The goal of this randomized crossover trial is to compare the results of a stationary and a mobile ergospirometry system in 20 healthy endurance trained participants. The main question it aims to answer is to investigate the differences in VO2-measurements between the mobile K5 and the stationary Quark ergospirometry system.
Participants will do a maximal ramp test followed by a sub maximal step test with 6 stages on two different days.
20 endurance trained men and/or women will be recruited. A screening will be done before starting with the test protocol on the treadmill to ensure the suitability of the participants. The test protocol includes two parts. The first part is a maximal ramp test (+0.6km/h each minute until exhaustion). The second part includes a step test with 6 sub maximal stages - each lasting 5 minutes - at 50%, 55%, 60%, 70%, 75% and 80% of the maximal velocity achieved in the first part. There will be a short break between the ramp and the step test. The stationary and the mobile system are tested on 2 separate days with a break of 1-3 days in between. On the second day, procedure will be exactly the same for the participants.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Endurance Trained Athletes |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Ergometric test | Diagnostic Test | Ramp test followed by a step test, both with ergospirometry |
|
| Measure | Description | Time Frame |
|---|---|---|
| VO2 peak | Maximal oxygen consumption (VO2) peak values during the ramp test | during the last 30 seconds of the ramp test |
| Measure | Description | Time Frame |
|---|---|---|
| VO2 | oxygen consumption (VO2) values during step test in steady state | during the last 2 minutes of the step test |
| VCO2 | carbon dioxide production (VCO2) values during step test in steady state |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
healthy endurance trained male or female older than 18 years
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Swiss Paraplegic Centre | Nottwil | Canton of Lucerne | 6207 | Switzerland |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| during the last 2 minutes of the step test |
| Ventilation | Ventilation during step test in steady state | during the last 2 minutes of the step test |
| breathing frequency | breathing frequency values during step test in steady state | during the last 2 minutes of the step test |