brain operations. These include the limited ability of conventional materials to fold over the complex shape of the brain and the need to use comparatively large metallic contacts to detect the tiny electrical signals. This study will be the first to introduce a new generation of electrodes which have been designed to overcome these limitations. They are extremely thin and flexible allowing them to follow the surface of the brain and to be used in locations within and around the brain for which the standard electrodes are unsuitable. The contact surfaces that detect electrical activity and enable and stimulate the brain have been replaced with graphene which is a novel carbon-based material. The use of graphene allows electrodes to be made that are more sensitive to the tiny electrical signals of the brain. This means that they can be much smaller and closer together providing increased detail in the recording and potentially enabling signals to be detected that would previously have required such long recordings that they could not be used to guide decision making during surgery.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Intervention Arm | Experimental | Patients with suspected gliomas (intrinsic primary brain tumors) in whom surgical resection under general anesthesia with neurophysiological monitoring or under awake conditions where language mapping is planned. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| INBRAIN Graphene Cortical Interface | Device | Study device to be evaluated intra-operatively alongside standard of care neurophysiological monitoring. |
|
| Measure | Description | Time Frame |
|---|---|---|
| To evaluate the preliminary safety of the investigational device for its intended use | All adverse events (including, but not limited to, adverse device events) | Through study completion, an average of 3 months |
| Measure | Description | Time Frame |
|---|---|---|
| Assess the ability of the device to record signals from the brain | Performance of detecting signals from the brain by sensing of electrical brain activity | During surgical procedure |
| Evaluate the ability of the device to provide functional stimulation of the brain |
| Measure | Description | Time Frame |
|---|---|---|
| Assess the quality of the recorded somatosensory evoked potentials (SEPs) - sensing part A (exploratory) | Assessing the quality of recorded brain activity by measuring signal to noise ratio (SNR) during stimulation of a peripheral nerve | During surgical procedure |
| Assess the quality of the recorded baseline brain activity - sensing part B (exploratory) |
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| David J Coope, PhD FRCS | Northern Care Alliance NHS Foundation Trust | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Manchester Centre for Clinical Neurosciences, Northern Care Alliance NHS Foundation Trust | Salford | Greater Manchester | M6 8HD | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 38212522 | Background | Viana D, Walston ST, Masvidal-Codina E, Illa X, Rodriguez-Meana B, Del Valle J, Hayward A, Dodd A, Loret T, Prats-Alfonso E, de la Oliva N, Palma M, Del Corro E, Del Pilar Bernicola M, Rodriguez-Lucas E, Gener T, de la Cruz JM, Torres-Miranda M, Duvan FT, Ria N, Sperling J, Marti-Sanchez S, Spadaro MC, Hebert C, Savage S, Arbiol J, Guimera-Brunet A, Puig MV, Yvert B, Navarro X, Kostarelos K, Garrido JA. Nanoporous graphene-based thin-film microelectrodes for in vivo high-resolution neural recording and stimulation. Nat Nanotechnol. 2024 Apr;19(4):514-523. doi: 10.1038/s41565-023-01570-5. Epub 2024 Jan 11. | |
| Result | Coope DJ, Lodwick S, Bambrough J, Karabatsou K, Maye H, Nambiar R, Donega M, Ruiz Sanchez-Beato M, Perez Vazquez A, Saiz-Alia M, Ortega P, Maull A, de la Cruz JM, Viana D, Garrido J, Kostarelos K. SURG-92: FIRST-IN-HUMAN STUDY OF A GRAPHENE CORTICAL INTERFACE FOR HIGH-PRECISION, HIGH-FIDELITY BRAIN-TO-TUMOR MAPPING REVEALS HIGH GAMMA ACTIVITY CAPABILITY: INTERIM ANALYSIS. Neuro-Oncology, Volume 27, Issue Supplement_5, November 2025, Page v415, https://doi.org/10.1093/neuonc/noaf201.1644 |
| Label | URL |
|---|---|
| European Union Graphene Flagship | View source |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D001932 | Brain Neoplasms |
| D005910 | Glioma |
| ID | Term |
|---|---|
| D016543 | Central Nervous System Neoplasms |
| D009423 | Nervous System Neoplasms |
| D009371 | Neoplasms by Site |
| D009369 | Neoplasms |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Performance of functional stimulation of the brain by inducing evoked motor responses measured as peripheral muscle electromyography (EMG) |
| During surgical procedure |
| Assess stability of sensing and stimulating electrodes | Stability of electrodes by evaluation of impedance measurements over time | During surgical procedure |
| Evaluate device usability - an assessment by questionnaire of the operating surgeon's impression of the suitability of the device for sensing and stimulation during brain tumor surgery | Study specific questionnaire to be completed by the operating surgeon including ease of handling, positioning and removal of the electrode. The study specific 'Device Usability' tool scores outcomes on a scale of 1-4 where 4 represents a favourable feature. | During surgical procedure |
Assessing the quality of recorded brain activity at rest (or under anaesthesia) evaluated as the power spectral density (PSD) |
| During surgical procedure |
| Assess the ability of detecting brain evoked responses during stimulation of the brain (exploratory) | Preliminary assessment of the ability of the device to detect changes in brain activity evoked in response to stimulation of distant but connected brain regions | During surgical procedure |
| Evaluate decoding capability from data recorded during language task (exploratory) | Preliminary evaluation of the ability to detect changes in brain activity that correspond to word or sound generation as the participant completes a standardized object naming task (quantified by classification accuracy) | During surgical procedure |
| Evaluate signal characteristics of tumour infiltrated brain regions (exploratory) | Preliminary evaluation of changes in the pattern of brain activity in healthy brain versus that infiltrated by tumour quantified by changes in the power spectral density (PSD) | During surgical procedure |
| D001927 |
| Brain Diseases |
| D002493 | Central Nervous System Diseases |
| D009422 | Nervous System Diseases |
| D018302 | Neoplasms, Neuroepithelial |
| D017599 | Neuroectodermal Tumors |
| D009373 | Neoplasms, Germ Cell and Embryonal |
| D009370 | Neoplasms by Histologic Type |
| D009375 | Neoplasms, Glandular and Epithelial |
| D009380 | Neoplasms, Nerve Tissue |