Our study investigates the accuracy and duration needed for 3D model registration using artifical intelligence (AI) assistance compared to conventional point-based registration. Manual segmentation of all cone beam computed tomography (CBCT) scans will be performed before the registration procedure.
CBCT images and intraoral scans will be screened following specific eligibility criteria. 16 CBCT images and intraoral scans that will meet the inclusion criteria will undergo manual segmentation via 3D medical image processing software. Afterward, point-based registration and AI-assisted registration will be performed by a single operator using specialized implant planning software. Then, the registration accuracy will be examined by measuring the distances between the three-dimensional models of CBCT data and intraoral scans. Also, the duration required for registration will be calibrated and recorded by a stopwatch.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| AI-assisted registration | Experimental | 3D model registration will be carried out using artificial intelligence |
|
| Point-based registration | Active Comparator | 3D model registration will be carried out using point-based approach |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| AI-assisted registration | Other | We will use artificial intelligence to register 3d model on intra-oral scan |
|
| Measure | Description | Time Frame |
|---|---|---|
| Registration accuracy | Distance between registered 3d model and CBCT in millimeters | immediately after the procedure |
| Measure | Description | Time Frame |
|---|---|---|
| Duration for registration | time taken for registration procedure | During the procedure |
Not provided
Inclusion Criteria:
CBCT scans for either the maxilla or mandible or both and intraoral scans or manual impressions with metal restorations.
Exclusion Criteria:
Scans without metal restorations.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Private maxillofacial digital lab | Cairo | Egypt |
no data will be shared
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Point-based registration | Other | We will use five references points or more to perform model registration |
|