The study aims at evaluating effectiveness of noninvasive cardiometry in assessment of cardiac parameters in critically ill patients in respiratory ICU in comparison to invasive methods as indirect fick's and thermodilution methods using pulmonary artery catheter.
Patients and methods
A. Study setting The study will be conducted in Assiut University Hospital, in respiratory intensive care unit.
B. Study design This study is a cross-sectional study
C.Methods
Firstly, invasive methods:
The Fick method is a "gold standard" measurement of cardiac output. This method is based on the principle described by Adolfo Fick in 1870, according to which the total uptake or release of a substance by an organ is the product of the blood flow through the organ and the arteriovenous concentration difference of the substance.
The oxygen uptake in the lungs is the product of the blood flow through the lungs and the arteriovenous oxygen content difference. Therefore, the cardiac output, CO, can be calculated using the equation:
CO= VO2/(CaO2-CvO2)
Where VO2 is the oxygen consumption by the lungs and (CaO2-CvO2) is the arteriovenous difference in oxygen. VO2 can be compensated for, based on calculated body surface area (BAS), using equation of = 125 × BSA. The arteriovenous difference is computed by receiving samples of arterial oxygen saturation through arterial blood gases, and mixed venous oxygen saturation through receiving blood from the pulmonary artery using PAC.
Another method is thermodilution, this method uses a special thermistor tipped catheter (Swan-Ganz catheter) inserted from a central vein into the pulmonary artery. A normal saline (temperature 0 degrees Celsius) is injected into the right atrium from a proximal catheter port. This solution causes a decrease in blood temperature, which is measured by a thermistor placed in the pulmonary artery catheter. The pulmonary artery catheter is attached to the cardiac output computer, which displays a curve and calculates output and derived indices automatically.
Secondly, noninvasive methods Electrical cardiometry will be attached to patient using four electrodes. Two electrodes will be on the left side of the neck and the two other electrodes on the left side of the chest opposite to the xiphoid process at the mid-axillary line.
This allow for the continuous measurement of the changes of electrical conductivity within the thorax. By sending low amplitude, high frequency electrical current through the thorax, the resistance that the current faces (due to several factors) is measured. Through advanced filtering techniques, Electrical Cardiometry (EC) is able to isolate the changes in conductivity created by the circulatory system.
This can determine the stroke volume, cardiac output and other hemodynamic indcies.
Another noninvasive method which is used in assessment of cardiac parameters is echocardiography.
D. Action plan and outcomes
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| cardiometry | Device | cardiometry is noninvasive method, while swan ganz is invasive method in hemodynamic parameters assessment |
|
| Measure | Description | Time Frame |
|---|---|---|
| Effectiveness of noninvasive cardiometry | To know the effectiveness of noninvasive cardiometry - icon cardiometry - in determining patient's cardiac output and other hemodynamic parameters as stroke volume and cardiac index in comparison to invasive methods using swan ganz catheter as ficks method and thermodilution method. This will be done through computing sensitivity, specificity and accuracy of noninvasive cardiometry. | 1 year |
| Measure | Description | Time Frame |
|---|---|---|
| Abnormal cardiac output in critically ill patients | To know the prevalence of cardiac output abnormalities in critically ill patients in respiratory ICU. | 1 year |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Respiratory ICU patients
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 15072778 | Background | Hett DA, Jonas MM. Non-invasive cardiac output monitoring. Intensive Crit Care Nurs. 2004 Apr;20(2):103-8. doi: 10.1016/j.iccn.2004.01.002. | |
| 29489212 | Background | Rodriguez Ziccardi M, Khalid N. Pulmonary Artery Catheterization. 2023 Aug 28. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. Available from http://www.ncbi.nlm.nih.gov/books/NBK482170/ |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D002303 | Cardiac Output, Low |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
| D012816 | Signs and Symptoms |
| D013568 | Pathological Conditions, Signs and Symptoms |
Not provided
Not provided
Not provided
Not provided
Not provided
| 20218415 | Background | Evans DC, Doraiswamy VA, Prosciak MP, Silviera M, Seamon MJ, Rodriguez Funes V, Cipolla J, Wang CF, Kavuturu S, Torigian DA, Cook CH, Lindsey DE, Steinberg SM, Stawicki SP. Complications associated with pulmonary artery catheters: a comprehensive clinical review. Scand J Surg. 2009;98(4):199-208. doi: 10.1177/145749690909800402. |
| 24646113 | Background | Siebenmann C, Rasmussen P, Sorensen H, Zaar M, Hvidtfeldt M, Pichon A, Secher NH, Lundby C. Cardiac output during exercise: a comparison of four methods. Scand J Med Sci Sports. 2015 Feb;25(1):e20-7. doi: 10.1111/sms.12201. Epub 2014 Mar 20. |