Guidelines for patients having first-time implants advocate that even when heart function is only mildly impaired, modern pacing approaches should be utilised to avoid the potentially damaging effects of RV pacing to preventing symptoms from pacing induced or worsened cardiomyopathy.
However, once a traditional (RV) pacemaker is implanted, development of impaired heart function does not prompt a device upgrade. Even at the end of battery life, physicians simply replace it like-for-like.
This trial tests whether such patients have better symptoms and quality of life if changed to a modern physiological pacing strategy from the traditional RV pacing approach.
In this crossover trial, participants will be upgraded to a physiological pacing strategy.
After their procedure, they will have a one-month run-in period to recover from the procedure (their pacemaker will be programmed to continued RV pacing).
They will be have 2 one-month blinded time periods, randomised to physiological pacing or right ventricular pacing alternately. They will subsequently undergo two six-month blinded randomised time periods.
Patients will document symptoms monthly on a mobile phone application or computer. At the end of each time period, they will have measurements of heart function, a walking test and quality-of-life questionnaires including the SF-36 questionnaire.
The investigators hypothesise that upgrading to physiological pacing strategies will improve patients' quality of life.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Physiological Pacing (Conduction System Pacing or Biventricular Pacing) | Experimental | The approach for physiological pacing will be either His bundle pacing or left bundle pacing at the operator's discretion. If both of these are not achieved biventricular pacing will be performed. |
|
| Right Ventricular Pacing | Active Comparator | Right ventricular pacing (apical or septal lead locations as per the implanting physicians' normal practice) |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Physiological Pacing Upgrade (Conduction System Pacing or Biventricular Pacing) | Device | The approach for physiological pacing upgrade will be either His bundle pacing or left bundle pacing at the operator's discretion. If both of these are not achieved biventricular pacing will be performed. |
| Measure | Description | Time Frame |
|---|---|---|
| SF-36 (Short Form 36 Health Survey Questionnaire) Physical Component Summary | From date of baseline, until end of trial follow-up at fourteen months post-baseline |
| Measure | Description | Time Frame |
|---|---|---|
| Left ventricular ejection fraction | (% ejection fraction) | From date of baseline, until end of trial follow-up at fourteen months |
| Left ventricular end systolic volume | (millilitres) |
Not provided
Patients with an RV pacemaker and LVEF 35-50% and a high burden of right ventricular pacing (>40%) who are clinically indicated for a cardiac resynchronisation therapy upgrade procedure and:
Exclusion Criteria:
Not provided
Not provided
Not provided
Not provided
Not provided
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Aya Khalil | Contact | 07749576830 | a.khalil@imperial.ac.uk | |
| Nandita Kaza, MRCP | Contact | 07749576830 | n.kaza@imperial.ac.uk |
| Name | Affiliation | Role |
|---|---|---|
| Daniel Keene, PhD | Imperial College London | Principal Investigator |
| Nandita Kaza, MRCP | Imperial College London | Study Director |
| Matthew Shun-Shin, PhD |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Royal Papworth Hospital | Recruiting | Cambridge | United Kingdom |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
| Type | Includes Protocol | Includes SAP | Includes ICF | Document Label | Document Date | Document Uploaded Date | Document File Name |
|---|---|---|---|---|---|---|---|
| Prot_SAP | Yes | Yes | No | Study Protocol and Statistical Analysis Plan | Jul 29, 2024 |
Not provided
Not provided
Not provided
Not provided
Not provided
|
| Continued RV Pacing (Right Ventricular Pacing) | Device | Right ventricular pacing (apical or septal lead locations as per the implanting physicians' normal practice). |
|
| From date of baseline, until end of trial follow-up at fourteen months |
| Minnesota Living with Heart Failure Questionnaire | From date of baseline, until end of trial follow-up at fourteen months |
| Six-minute walk test | Measured in distance in metres | From date of baseline, until end of trial follow-up at fourteen months |
| Atrial fibrillation | (atrial fibrillation percentage burden as measured by pacemaker device - %) | From date of baseline, until end of trial follow-up at fourteen months |
| Patient preference based on blinded symptomatic preference | At 2 months following baseline and 14 months following baseline visit |
| EQ-5D Questionnaire | EQ-5D is the name of the instrument and is not an acronym. The EQ-5D-5L consists of 2 pages: the EQ-5D descriptive system and the EQ 'visual analogue scale' (EQ VAS). The descriptive system is made up of 5 sections: mobility, self-care, usual activities, pain/discomfort and anxiety/depression. Each has 5 levels: no problems, slight problems, moderate problems, severe problems and extreme problems. The EQ VAS records the patient's self-rated health on a vertical visual analogue scale, where the endpoints are labelled 'The best health you can imagine' and 'The worst health you can imagine'. The VAS can be used as a quantitative (numerical) measure of health outcome that reflect the patient's own judgement. A high score on the VAS means a better outcome. A low score on the VAS means a worse outcome. | From date of baseline, until end of trial follow-up at fourteen months post-baseline visit |
| Patient symptoms assessed on a scale of 0-100 monthly | This questionnaire will be sent to participants on a monthly basis for the duration of the study | From date of baseline, until end of trial follow-up at fourteen months post-baseline visit |
| Safety endpoints | Device infections (requiring device extraction), pacing thresholds, need for lead revision or reimplantation, generator change, haematoma and pneumothorax | From device implant date, assessed up to 15 months at the end of the trial (including a one-month run-in period post-procedure prior to the first baseline visit) |
| SF-36 (Short Form 36 Health Survey Questionnaire) Overall Score | From date of baseline, until end of trial follow-up at fourteen months post baseline visit |
| SF-36 (Short Form 36 Health Survey Questionnaire) Individual Component Scores | From date of baseline, until end of trial follow-up at fourteen months post baseline visit |
| BNP (B-type natriuretic peptide) | B-type natriuretic peptide blood test | From date of baseline, until end of trial follow-up at fourteen months post baseline visit |
| Imperial College London |
| Study Director |
| St. Richard's Hospital - University Hospitals Sussex | Recruiting | Chichester | United Kingdom |
|
| University Hospitals Coventry and Warwickshire NHS Trust, | Recruiting | Coventry | United Kingdom |
|
| Croydon University Hospital - Croydon Health Services | Recruiting | Croydon | United Kingdom |
|
| Glenfield Hospital | Recruiting | Leicester | United Kingdom |
|
| Hammersmith Hospital | Recruiting | London | United Kingdom |
|
| King's College Hospital | Recruiting | London | United Kingdom |
|
| St Bartholomew's Hospital - Barts Health NHS Trust | Recruiting | London | United Kingdom |
|
| Oxford University Hospitals | Recruiting | Oxford | United Kingdom |
|
| University Hospitals Southampton | Recruiting | Southampton | United Kingdom |
|
| Great Western Hospitals | Recruiting | Swindon | United Kingdom |
|
| Worthing Hospital - University Hospitals Sussex | Recruiting | Worthing | United Kingdom |
|
| Sep 4, 2024 |
| Prot_SAP_002.pdf |
| ID | Term |
|---|---|
| D006333 | Heart Failure |
| ID | Term |
|---|---|
| D006331 | Heart Diseases |
| D002318 | Cardiovascular Diseases |
Not provided
Not provided
| ID | Term |
|---|---|
| D058406 | Cardiac Resynchronization Therapy |
| ID | Term |
|---|---|
| D002304 | Cardiac Pacing, Artificial |
| D004599 | Electric Stimulation Therapy |
| D013812 | Therapeutics |
Not provided
Not provided