Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
The excessive use of screens particularly amongst digital gamers can adversely impact the health of the surface of the eyes with symptoms and signs of surface damage. While strategies including limiting screen time exist, these may be ineffective given the widespread rise of digital device use and gaming culture in the modern era. There is limited evidence for the protective effect of lubricating eyedrops on the ocular surface for handheld console and computer gamers.
The aim of this study is to investigate the protective effect of a lubricating eyedrop (TheaLoz Duo) on the surface of the eyes in handheld console and computer gamers. The main question it aims to answer is whether TheaLoz Duo could protect the surface of the eyes from dessication and alleviate symptoms of dry eye disease in handheld console and computer gamers.
Participants will receive either the lubricating eyedrop first for 1 month, followed by a control condition (no eyedrops) for another month, or the other way round. Participants will attend 3 visits in total, each separated by 1 month apart. During each visit, routine clinical assessments of the front of the eye will be conducted. Subsequent findings from this timely study will help improve care of the surface of the eyes for a growing population of gamers worldwide.
This study will be a randomized, outcome assessor-masked, cross-over clinical study to assess the potential impact of TheaLoz Duo lubricating eyedrop on symptoms and signs of dry eye disease in handheld console and computer gamers. All visits will be conducted at the Aston Dry Eye Clinic in Aston University, Birmingham, United Kingdom.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| TheaLoz Duo in first month, crossover to control condition in second month | Experimental | The TheaLoz Duo eyedrop will be prescribed and used by the participant for 1 month. At the second visit 1 month later, the participant will return the TheaLoz Duo eyedrop bottle, and no eyedrops will be prescribed, and the participant monitored following 1 month. At the third and final visit 1 month later, the participant will return for a follow-up visit. |
|
| Control condition in first month, crossover to TheaLoz Duo in second month | Active Comparator | No eyedrops will be prescribed and the participant monitored for 1 month. At the second visit 1 month later, the participant will return and be prescribed TheaLoz Duo eyedrop and used by the participant for another 1 month. At the third and final visit 1 month later, the participant will return the TheaLoz Duo eyedrop bottle and complete the study visits. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| TheaLoz Duo Eyedrop | Drug | TheaLoz Duo lubricating eyedrop contains 3.0% trehalose and 0.15% sodium hyaluronate as active ingredients and will be used by participants everyday to instill 1 drop, 4 times a day in both eyes. |
| Measure | Description | Time Frame |
|---|---|---|
| Change from Baseline in Ocular Surface Disease Index scores to the First Follow-Up 1 Month After Baseline | Validated questionnaire for assessing dry eye symptom severity and impact. Scores range from 0 indicating no dry eye symptoms to 100 with severe dry eye symptoms and impact (Schiffman et al, 2000). | Baseline to 1 month after baseline |
| Change from First Follow-Up in Ocular Surface Disease Index scores to the Second Follow-Up 1 Month After the First Follow-Up | Validated questionnaire for assessing dry eye symptom severity and impact. Scores range from 0 indicating no dry eye symptoms to 100 with severe dry eye symptoms and impact (Schiffman et al, 2000). | First follow-up to 1 month after the first follow-up |
| Measure | Description | Time Frame |
|---|---|---|
| Change from Baseline in Computer Vision Syndrome Questionnaire scores to the First Follow-Up 1 Month After Baseline | Validated questionnaire for assessing the severity and frequency of eye strain when using a computer. The scores range from 0 to 32 (SeguĂ Mdel et al, 2015). | Baseline to 1 month after baseline |
Not provided
Inclusion criteria:
Exclusion criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| James S Wolffsohn, PhD | Contact | +441212044400 | dryeye@aston.ac.uk |
| Name | Affiliation | Role |
|---|---|---|
| James S Wolffsohn, PhD | Aston University | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| School of Optometry, Aston University | Recruiting | Birmingham | West Midlands | B4 7ET | United Kingdom |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 28736342 | Background | Wolffsohn JS, Arita R, Chalmers R, Djalilian A, Dogru M, Dumbleton K, Gupta PK, Karpecki P, Lazreg S, Pult H, Sullivan BD, Tomlinson A, Tong L, Villani E, Yoon KC, Jones L, Craig JP. TFOS DEWS II Diagnostic Methodology report. Ocul Surf. 2017 Jul;15(3):539-574. doi: 10.1016/j.jtos.2017.05.001. Epub 2017 Jul 20. | |
| 10815152 | Background |
Not provided
Not provided
The investigators are planning to deposit deidentified datasets in a publicly and freely available data repository site.
Not provided
Data will be available at the end of the study before publication of the findings in a peer-reviewed journal.
The dataset will be publicly and freely available.
Not provided
Not provided
| ID | Term |
|---|---|
| D015352 | Dry Eye Syndromes |
| ID | Term |
|---|---|
| D007766 | Lacrimal Apparatus Diseases |
| D005128 | Eye Diseases |
Not provided
Not provided
Participants will be randomized to receive either the active treatment (TheaLoz Duo) or control condition (no eyedrops) at the first visit. The cross-over will occur one month following the first phase, followed by another month when the participant will be assessed again at the final visit.
Not provided
Not provided
Not provided
|
| Change from First Follow-Up in Computer Vision Syndrome Questionnaire scores to the Second Follow-Up 1 Month After the First Follow-Up |
Validated questionnaire for assessing the severity and frequency of eye strain when using a computer. The scores range from 0 to 32 (SeguĂ Mdel et al, 2015). |
| First follow-up to 1 month after the first follow-up |
| Change from Baseline in Visual Acuity to the First Follow-Up 1 Month After Baseline | Subjective measure of visual acuity using Logarithm of the Minimum Angle Resolution (logMAR) scoring, ranging from -0.30 which signify the ability to be able to resolve the smallest letters, to 1.00 which signify the ability to resolve only the largest letters. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Visual Acuity to the Second Follow-Up 1 Month After the First Follow-Up | Subjective measure of visual acuity using Logarithm of the Minimum Angle Resolution (logMAR) scoring, ranging from -0.30 which signify the ability to be able to resolve the smallest letters, to 1.00 which signify the ability to resolve only the largest letters. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Tear Meniscus Height to the First Follow-Up 1 Month After Baseline | Measure of the volume of tears in mm using the Oculus Keratograph 5M instrument. An average of 3 measurements is obtained. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Tear Meniscus Height to the Second Follow-Up 1 Month After the First Follow-Up | Measure of the volume of tears in mm using the Oculus Keratograph 5M instrument. An average of 3 measurements is obtained. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Lipid Layer Pattern to the First Follow-Up 1 Month After Baseline | Subjective grading of the appearance of the lipid layer pattern as a surrogate measure of its thickness using the Oculus Keratograph 5M instrument. This ranges from Grade 1 indicating very thin lipid layer to Grade 6 indicating very thick lipid layer. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Lipid Layer Pattern to the Second Follow-Up 1 Month After the First Follow-Up | Subjective grading of the appearance of the lipid layer pattern as a surrogate measure of its thickness using the Oculus Keratograph 5M instrument. This ranges from Grade 1 indicating very thin lipid layer to Grade 6 indicating very thick lipid layer. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Bulbar Conjunctival Hyperaemia to the First Follow-Up 1 Month After Baseline | Automated objective grading of the bulbar conjunctival redness using the Oculus Keratograph 5M instrument. This ranges from Grade 0 indicating no redness to Grade 4 indicating substantial redness. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Bulbar Conjunctival Hyperaemia to the Second Follow-Up 1 Month After the First Follow-Up | Automated objective grading of the bulbar conjunctival redness using the Oculus Keratograph 5M instrument. This ranges from Grade 0 indicating no redness to Grade 4 indicating substantial redness. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Blink Rate to the First Follow-Up 1 Month After Baseline | Manual subjective count of the number of blinks using the Oculus Keratograph 5M instrument. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Blink Rate to the Second Follow-Up 1 Month After the First Follow-Up | Manual subjective count of the number of blinks using the Oculus Keratograph 5M instrument. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Fluorescein Corneal Staining to the First Follow-Up 1 Month After Baseline | Subjective grading of the amount of corneal staining using fluorescein instillation, cobalt blue light illumination and the Oxford grading scale. This ranges from 0 with no staining to 5 with intense staining. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Fluorescein Corneal Staining to the Second Follow-Up 1 Month After the First Follow-Up | Subjective grading of the amount of corneal staining using fluorescein instillation, cobalt blue light illumination and the Oxford grading scale. This ranges from 0 with no staining to 5 with intense staining. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Lissamine Green Bulbar Conjunctival Staining to the First Follow-Up 1 Month After Baseline | Subjective grading of the amount of bulbar conjunctival staining using lissamine green instillation, white light illumination and the Oxford grading scale. This ranges from 0 with no staining to 5 with intense staining. | Baseline to 1 month after baseline |
| Change from First Follow-Up in Lissamine Green Bulbar Conjunctival Staining to the Second Follow-Up 1 Month After the First Follow-Up | Subjective grading of the amount of bulbar conjunctival staining using lissamine green instillation, white light illumination and the Oxford grading scale. This ranges from 0 with no staining to 5 with intense staining. | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Lissamine Green Lid Wiper Epitheliopathy to the First Follow-Up 1 Month After Baseline | Subjective grading of the amount of lid wiper epitheliopathy using lissamine green instillation and white light illumination. This grading ranges from 0 with no lid wiper epitheliopathy to 4 with severe lid wiper epitheliopathy | Baseline to 1 month after baseline |
| Change from First Follow-Up in Lissamine Green Lid Wiper Epitheliopathy to the Second Follow-Up 1 Month After the First Follow-Up | Subjective grading of the amount of lid wiper epitheliopathy using lissamine green instillation and white light illumination. This grading ranges from 0 with no lid wiper epitheliopathy to 4 with severe lid wiper epitheliopathy | First follow-up to 1 month after the first follow-up |
| Change from Baseline in Meibography Meiboscore to the First Follow-Up 1 Month After Baseline | Subjective grading of the amount of Meibomian gland loss using infrared imaging and the Pult meiboscore. This grading ranges from 0 with no gland loss to 4 with severe gland loss (Pult and Reide-Pult, 2013). | Baseline to 1 month after baseline |
| Change from First Follow-Up in Meibography Meiboscore to the Second Follow-Up 1 Month After the First Follow-Up | Subjective grading of the amount of Meibomian gland loss using infrared imaging and the Pult meiboscore. This grading ranges from 0 with no gland loss to 4 with severe gland loss (Pult and Reide-Pult, 2013). | First follow-up to 1 month after the first follow-up |
| Number of Participants with Dry Eye Disease at Baseline | The number of participants diagnosed with dry eye disease according to established clinical diagnostic criteria (Wolffsohn et al, 2017). | At baseline |
| Number of Participants with Dry Eye Disease at First Follow-Up | The number of participants diagnosed with dry eye disease according to established clinical diagnostic criteria (Wolffsohn et al, 2017). | At first follow-up 1 month after baseline |
| Number of Participants with Dry Eye Disease at SecondFollow-Up | The number of participants diagnosed with dry eye disease according to established clinical diagnostic criteria (Wolffsohn et al, 2017). | At second follow-up 1 month after first follow-up |
| Schiffman RM, Christianson MD, Jacobsen G, Hirsch JD, Reis BL. Reliability and validity of the Ocular Surface Disease Index. Arch Ophthalmol. 2000 May;118(5):615-21. doi: 10.1001/archopht.118.5.615. |
| 23108007 | Background | Pult H, Riede-Pult B. Comparison of subjective grading and objective assessment in meibography. Cont Lens Anterior Eye. 2013 Feb;36(1):22-7. doi: 10.1016/j.clae.2012.10.074. Epub 2012 Oct 27. |
| 25744132 | Background | Segui Mdel M, Cabrero-Garcia J, Crespo A, Verdu J, Ronda E. A reliable and valid questionnaire was developed to measure computer vision syndrome at the workplace. J Clin Epidemiol. 2015 Jun;68(6):662-73. doi: 10.1016/j.jclinepi.2015.01.015. Epub 2015 Jan 28. |