Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Class |
|---|---|
| The Scientific and Technological Research Council of Turkey | OTHER |
Not provided
Not provided
Not provided
Not provided
Not provided
The aim of our study is to examine the effects of balance exercises performed in virtual and real environments on visual-spatial attention and mental rotation in healthy young adult individuals using EEG brain oscillations.
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Video-based balance games group | Experimental |
| |
| Balance exercises group | Experimental |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Video-based games intervention | Other | These games are applied via using Nintendo Wii 1st - 2nd Week Applications
|
| Measure | Description | Time Frame |
|---|---|---|
| EEG - event related oscillations | In our research, EEG recordings will be made with the Brain Vision Recorder (Brainproduct, Munich, Germany) device. Recording will be made on 30 channels with 0.1-250 Hz band pass and 500 sample rate features. An elastic cap with 32 Ag-AgCl electrode placement will be used as the cap. The placement of electrodes will be made according to the international 10-20 system and includes FP1, FP2, F7, F3, FZ, F4, F8, FT7, FC3, FCZ, FC4, FT8, T7, C3, CZ, C4, T8, TP7, CP3, CPZ. Recordings will be taken from the electrodes CP4, TP8, P7, P3, PZ, P4, P8, O1, OZ and O2. Additionally, two connected electrodes (A1+A2) will be placed on the front of both earlobes as a reference, and the ground electrode will be placed on the back of the right earlobe. In addition, electrodes placed in the medial upper part and lateral orbital part of the left eye will be used for EOG recording. During shooting, care will be taken to ensure that the impedance values of the electrodes are below 10 kΩ. | Baseline-6 week |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Affiliation | Role |
|---|---|---|
| Bahar Güntekin, Prof. Dr. | Medipol University | Study Director |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Istanbul Medipol University | Istanbul | Beykoz | 34820 | Turkey (Türkiye) |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Balance exercises | Other | 1st-2nd Week Applications On a flat-hard surface;
|
|