Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The initial purpose of this study is to develop a prosthesis which is adjustable to use with a variety of patients in aquatic therapy. Aquatic therapy is a beneficial rehabilitation tool for individuals with limb loss. The pool environment offloads body weight, which can improve comfort on a residual limb and increase confidence in activities outside of the pool. The properties of water also assist in strengthening exercises and reducing pain.
Currently, most individuals do not have a prosthesis to use in the pool. Water specific prosthesis are often not covered by insurance and can be expensive. For someone that doesn't have a water specific prosthesis, they may not be able to do therapy tasks on two legs, limiting what activities or exercises can be performed. Through creating an adjustable prosthesis, it will allow persons with limb loss to have access to a water specific leg in a time efficient, cost effective, and safe manner for rehabilitation.
This study involves a novel prosthesis for use in aquatic therapy. This novel design will have an adjustable circumference, residual limb length, and height, allowing a greater number of patients to use the prosthesis.
The goal of this project is to create and conduct a preliminary usability evaluation of a novel adjustable prosthesis for use in aquatic therapy for persons with a lower limb amputation at the transtibial level (LLTTA). It is hypothesized that this prosthesis will benefit both the patient and the therapist during aquatic therapy sessions, which will be evaluated through the following aims:
Aim 1: Create a non-custom, adjustable prosthesis for use in aquatic therapy by individuals with limb loss at the transtibial level.
Aim 2: Perform a pilot study (n=3) to quantity the usability of the prosthesis as a therapy tool.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Adjustable Aquatic Therapy Prosthesis | Experimental | The prosthesis will be designed to be adjustable in circumference, residual limb length, and overall height. This will allow adjustability to accommodate most limb shapes. The design will also provide secure suspension, on both land and in the water. This will maximize safety for the patient and translate motion from the residual limb to the prosthesis. Additionally, the prosthesis design will include a comfortable fit and interface, protecting the participant's skin. Skin will be assessed prior to use, during initial fitting, and after each therapy session. Finally, the prosthesis will be test fit and used with maximum assistance from clinical staff, minimizing risk. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Adjustable Aquatic Therapy Prosthesis | Device | We will recruit up to three participants, who will attend up to two fitting appointments lasting up to one hour to assist in the design development. After the design of the prosthesis is completed, participants will attend three, 30-minute, aquatic therapy sessions with a physical therapist trained in aquatic therapy and utilize the prosthesis. |
| Measure | Description | Time Frame |
|---|---|---|
| System Usability Survey - Subject | The System Usability Survey is a reliable tool for measuring the usability of a device. It consists of a 10 item questionnaire with five response options for respondents; from Strongly agree to Strongly disagree. | Through study completion, an average of one year. |
| Measure | Description | Time Frame |
|---|---|---|
| Socket Comfort Score | Rating system to assess prosthesis socket comfort. Scale ranges from 0-10, with 0 being the least comfortable and 10 the most comfortable. | Through study completion, an average of one year. |
| System Usability Survey - Physical Therapist |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Shirley Ryan Ability Lab | Chicago | Illinois | 60611 | United States |
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Date | Date Unknown |
|---|---|---|
| Release | Jan 6, 2026 | |
| Reset | Jan 21, 2026 |
Not provided
Not provided
| Release Date | Unrelease Date | Unrelease Date Unknown | Reset Date | MCP Release Number |
|---|---|---|---|---|
| Jan 6, 2026 | Jan 21, 2026 |
Not provided
Not provided
Not provided
Not provided
Not provided
|
The System Usability Survey is a reliable tool for measuring the usability of a device. It consists of a 10 item questionnaire with five response options for respondents; from Strongly agree to Strongly disagree. |
| Through study completion, an average of one year. |