This multicenter, non-comparative clinical trial, led by two principal investigators in Spain, aims to evaluate the safety and performance of a robotic assistant, based on a electromechanical tracking system, in patients requiring transpedicular screw fixation. The study, conducted in two different hospital centers, involves patients with vertebral fractures, spinal stenosis, kyphosis, and other related conditions. The primary objective is to determine screw accuracy by assessing the degree of screw invasion into the pedicle using the Gertzbein-Robbins scale, with a target of achieving 96% acceptable screw placement. Trained radiologists will evaluate the screw invasion into the pedicle. The study is scheduled to span 12 months and each intervention includes a 1-month follow-up. Throughout this time frame, patients will undergo regular assessments, and outcomes will be closely monitored.
Multicenter non-comparative clinical trial.
This interventional study aims to assess the safety and performance of a robotic assistant, based on a electromechanical tracking system, in patients requiring transpedicular screw fixation.The primary focus is on overcoming the limitations of traditional minimally invasive surgeries and enhancing the accuracy of pedicle screw placement, especially within the complex pedicle region adjacent to the spinal canal.
The study design is a prospective interventional trial conducted in two hospital centers in Spain, with two principal investigators leading the investigation. Patients requiring transpedicular screw fixation will be recruited. The robotic assistant will be employed to facilitate transpedicular screw fixation. The system aims to improve accuracy and safety in screw placement, in comparison with conventional techniques used.
Patients will include individuals with spinal fractures, spinal stenosis, kyphosis, and other conditions requiring transpedicular screw fixation. Two principal investigators in Spain will lead the recruitment process.
The study aims to answer several key questions:
Trained radiologists will play a crucial role in evaluating the accuracy of screw placement, focusing on the degree of invasion into the pedicle using the Gertzbein-Robbins scale. The study is set to span a duration of 12 months,during which patients will undergo regular assessments, and outcomes will be closely monitored. The inclusion of the electromechanical tracking system in the robotic assistant adds a technological dimension to the investigation, contributing to advancements in the field of minimally invasive spinal surgeries.
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Patient with spinal condition who requires a transpedicular fixation intervention. | Experimental | Patient with spinal condition (vertebral fractures, spinal stenosis, kyphosis, among others) who requires a intervention for spinal fusion with pedicle screws. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Robot assisted spinal transpedicular fixation | Procedure | Surgical technique which joins two or more vetebrae with screws and rods to prevent any relative movement between them. It is a major surgery that usually lasts several hours and in which the patient is subjected to general anesthesia. The screws to be placed go through a narrow area of the vertebra known as the pedicle. Each patient will undergo a singular intervention. |
| Measure | Description | Time Frame |
|---|---|---|
| Grade of screw invasion into the pedicle based on Gertzbein-Robbins scale (A-E grade) | Grade A: Screw position within the pedicle. Grade B: Cortical breakage ≤2mm. Grade C: Cortical breakage ≤4mm. Grade D: Cortical breakage ≤6mm. Grade E: Cortical breakage >6mm. | 1 month follow-up |
| Measure | Description | Time Frame |
|---|---|---|
| Patient characteristics - Demographic dates - Sex (Male/Female) | 3 months | |
| Patient characteristics - Demographic dates - Age (years) | 3 months | |
| Patient characteristics - Demographic dates - Weight (kg) |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Nicolás M. Samprón Lebed, Neurosurgeon | Hospital Donostia | Principal Investigator |
| Iñigo C. Pomposo Gastelu, Neurosurgeon | Hospital de Cruces | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Cyber Surgery | Donostia / San Sebastian | Gipuzkoa | 20001 | Spain |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
|
| 3 months |
| Patient characteristics - Demographic dates - Height (cm) | 3 months |
| Patient characteristics - BMI | W [kg]/H [m2] | 3 months |
| Patient characteristics - Spinal Region (Thoracic/Lumbar/Sacral) | 3 months |
| Patient characteristics - Vertebrae for study (T1...T12/L1...L5/S1-S2) | 3 months |
| Patient characteristics - Comobidities | Charlson Index (1-6 pts) | 3 months |
| Patient characteristics - Number of screws to be placed | 3 months |
| Implant characteristics - Planned vertebrae | 3 months |
| Implant characteristics - Laterality (L/R) | 3 months |
| Implant characteristics - Screw orientation in sagittal plane (Cranial/Caudal/Neutral) | 3 months |
| Implant characteristics - Screw orientation in axial plane (Medial/Lateral/Neutral) | 3 months |
| Implant characteristics - Screw dimensions - Screw diameter (mm) | 3 months |
| Implant characteristics - Screw dimensions - Screw length (mm) | 3 months |
| Clinical Intervention - Surgical technique (open/MIS) | 3 months |
| Clinical Intervention - ASA Anaesthesia (I-IV) | 3 months |
| Clinical Intervention - Radiation emission - Time (sec.) | 3 months |
| Clinical Intervention - Radiation emission - Dosage (mGy) | 3 months |
| Clinical Intervention - Blood loss - Intraoperatice blood loss (ml) | 3 months |
| Clinical Intervention - Blood loss - Number of gauzes used | 3 months |
| Clinical Intervention - Blood loss - Postoperative drainage (ml) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery - Total (min.) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery per stages - Power on and disposition (min.) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery per stages - Planification (min.) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery per stages - Image registration (min.) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery per stages - Positioning (min.) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery per stages - Surgery (min.) | 3 months |
| Clinical Intervention - Blood loss - Duration of surgery per stages - Removal and power off (min.) | 3 months |
| Clinical Intervention - Blood loss - Postoperative stay (days) | 1 month follow-up |
| System performance - Number of image registration | 1 month follow-up |
| System performance - Number of screws not inserted using the robotic assistant | 1 month follow-up |
| System performance - Number of colisioned screws | 1 month follow-up |
| System performance - Number of not reachable screws | 1 month follow-up |
| System performance - Fiducial Registration Error, FRE (mm) | 3 months |
| System performance - Screw position deviation - Spatial deviation in XY plane (mm) | 1 month follow-up |
| System performance - Screw position deviation - Spatial deviation in XZ plane (mm) | 1 month follow-up |
| System performance - Screw position deviation - Spatial deviation in YZ plane (mm) | 1 month follow-up |
| System performance - Screw position deviation - Angular deviation in XY plane (deg.) | 1 month follow-up |
| System performance - Screw position deviation - Angular deviation in XZ plane (deg.) | 1 month follow-up |
| System performance - Screw position deviation - Angular deviation in YZ plane (deg.) | 1 month follow-up |
| Adverse Events, AE | 1 month follow-up |
| Severe Adverse Events, SAE | 1 month follow-up |
| ID | Term |
|---|---|
| D016103 | Spinal Fractures |
| D013130 | Spinal Stenosis |
| D007738 | Kyphosis |
| ID | Term |
|---|---|
| D013124 | Spinal Injuries |
| D019567 | Back Injuries |
| D014947 | Wounds and Injuries |
| D050723 | Fractures, Bone |
| D013122 | Spinal Diseases |
| D001847 | Bone Diseases |
| D009140 | Musculoskeletal Diseases |
| D013121 | Spinal Curvatures |
Not provided
Not provided