The objective of this observational study is to evaluate the primary stability of dental implants and the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS)
Primary implant stability plays a key role in providing osseointegration. Higher insertion torque indicates higher primary stability. However, the effect of increased insertion torque on patient pain levels has not been clearly demonstrated. Several methods for measuring primary stability have been defined so far. Insertion torque, periotest measurements, and resonance frequency analysis are mostly preferred due to their ease of use and non-invasiveness.
The aim of the present study is to evaluate the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS) and to assess the relationship between insertion torque, periotest measurements, and resonance frequency analysis.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| High insertion torque group | Active Comparator | Fifteen patients (eight females and seven males) with a single-tooth deficiency bilaterally in the molar region of the lower jaw were included in the study. Implant placement with high insertion torque was planned on one side of the jaw. The implant drills were applied as recommended by the company. To achieve high insertion torque, the single-use final drill from the implant box was not used in the high torque group. |
|
| Low insertion torque group | Active Comparator | Fifteen patients (eight females and seven males) with a single-tooth deficiency bilaterally in the molar region of the lower jaw were included in the study. Implant placement with low insertion torque was planned on the otherside of the jaw. The implant drills were applied as recommended by the company. To achieve low insertion torque, the single-use final drill was applied two times. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Dental Implantation with high torque | Procedure | Fifteen patients with bilateral single-tooth loss in the posterior mandible will be included in the study. One implant was randomly placed with high insertion torque in each patient. A total of 15 implants will be placed, and insertion torque values will be recorded. |
| Measure | Description | Time Frame |
|---|---|---|
| Pain levels assessed with the visual analogue scale (VAS) | Patients will be asked to record the number of painkillers taken each day and evaluate their pain levels using a 0-10 VAS form before and after the operation. A score of 0 indicated no pain while 10 indicated the worst pain possible. A VAS score of 1-3 indicated mild pain, 4-6 indicated moderate pain, and 7-10 indicated very severe pain. | 7 days |
| Measure | Description | Time Frame |
|---|---|---|
| Insertion torque values | After the implant slots were prepared, the coronal part of the implants (MIS Implant Technologies, Bar Lev Industrial Park, Israel) were placed into the slots at 25 rpm without irrigation until the coronal part was at the same level with the ridge top. The maximum insertion torque was recorded while the implants were placed with the help of a physiodispenser that can measure the insertion torque (Kavo Expertsurg lux physiodispenser, KaVo Dental GmbH, Biberach, Germany). |
Not provided
Inclusion Criteria:
Exclusion Criteria
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D003757 | Dental Implantation |
| ID | Term |
|---|---|
| D013516 | Oral Surgical Procedures, Preprosthetic |
| D019647 | Oral Surgical Procedures |
| D013514 | Surgical Procedures, Operative |
| D019919 | Prosthesis Implantation |
Not provided
Not provided
Randomized controlled study
Not provided
Not provided
Not provided
|
| Dental Implantation with low torque | Procedure | Fifteen patients with bilateral single-tooth loss in the posterior mandible will be included in the study. One implant was randomly placed with low insertion torque in each patient. A total of 15 implants will be placed, and insertion torque values will be recorded. |
|
| 1 day |
| Periotest measurements | Measurements were made with the Periotest (Siemens AG, Bensheim, Germany) device and recorded as PTV (perio test value). | 1 day |
| Resonance frequency analysis values | A SmartPeg (Integration Diagnostics AB; Gothenburg, Sweden) suitable for the implant was attached to measure primary implant stability with radiofrequency. Radiofrequency analysis was performed in both mesiodistal and buccolingual directions with the Osstell Mentor (Integration Diagnostics AB; Gothenburg, Sweden) device and the measurements were recorded. | 1 day |
| D003813 | Dentistry |
| D011476 | Prosthodontics |