Stroke volume variation (SVV) is an indicator used to assess the patient's volume status. The FloTrac system (Edwards Lifesciences, Irvine, CA) continuously monitors cardiac output (CO) and SVV (SVV-FloTrac) by analyzing the systemic arterial pressure wave. Numerous studies have demonstrated that SVV-FloTrac serves as a reliable indicator of fluid responsiveness. However, its peripheral invasiveness raises concerns about susceptibility to reflecting waves, damping, and vascular tone influences.In contrast, Transthoracic electrical bioimpedance (BioZ.com™) offers a non-invasive approach for continuously monitoring various hemodynamic variables. In this study, the primary aim was to assess the agreement between simultaneously measured SVV-FloTrac and SVV-BioZ.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Flotrac Group | Active Comparator | In this group,an arterial catheter was inserted preoperatively. An indwelling radial artery catheter was connected to the hemodynamic monitoring system (EV1000; Edward Lifesciences Corp., Irvine, CA, USA) via FloTrac™ (Edwards Lifesciences Corp.) sensors. |
|
| BioZ Group | Experimental | In this group,haemodynamic parameters were collected simultaneously by the thoracic bioimpedance (BioZ.com™) monitoring. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Flotrac Group | Device | Haemodynamic parameters were collected simultaneously by the Flotrac monitoring. |
|
| Measure | Description | Time Frame |
|---|---|---|
| The capacity to predict fluid responsiveness. | After anesthesia induction, volume loading was initiated. For each volume loading step (VLS), 100 mL of colloid solution (6% hydroxyethyl starch) was administered over a 2-minute duration. The SVV was measured and recorded simultaneously by FloTrac (SVV-FloTrac) and Transthoracic electrical bioimpedance(SVV-BioZ). Volume loading steps (VLS) continued until no responsive VLS was observed. Responsive VLS, defined as an increase in Flotrac-SV by at least 5%, and nonresponsive VLS, characterized by no change or an increase in Flotrac-SV by less than 5%, were subsequently identified. Multiple analysis methods were used to determine the capacity to predict the fluid responsiveness of these two devices. | From anesthesia induction to the nonresponsive VLS about one hour. |
| Measure | Description | Time Frame |
|---|---|---|
| The agreement between simultaneously measured SVV-FloTrac and SVV-BioZ | After anesthesia induction, volume loading was initiated. For each volume loading step (VLS), 100 mL of colloid solution (6% hydroxyethyl starch) was administered over a 2-minute duration. The SVV was measured and recorded simultaneously by FloTrac (SVV-FloTrac) and Transthoracic electrical bioimpedance(SVV-BioZ). Volume loading steps (VLS) continued until no responsive VLS was observed. Responsive VLS, defined as an increase in Flotrac-SV by at least 5%, and nonresponsive VLS, characterized by no change or an increase in Flotrac-SV by less than 5%, were subsequently identified. Multiple analysis methods were used to determine the agreement of the two SVVs. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Diansan Su, Dr. | Contact | +862168383702 | diansansu@yahoo.com | |
| Yuwen Chen | Contact | +862168383702 | 15373748@qq.com |
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Renji Hospital, Shanghai Jiaotong University School of Medicine | Pudong | Shanghai Municipality | 200127 | China |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| BioZ Group | Device | Haemodynamic parameters were collected simultaneously by the thoracic bioimpedance (BioZ.com™)monitoring. |
|
| From anesthesia induction to the nonresponsive VLS about one hour. |