The goal of this prospective study is to validate the superior vena cava collapsibility index (SVC-CI) as a predictor of fluid responsiveness during laparotomy and open aortic surgery. The SVC-CI and patients' response to fluid will be assessed based on transesophageal echocardiography.
The study has three arms, in order to validate SVC-CI under the conditions of laparotomy, aortic cross clamping and high PEEP levels. One of the study arms will be an active comparator arm.
The data obtained from this study may help physicians guide intraoperative fluid therapy in a more efficient manner, in order to decrease perioperative mortality.
Patients undergoing high-risk non-cardiac surgery, including acute laparotomies and open aortic surgery, are at high risk of postoperative complications and adverse cardiovascular events. Perioperative fluid therapy is a factor which is strongly associated with postoperative outcomes. To avoid both hypovolemia and excessive fluid administration a strategy of goal-directed fluid therapy (GDFT) has been coined. Traditionally in the setting of operating rooms GDFT relied on stroke-volume variation (SVV) measured by hemodynamic monitors, based on uncalibrated pulse contour cardiac output analysis (uAPCO). However in the described cohort of patients uAPCO methods show a significantly increased measurement error, which is mainly attributed to dynamic changes in peripheral vascular tone. Furthermore, frequent occurrence of arhytmias in those patients limits the use of SVV and all other dynamic indices of fluid responsiveness based on those methods. Superior vena cava collapsibility index (SVC-CI) is a parameter which is devoid of the above mentioned limitations. It relies on respiratory variation of superior vena cava during the respiratory cycle and is therefore reliable in patients with irregular heart rhytm and seems independent from changing afterload conditions.
The main purpose of this study is to validate SVC-CI in patients undergoing controlled mechanical ventilation during laparotomies and during open aortic surgery, with focus on elevated PEEP levels and aortic cross-clamping.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patients undergoing open aortic surgery with sinus rhythm | Experimental | Arm to validate SVC-CI during open aortic surgery with special focus of predicting FR during aortic cross clamping (n=50). |
|
| Patients undergoing laparotomy and high PEEP | Experimental | Arm designed to validate SVC-CI during laparotomy, ventilated with high PEEP levels (8-10cmH2O). PEEP will be raised transiently during measurements (n=50). |
|
| Patients undergoing laparotomy with standard ventilatory settings | Active Comparator | Arm designed as an active comparator with standard (protective) ventilatory settings (n=50). Tidal volumes (Vt) will be set for 8ml/kg. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Superior vena cava collapsibility index | Diagnostic Test | After induction of general anaesthesia following interventions will be performed.
Several volume trials per patient will be allowed, until safety criteria are met. In such cases further testing will be stopped. |
| Measure | Description | Time Frame |
|---|---|---|
| Fluid responsiveness | Fluid responsiveness was defined as an increase of 10% or more of cardiac output (CO) following an administered 250ml fluid bolus. Changes in CO will be estimated using changes in left ventricle outflow tract velocity time integral (LVOT-VTI) assessed by transesophageal echocardiography to avoid errors associated with measuring LVOT area, which is necessary to calculate CO. | Directly after infusing fluid bolus. |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Patients who are deemed to be at risk of harm due to excessive fluid administration:
Medical contraindication to the use of transesophageal echocardiography:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Tomasz Królicki, MD, PhD | Uniwersytecki Szpital Kliniczny w Opolu | Study Chair |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Opole University Hospital | Opole | 45-401 | Poland |
The data will be shared in open access, however no plan has been designed.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| PEEP elevation | Other | A transient elevation of positive end-expiratory pressure (PEEP) will be applied, in order to validate SVC-CI in the setting of elevated PEEP. A PEEP level of 8-10cmH2O will be applied for 1 minute prior to every measurement of SVC-CI. Then the previous PEEP level will be reinstated. |
|
| ID | Term |
|---|---|
| D017548 | Echocardiography, Transesophageal |
| ID | Term |
|---|---|
| D004452 | Echocardiography |
| D057791 | Cardiac Imaging Techniques |
| D003952 | Diagnostic Imaging |
| D019937 | Diagnostic Techniques and Procedures |
| D003933 | Diagnosis |
| D014463 | Ultrasonography |
| D006334 | Heart Function Tests |
| D003935 | Diagnostic Techniques, Cardiovascular |
Not provided
Not provided