Purpose: This study aimed to assess the 3-dimentional wear )3D) (volumetric loss) and 2-dimentional wear (2D) (vertical loss) and surface hardness of ready-made (prefabricated) and CAD/CAM milled artificial denture teeth.
material and methods: In a cross-over study design, ten completely edentulous patients were randomly chosen for this study and given two complete dentures. The first complete denture was constructed with pre-fabricated teeth. The second complete denture was constructed with CAD\CAM milled teeth. The complete denture teeth were 3D scanned at the time of insertion (T0), after three months (T3), and after six months (T6) of denture insertion. Utilizing 3D surface superimposition techniques, the vertical (2D wear), and Volumatic (3D wear) material loss were measured. The hardness of the teeth were evaluated at the time of denture insertion (T0) then after 6 months (T6) of denture insertion by Vickers hardness test. Statistical analysis was done using SPSS software. Paired groups were compared by paired t test. Significant difference was considered if P ≤ 0.05.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| complete denture with prefabricated artificial teeth | Other | complete denture constructed with prefabricated artificial teeth and inserted in the patient mouth to be used for 3, 6 months |
|
| complete denture with CAD\CAM milled artificial teeth | Other | complete denture constructed with CAD\CAM Milled artificial teeth and inserted in the patient mouth to be used for 3, 6 months |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| surface hardness test for denture teeth | Other | surface hardness test of denture teeth at insertion then after 6 months of use |
|
| Measure | Description | Time Frame |
|---|---|---|
| wear resistance of denture artificial teeth | 2D, 3D wear of denture teeth were measured using denture scanning and superimposition of the sanning at insertion to that after 3, 6 months using Exocad soft ware | 6 months after denture use |
| surface hardness of the denture artificial teeth | the measurement of surface hardness was done using Vickers's test. this measurements was done at insertion then after 6 months | 6 months after denture use |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| faculty of dentistry, Mansoura univeristy | Al Mansurah | Egypt |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 41073957 | Derived | Abozaed HW, Ali SA, Mostafa AZ. Patient satisfaction and oral health-related quality of life for prefabricated teeth versus CAD-CAM milled acrylic resin denture teeth. A crossover clinical trial. BMC Oral Health. 2025 Oct 10;25(1):1601. doi: 10.1186/s12903-025-06834-1. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| wear resistance of denture teeth measurement | Other | 2D, Vertical wear, 3D Volumetric wear were measured for denture teeth |
|