Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
This study was performed to compare between the effects of different occlusal materials used for all on four implant supported mandibular fixed prosthesis with PEEK framework.
Methods of Evaluation
1- Occlusal force analysis using digital occlusal device (occluscan).
The evaluation periods will be done at time of insertion (T0),6 month (T1),12 month(T2) and 18 month(T3) after framework insertion.
thirty completely edentulous patients will be selected for the study from the outpatient's clinic of Prosthodontic Department, Faculty of Dentistry, Mansoura University.
The patients will be selected according to the following criteria:
Exclusion criteria included:
1- Systemic disorders affecting bone (such as uncontrolled diabetes mellitus and osteoporosis).
2- Local or general contraindication for surgical procedures. 3- History of chemotherapy or radiation therapy to the head and neck area. 4- Habits as heavy smoking and alcoholism. 5- Patients with T.M.J disorders or poor neuromuscular co-ordination.
For all patient's conventional complete denture will be constructed and adjusted for insertion and delivery.
A cone beam C.T will be done for each patient to determine the bone quality and quantity.
A surgical stent will be designed and fabricated to allow accurate implant placement of two axially placed anterior implants and two distally tilted posterior implants by about 30 degree to support mandibular overdenture.
Surgical placement of implant fixtures on its sites will be done.
Multiunit abutments were screwed to the distal implants.
The conventional mandibular denture will be modified to act as immediate fixed prosthesis that replace lost teeth and gingival tissues.
After three months, the Polyetheretherketone (PEEK) frame that connects the four implants will be constructed using digital scan and CAD CAM manufacturing.
The milled frame was fixed to the metal caps using DTK cement
The BioHPP framework will have prepared abutments projecting from it. After processing, the framework will be tried in patient mouth for passive fit.
Wax interocclusal record was made to establish the occlusal relationship with opposing teeth.
According to the artificial teeth, the patients will be divided into two groups:
The inner surface of the artificial teeth will be etched using hydrophosphoric acid then silane will be used and light cured resin cement will be used for cementation of the artificial teeth to the PEEK framework
The occlusal scheme used with the opposing maxillary denture will be lingualized balanced occlusion to enhance the stability of mandibular implant overdentures.
Methods of evaluation:
1- Occlusal force analysis using digital occlusal device (occluscan).
The evaluation periods will be done at time of insertion (T0), 6 month (T1), 12 month (T2) and 18 month (T3) after framework insertion.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| PEEK framework veneered with nanocomposite resin(visio-lign) | Experimental | patients recieved 4 implants according to All on 4 concept then peek framework was delivered and veneered with nano-composite resin (visio-lign) as an occlusal material |
|
| PEEK framework veneered with zirconia crowns | Experimental | patients recieved 4 implants according to All on 4 concept then peek framework was delivered and veneered with zirconia crowns as an occlusal material |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| dental implants | Procedure | 4 dental implants placed in the mandible according to all-on 4 concept |
|
| Measure | Description | Time Frame |
|---|---|---|
| occlusal stability | Occlusal stability using digital occlusal device (occlusense) | The evaluation periods will be done at time of insertion (T0), 6 month (T1), 12 month (T2) and 18 month (T3) after framework insertion |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Mansoura U Faculty of dentistry | Mansoura University Faculty of Dentistry, Prosthodontics department | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mansoura University, Faculty of dentistry | Al Mansurah | Egypt |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| ID | Term |
|---|---|
| D015921 | Dental Implants |
| ID | Term |
|---|---|
| D003764 | Dental Materials |
| D001697 | Biomedical and Dental Materials |
| D017266 | Dental Prosthesis |
| D011476 | Prosthodontics |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| peek framework | Procedure | peek framework screwed to multi-unit abutments of 4-implants |
|
| visio-lign nano composite | Procedure | peek framework veneered with nano composite (visio-lign) as an occlusal material |
|
| zirconia crowns | Procedure | peek framework covered with zirconia crowns as an occlusal material |
|
| D003813 |
| Dentistry |
| D019736 | Prostheses and Implants |
| D004864 | Equipment and Supplies |
| D008420 | Manufactured Materials |
| D013676 | Technology, Industry, and Agriculture |