Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| Gangnam Severance Hospital | OTHER |
| Severance Hospital | OTHER |
Not provided
Not provided
Not provided
Not provided
This study aims to compare the diagnostic accuracy of the fractional flow reserve (FFR) model derived by machine learning based on optical coherence tomography (OCT) exam after coronary artery stent implantation with the wire-based FFR.
FFR and OCT exam are used for different purposes during percutaneous coronary intervention (PCI). The FFR is a decision-making tool to determine if additional procedures are necessary, while the OCT exam is used to optimize the stent procedure. The use of both tests provides additional information to help perform a excellent procedure, but it is more expensive and time-consuming.
Therefore, an OCT-derived machine learning FFR test may be helpful. Previous studies have demonstrated that OCT-based machine learning FFR before the procedure has shown good diagnostic performance in predicting FFR, irrespective of the coronary territory.
Despite the rapid development of technologies and tools for PCI, a significant number of patients experienced adverse events, such as recurrence of angina and silent ischemia despite angiographically successful PCI. Suboptimal PCI is a well-known independent prognostic factor for major cardiovascular accidents. Therefore, measuring post-PCI FFR immediately after stent implantation is crucial to optimize the procedure outcome and improve the patient's prognosis. Although the importance of measuring post-PCI FFR is gradually emerging, there is currently no model for OCT-based machine learning FFR that predicts FFR after stent insertion. In patients who underwent percutaneous coronary intervention using stents for ischemic heart disease, we will compare the diagnostic accuracy of the fractional flow reserve (FFR) model derived by machine learning based on optical coherence tomography (OCT) exam after coronary artery stent implantation with the wire-based FFR.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| OCT-based machine learning FFR | Diagnostic Test | OCT-based machine learning FFR and wire-based FFR |
| Measure | Description | Time Frame |
|---|---|---|
| Correlation of OCT-based machine learning FFR compared to wire-based FFR | Determining the diagnostic accuracy of CT-FFR values obtained by the new method compared with invasive coronary angiography with fractional flow reserve | 4 weeks |
| Measure | Description | Time Frame |
|---|---|---|
| Diagnostic performance of OCT-based machine learning FFR compared to wire-based FFR | Accuracy, sensitivity, specificity, positive predictive value, negative predictive value | 4 weeks |
| Diagnostic performance of OCT-based machine learning FFR according to the coronary artery (LAD, LCx or RCA) compared to wire-based FFR |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Among patients who underwent PCI for ischemic heart disease, those who underwent both OCT examination and pressure wire-based FFR after coronary artery stenting.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Oh-Hyun Lee, MD | Contact | +82-31-5189-8786 | Decenthyun@yuhs.ac |
| Name | Affiliation | Role |
|---|---|---|
| Jung-Sun Kim, MD, PhD | Severance Cardiovascular Hospital, Yonsei University College of Medicine | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Accuracy, sensitivity, specificity, positive predictive value, negative predictive value |
| 4 weeks |