This study is aimed to compare between titanium framework and soft metal framework used for mandibular All-on-4 implant supported prosthesis.
The evaluation will be for:
Patient grouping:
• 20 Patients will be classified into 2 equal groups, first group will receive 4 implants placed according to All on 4 concept supporting screw retained prosthesis with titanium framework manufactured by dry milling technique, second group will receive 4 implants placed according to All on 4 concept supporting screw retained prosthesis with metal framework manufactured by dry milling/post sintering of Co-Cr soft metal blocks.
The evaluation will be for:
• Bone level changes around implant using periapical x-ray after 6 months and 12 months and 18 months from insertion of fixed prosthesis.
This study will compare between titanium framework and soft metal framework used for mandibular All-on-4 implant supported prosthesis regarding bone level changes around implant using periapical x-ray after 6 months and 12 months and 18 months from insertion of fixed prosthesis.
Patient selection Twenty patients will be selected from the out-patient clinic of Prosthodontic Department, Faculty of Dentistry, Mansoura University seeking for prosthetic rehabilitation.
All patients will be informed about all surgical and prosthetic procedures that will be done. Also; they will sign the consent form of ethical committee of faculty of dentistry.
All implants will be installed in the edentulous mandible in each target positions according to their arrangements guided by stereolithographic stent.
Patient grouping:
The evaluation will be for:
• Bone level changes around implant using periapical x-ray after 6 months and 12 months and 18 months from insertion of fixed prosthesis.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| titanium framework manufactured by dry milling technique | Experimental | All patients will have titanium framework manufactured by dry milling technique and occlusal material made from PMMA FPD |
|
| metal framework manufactured by dry milling/post sintering of Co-Cr soft metal blocks | Experimental | All patients will have metal framework manufactured by dry milling/post sintering of Co-Cr soft metal blocks and occlusal material made from PMMA FPD |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| CADCAM | Other | Milling of Final prosthesis over dental implants using CADCAM milling machine |
|
| Measure | Description | Time Frame |
|---|---|---|
| Peri-implant crestal bone resorption | Crestal bone level will be evaluated by Periapical x-ray | at time of insertion of prosthesis procedure T(0), 6 months after insertion T(6), 12 months after insertion T(12), 18 months after insertion (T18) |
Not provided
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Mohamed Shady, MD | Contact | 01005225707 | Mohamedshady@mans.edu.eg |
| Name | Affiliation | Role |
|---|---|---|
| Mohamed Shady, MD | Mansoura University Faculty of Dentistry, Prosthodontics department | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Mansoura University, Faculty of dentistry | Recruiting | Al Mansurah | Egypt |