The Investigators have developed a camera based drill guidance system to improve the accuracy of surgical drilling. The aim of the study is to assess:
Accuracy in vivo Safety Acceptability of use amongst surgeons and theatre staff
This project is a collaboration between the Royal United Hospitals Bath and the Department of Mechanical Engineering at the University of Bath in the development of a drill guidance system to aid intra-operative surgical drilling in Orthopaedic and trauma surgery. The types of operation will include drilling into bones to place screws or wires to develop a track for passage of a screw, suture or other material. The project has been funded by an National Institute for Health Invention for Innovation Grant (NIHR i4i) over 3 years.
The Drill Guide System (DGS) has been developed so it can be attached to a surgical drill with the overall aim of improving the accuracy of surgical drilling of holes in bones. The drilling will be performed as standard, i.e. as required for any specific operation. The drill guide will be an adjunct to visual observation by the surgeon and fluoroscopy (peri-operative radiographs - X-rays). The surgeon can decide to not use the drill guide if it is considered to be hampering the operation. A camera and computer based system attached to a surgical drill will be used to improve drilling accuracy in an operating theatre
The Drill Guidance system has undergone rigorous testing and various laboratory trials with surgeons and operating staff as part of development of the design.
The final prototype will be used as part of a wider clinical trial involving Orthopaedic Surgeons at the Royal United Hospitals Bath and the Great Western Hospital, Swindon (within the NHS) to test the efficacy and value of the system during surgery.
The Investigators intend to recruit up to 30 surgical patients as part of the trial from two sites.
Background: It is recognised clinically and in laboratory studies that "freehand" drilling has appreciable inaccuracies. This risks misplacement of screws potentially compromising surgical outcome and increasing the risk of complications.
Furthermore, inaccurate initial drilling can lead to inaccurate subsequent drilling and so suboptimal positioning of the screw/wire with potential adverse outcomes and increased costs. The screw may be placed and then have to be changed. A new different length screw may be required with the first screw discarded with further costs.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Drill Guidance System | Experimental | Using a camera based system attached to a standard surgical drill the operating surgeon will use the DGS to drill with the aim of making the drilling more accurate. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Drill Guidance System (DGS) | Procedure | During a standard surgical procedure where a drill/k wire is being inserted the surgeon may choose (in advance) to supplement their drilling with use of the Drill Guidance System. This will be a supplement to normal practice. it is anticipated it will make surgery more accurate, swifter and safer. If however the surgeon is not finding the DGS useful it can be abandoned and standard drilling with X-ray guidance used |
| Measure | Description | Time Frame |
|---|---|---|
| Accuracy of placement of a screw or K wire in scaphoid bones | 1.Scaphoid fractures: "best practice" is screw placement in the central third of the scaphoid. This has been defined using CT scans in the Scaphoid Waist Internal Fixation for Fractures (SWIFFT) trial. When fixing a scaphoid fracture the surgeon will aim to place the screw in the central third of the scaphoid (standard) unless otherwise recorded. The screw position will be measured as central or off-centre (as in SWIFFT trial). The data from the SWIFFT trial will be used as a benchmark Measurements will be made with the computer measuring system on the Patient Archiving Communication System | 3 months |
| Accuracy of placement of a screw or K wire in other bones | Other fractures: at the point the surgeon plans to drill for the material screw/wire they will declare the planned exit point of the screw/wire using x and y co-ordinates in mm relative to a defined bony landmark prior to the use of the Drill Guide System. The screw/wire position on post-operative CT scans will be defined by the position of the tip of the screw/wire (or its projection to the outer cortex of the bone if it does not reach). This will be compared to the planned exit point to give distance and vector measurements Measurements will be made with the computer measuring system on the Patient Archiving Communication System | 3 months |
| Measure | Description | Time Frame |
|---|---|---|
| Length of material part of the procedure | The length of time performing the part of the surgical procedure when the DGS is used. There are no baseline data against which to compare. This should give an indicator of speed/ease of use. | Duration of the operation |
| Number of fluoroscopy (perioperative X-ray) images performed |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Adam Smith, FRCS (T and O) | Great Western Hospitals NHS Foundation Trust | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Royal United hospitals NHS Foundation Trust | Bath | United Kingdom | ||||
| Great Western Hospital MHS foundation Trust |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 30394951 | Background | Langeveld ARJ, Rustenburg CME, Hoozemans MJM, Burger BJ, Meuffels DE. To Improve Your Surgical Drilling Skills, Make Use of Your Index Fingers. Clin Orthop Relat Res. 2019 Jan;477(1):232-239. doi: 10.1097/CORR.0000000000000557. | |
| 27547423 | Background | Brioschi V, Cook J, Arthurs GI. Can a surgeon drill accurately at a specified angle? Vet Rec Open. 2016 Jul 14;3(1):e000172. doi: 10.1136/vetreco-2016-000172. eCollection 2016. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D050723 | Fractures, Bone |
| ID | Term |
|---|---|
| D014947 | Wounds and Injuries |
Not provided
Not provided
Participants undergoing orthopaedic Surgery
Not provided
Not provided
Not provided
Not provided
|
The number of fluoroscopy images performed peri-operatively whilst using DGS; for scaphoid fractures data will be compared with data from > 200 equivalent operations in the Scaphoid Waist internal fixation for fractures (SWIFFT) trial. For other operations the number of images taken when using the DGS will be recorded. There are no baseline data but the data can be used as an estimate of ease of use |
| Duration of the operation |
| Number of patients with treatment related adverse events as assessed by CTCAE v4.0 | The key adverse events we will review: Screw misplacement (prime complication).
Bone: Fracture mal-alignment post-operatively as shown on the initial post-operative radiographs and any subsequent radiographs/scans. Soft tissue: Possible soft tissue complications e.g. infection, and nerve and tendon injury, will be sought and recorded in the clinical notes at each standard clinical appointment | WIthin 3 months of surgery (the planned follow-up period) |
| Immediate acceptability to surgeons and theatre staff | Following consent the surgeons and theatre staff will be asked to complete a short questionnaire after each operation. | 3 months, i.e. duration of the study |
| Initial acceptability to surgeons and theatre staff | After the first 5 operations there will also be a debrief in person to get immediate feedback | 3 months, i.e. duration of the study |
| Overall acceptability to surgeons and theatre staff | Qualitative data will be collected via two focus groups held either face to face at each site or via Teams to include surgeons and theatre staff. These will collect user views on ease of use, problems encountered and areas for improvement. The focus groups will be recorded to allow for transcription and analysis of themes after all participants have completed their initial operation. Attendance at these focus groups will be optional for theatre staff and consent will be sought | 3 months |
| Swindon |
| United Kingdom |
| 32771106 | Result | Dias JJ, Brealey SD, Fairhurst C, Amirfeyz R, Bhowal B, Blewitt N, Brewster M, Brown D, Choudhary S, Coapes C, Cook L, Costa M, Davis T, Di Mascio L, Giddins G, Hedley H, Hewitt C, Hinde S, Hobby J, Hodgson S, Jefferson L, Jeyapalan K, Johnston P, Jones J, Keding A, Leighton P, Logan A, Mason W, McAndrew A, McNab I, Muir L, Nicholl J, Northgraves M, Palmer J, Poulter R, Rahimtoola Z, Rangan A, Richards S, Richardson G, Stuart P, Taub N, Tavakkolizadeh A, Tew G, Thompson J, Torgerson D, Warwick D. Surgery versus cast immobilisation for adults with a bicortical fracture of the scaphoid waist (SWIFFT): a pragmatic, multicentre, open-label, randomised superiority trial. Lancet. 2020 Aug 8;396(10248):390-401. doi: 10.1016/S0140-6736(20)30931-4. |