Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The goal of this clinical trial was to compare the clinical and radiographic success of laser versus formocresol pulpotomy in primary molars. The main questions it aimed to answer was:
• Does laser pulpotomy has higher clinical and radiographic success rate as formocresol pulpotomy in primary molars?
Participants were selected according to eligibility criteria to undergo pulpotomy for their lower primary molars under local anesthesia using one of the following techniques:
In all teeth, local anaesthesia was administered using 7.0 mg/kg 4% articane + 1: 100,000 epinephrine (with a maximum total dosage of 500 mg)
- Rubber dam isolation was done.
Access cavity preparation:
In all groups, caries removal was done with a sterile #330 high-speed bur, and coronal access cavity preparation was done with a sterile #4 high-speed round bur using high speed hand piece and water coolant. The access cavity was then refined using a sterile high-speed fissure bur. LASER operating parameters: Figure (10)
After achieving complete haemostasis pulp stumps were treated according to each group: Group1: (control group)
A cotton pellet that was moistened with 1:5 diluted bottle of FC (Formacresol, PREVEST DenPro, Digiana, Jammu, India) was placed over the pulp stumps for 5 minutes. After removal of the cotton, the fixed pulp stumps were capped with reinforced zinc oxide and eugenol base (Zinconol, PREVEST DenPro, Digiana, Jammu, India). Group2: (Diode LASER group)
All patients, parents and clinical staff were requested to wear appropriate eye protection goggles during laser application, Figure (12). After achieving hemostasis, pulp stumps was treated with Diode LASER (980 nm).If hemostasis was not achieved, the process was repeated one more time until adequate hemostasis was achieved, Figure (15, 16). Diode LASER radiation (wavelength 980 nm) was delivered to the canal orifices with a special handpiece and fiber glass of 200 μm diameter, Figure (13), the parameters were set at: Figure (14) Emission mode: Pulsed contact mode Time: 2 seconds. Power: 2 Watt power with average power of 1 Watt and total energy of one spot, corresponding to two minutes and 31 seconds exposure was 4.0 J/cm 2. Group3: (Erbium:Chromium,YSGG LASER group) Pulp tissues in this group were treated with Erbium:Chromium,YSGG LASER (2780 nμ). (Waterlase Biolase®, Biolase, Inc., San Clemente, California, USA) Once the pulp chamber was opened, the laser tip was placed into the pulp chamber using for approximately 15 seconds. In most instances, this was repeated three times. If hemostasis was not achieved, the process was repeated one more time until adequate hemostasis was achieved. Er: Cr, YSGG LASER radiation (wavelength 2780 nμ) was delivered with a special handpiece, and a tip: MZ 10- 6 mm, Zip Tip, to the canal orifices.
LASER operating parameters:
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Formocresol | Active Comparator |
| |
| Diode laser | Experimental |
| |
| Er:CrYSGG | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Diode laser | Procedure |
| ||
| Er:CrYSGG |
| Measure | Description | Time Frame |
|---|---|---|
| Clinical and radiographic success | Clinical success criteria:
1. No external root resorption; 2. No internal root resorption; 3. No inter-radicular bone resorption. 4. No Widening of the periodontal ligament space. 5. No periapical bone resorption. | 18 months |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Dina Hamdy | Ain Shams University | Principal Investigator |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D054023 | Lasers, Semiconductor |
| C031025 | formocresol |
| ID | Term |
|---|---|
| D007834 | Lasers |
| D055096 | Optical Devices |
| D004864 | Equipment and Supplies |
| D055618 | Radiation Equipment and Supplies |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Formocresol | Procedure |
|