The main goal in management of mandibular fractures is to restore the pre-injury form and function, with the least disability and shortest recovery period.
Currently there are a diversity of metallic hardware used for fixation of jaw fractures. However, the proper selection of the suitable technique is still a matter of debate.
The aim of the current study was to compare between the effect of two miniplates, 2.3 high profile Miniplates and three dimensional (3D) Miniplates for internal fixation treatment of mandibular para-symphyseal fractures.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| group (I) | ORIF was done using two 2.0 miniplates |
| |
| Group II | ORIF was done using 2.3 high profile miniplates |
| |
| Group III | ORIF was done using 3D miniplates. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| 2.0 miniplates | Device | 2.0 miniplates |
| |
| 2.3 high profile miniplates |
| Measure | Description | Time Frame |
|---|---|---|
| Surgery Time | measure the time of surgery from incision till closure with minutes | intraoperative |
| Measure | Description | Time Frame |
|---|---|---|
| complication | record the surgical complication operative and postoperative | 6 months |
| fracture stability | measure fracture stability from radiographs |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
patients who had suffered from a recent mandibular fractures in the symphyseal or parasymphyseal region which required Open Reduction with Internal Fixation (ORIF)
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Nermine Ramadan Mahmoud, PhD | Associated Professor of oral and maxillofacial surgery, Oral Surgery Department | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| October 6U | Cairo | 12566 | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30739640 | Background | Hu W, Agrawal M, Thadani S, Mukul SK, Sood R, Patel A, Dhanak R, Tailor S. Comparative evaluation of a single 2.0-mm AO locking reconstruction plate with conventional miniplate osteosynthesis for treatment of linear non-comminuted fractures of symphysis and parasymphsis region of the mandible. J Stomatol Oral Maxillofac Surg. 2019 Feb;120(1):11-15. doi: 10.1016/j.jormas.2018.10.002. Epub 2018 Oct 26. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D008337 | Mandibular Fractures |
| ID | Term |
|---|---|
| D007572 | Jaw Fractures |
| D008446 | Maxillofacial Injuries |
| D005151 | Facial Injuries |
| D006259 | Craniocerebral Trauma |
Not provided
Not provided
Not provided
Not provided
Not provided
| Device |
2.3 high profile miniplates |
|
| 3D miniplates | Device | 3D miniplates |
|
| 6 months |
| D020196 |
| Trauma, Nervous System |
| D009422 | Nervous System Diseases |
| D012887 | Skull Fractures |
| D050723 | Fractures, Bone |
| D014947 | Wounds and Injuries |