Use of intraosseous Doppler ultrasonography to study skeletal physiology ("Echo-Os Study"). Exploratory study before its use in space physiology.
Bones have a complex vascular network providing nutrients and oxygen to bone cells. The physiology of intraosseous blood circulation remains very little known to date, particularly in human. Human bone vascularization studying is very difficult because of a lack of simple tools for functional exploration of bone vascular perfusion. For blood flow studies, ultrasonography is best suited, allowing for dynamic non-invasive measures. Bone has until now been considered to stop ultrasound and therefore prevent any intraosseous measurements. From a physics viewpoint, bones conduct ultrasound waves well, but they are reflected differently compared to soft tissues. A specific analysis of the ultrasound returned by the bone, using specific correction factors, is therefore needed to interpret ultrasound signals, reconstruct an anatomical image, and extract physiological information. The system proposed in this study combines standard conventional low-frequency ultrasound probes with a specific analysis of ultrasound wave reflection. This system makes it possible to reconstruct an anatomical bone image and record the pulsatile signal of intraosseous vascular perfusion. The investigators will use this system to study the vascular reactivity induced by different physiological maneuvers.
This protocol proposes to study the following mechanisms of blood flow regulation at the level of tibia cortical bone: flow-mediated dilation induced by endothelium (with arterial occlusion test), vasoconstriction induced by sympathetic activation (with static handgrip test), and vasoconstriction induced by veno-arteriolar reflex (with venous occlusion test). This is a pilot study in physiology performed with healthy volunteers. This study will verify whether our intraosseous ultrasound system can properly measure physiological responses expected during these maneuvers. This protocol will also establish links between perfusion and bone architecture at tibial level.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| "Intraosseous ultrasonography" | Experimental | All subjects of each sub-protocol receive identical intervention (single group assignment for each of 2 sub-protocols). |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Intraosseous ultrasonography at tibia before, during, and after a physiological vascular stimulation (venous occlusions, arterial occlusion, handgrip) | Device | Timing for sub-protocol 1 (performed twice with 2-to-10-day interval): donning in supine position - rest 5 minutes - venous occlusion to 40 mmHg 3 minutes - rest 10 minutes - arterial occlusion to 200mmHg 2 minutes - post-occlusion period 10 minutes - rest 10 minutes - static handgrip 30% Maximum Voluntary Force 3 minutes - recovery 2 minutes and doffing. Timing for sub-protocol 2 (performed once). First, two sequences of intraosseous ultrasonography are performed in 45° head-up tilt position, with 10-minutes rest between sequences: donning and rest 5 minutes - occlusion to 80 mmHg 2 minutes - rest 10 minutes - occlusion to 180 mmHg 2 minutes - rest 10 minutes. During the first sequence, ultrasonography probe is positioned between middle and lower third of tibia for cortical bone measurement; during the second - at distal epiphysis of the tibia for trabecular bone measurement. After ultrasonography, subject is sitting down for 10 minutes for computed tomography. |
| Measure | Description | Time Frame |
|---|---|---|
| Change in tibial intracortical blood flow velocity, induced by physiological maneuvers in supine position (sub-protocol 1) | Velocity (mm/s) of intracortical blood flow at medial tibia level and its response to venous occlusion, arterial occlusion, handgrip, will be assessed via Ultrasound Vector Flow Mapping | before, at the end of venous occlusion (40 mmHg 3 minutes); before, at the end of arterial occlusion (200 mmHg 2 min); at 2, 5, and 10 min of post-occlusion period; before, at the end of handgrip (30% maximum voluntary force for 3 minutes) |
| Measure | Description | Time Frame |
|---|---|---|
| Change in leg skin and muscle blood flow, induced by physiological maneuvers in supine position (sub-protocol 1) | Leg skin blood flow (arbitrary units), leg muscle change in concentrations of oxy- and deoxy-hemoglobin (µmol/L), and their responses to venous occlusion, arterial occlusion, handgrip, will be assessed via Laser Doppler flowmetry and Near-Infrared Spectroscopy | before, at the end of venous occlusion (40 mmHg 3 minutes); before, at the end of arterial occlusion (200 mmHg 2 min); at 2, 5, and 10 min of post-occlusion period; before, at the end of handgrip (30% maximum voluntary force for 3 minutes) |
Not provided
Inclusion Criteria for sub-protocol 1:
Inclusion criteria for sub-protocol 2:
Inclusion criteria common for both sub-protocols:
Non-Inclusion criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Marc-Antoine CUSTAUD, Professor | University Hospital, Angers | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| CHU d'Angers | Angers | 49933 | France | |||
| CHU de Saint-Etienne |
Data will be shared upon reasonable request. Only de-identified data will be shared. Any data collected during the study may be shared. The protocol will be shared initially. Other documents may be shared at a later date upon request (e.g., the CRF to allow a collaborator to select the data they wish to access). The recipients of the data will be researchers. The data will be available for any purpose deemed relevant by the study investigator, based on a protocol provided by the requester, after verification of the obtaining of regulatory approvals, including the favorable opinion of an ethics committee.
The data will be shared after signing a negotiated data transfer agreement ( data access agreement), for the duration specified in the agreement.
The data will be made available via secure transfer (sharing platform approved by the university hospital: BlueFiles or Oodrive).
Not provided
Not provided
This small-n pilot study in physiology aims to validate the concept and serve a basis for in-depth studies on space physiology. Two clinical centers will be involved, each providing measurements in its area of expertise, and two sub-protocols with complementary objectives will be implemented:
Bone ultrasonography will be performed for both sub-protocols.
Not provided
Not provided
Not provided
Not provided
|
| Comparison of changes in tibial intracortical blood flow with changes in leg skin and muscle blood flow, induced by physiological maneuvers in supine position (sub-protocol 1) | Responses of leg intracortical, skin, and muscle blood flow to venous occlusion, arterial occlusion, and handgrip will be expressed as % baseline. Correlation of bone responses to skin and muscle responses (Pearson r) will be calculated. | before, at the end of venous occlusion (40 mmHg 3 minutes); before, at the end of arterial occlusion (200 mmHg 2 min); at 2, 5, and 10 min of post-occlusion period; before, at the end of handgrip (30% maximum voluntary force for 3 minutes) |
| Reproducibility of the change in tibial intracortical blood flow velocity, induced by physiological maneuvers in supine position (sub-protocol 1) | Measurements for sub-protocol 1 will be performed 2 times (visit 1 and visit 2 with 2-to-10-day interval), and Coefficient of variation in responses to physiological maneuvers (%) will be calculated | before, at the end of venous occlusion (40 mmHg 3 minutes); before, at the end of arterial occlusion (200 mmHg 2 min); at 2, 5, and 10 min of post-occlusion period; before, at the end of handgrip (30% maximum voluntary force for 3 minutes) |
| Change in tibial intracortical blood flow velocity, induced by occlusion maneuvers in +45° head up tilt position (sub-protocol 2) | Velocity (mm/s) of intracortical blood flow at distal tibia level, and its responses to proximal cuff compression steps of 80 mmHg and 180 mmHg, will be assessed via Ultrasound Vector Flow Mapping. | Ultrasonography acquisition sequences of 5 secondes will be performed before and during each occlusions. |
| Change in tibial ultradistal bone blood flow velocity, induced by occlusion maneuvers in +45° head up tilt position (sub-protocol 2) | Velocity (mm/s) of intracortical blood flow at distal tibia level, and its responses to proximal cuff compression steps of 80 mmHg and 180 mmHg, will be assessed via Ultrasound Vector Flow Mapping. | Ultrasonography acquisition sequences of 5 secondes will be performed before and during each occlusions. |
| Comparison of intraosseous ultrasonography and computed tomography for Cortical bone thickness characterisation (sub-protocol 2) | Cortical thickness at distal tibia (mm) will be measured via peripheral quantitative computed tomography and via intraosseous ultrasonography. Correlation (Pearson r) between measurements will be calculated | First, intraosseous ultrasonography is performed at +45° head up tilt position (30 minutes for all occlusion steps), then the subject sits down and tomography is performed (10 minutes) |
| Comparison of intraosseous ultrasonography and computed tomography for Cortical bone porosity characterisation (sub-protocol 2) | Cortical density (mg/cm3) via peripheral quantitative computed tomography and cortical ultrasound propagation velocity (m/s) via intraosseous ultrasonography will be measured at distal tibia. Correlation (Pearson r) between measurements will be calculated. | First, intraosseous ultrasonography is performed at +45° head up tilt position (30 minutes for all occlusion steps), then the subject sits down and tomography is performed (10 minutes) |
| Saint-Etienne |
| 42055 |
| France |
| ID | Term |
|---|---|
| D001157 | Arterial Occlusive Diseases |
| ID | Term |
|---|---|
| D014652 | Vascular Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided