The goal of this clinical trial is to test the BrightPoint Epidural device as the first system to use multispectral reflectometry to find the epidural space in lumbar neuraxial procedures requiring epidural needle. The main questions it aims to answer are:
Participants will undergo a neuraxial procedure in which the attending anesthesiologist will use the BrightPoint epidural device to form an opinion on its effectiveness in confirming epidural space access.
There have been few improvements to the LOR technique from a device standpoint in recent years, and those that options do exist have not achieved widespread clinical use. The devices that do exist are variations on pressure sensors, some automate the "resistance" by placing various systems in place to apply a pressure to the plunger so that it will inject when the epidural space is accessed without the practitioner doing it themselves. This concept is represented by devices such as the Epimatic syringe from Vygon. Others improve on this concept by monitoring the pressure required to inject a set volume of fluid, thus being able to differentiate between true and false losses, as during false losses the pressure will increase as more fluid is injected. This system is represented by the CompuFlo Device by Milestone Scientific.
The BrightPoint Epidural device is the first system that utilizes multispectral reflectometry in order to identify the epidural space. This technology has the theoretical benefit over pressure-based systems of being able to identify and differentiate between different issue types (muscle, ligament, bone) as the needle is advanced towards the epidural space. Lumoptik, the company behind the BrightPoint Epidural device, is an early-stage startup based in Cleveland, Ohio. The main questions this trial aims to answer are:
This trial is being conducted to improve our current standard of care in neuraxial placement of loss-of-resistance. While the loss of resistance technique is tried and true, especially in experienced hands, complications such as dural punctures, misplaced epidurals, patchy epidurals, neurologic injuries, and intravascular catheters can occur even in experienced hands. All of which can cause significant patient morbidity and costs to the healthcare system, and as is shown in the Lacombe attached, the effects of dural puncture can be long lived for the patient. There can also be a steep learning curve when learning the technique, with the frequency of inadvertent dural punctures significantly higher in the early stages of learning the procedure. Therefore, we as a specialty are obligated to evaluate potential improvements to our current way of practice to reduce the burden to our patients from the complications of our interventions.
Not provided
Not provided
Not provided
Not provided
Not provided
| Label | Type | Description | Intervention Names |
|---|---|---|---|
| Group 1 | Attending anesthesiologists who are trained in epidural placement will perform neuraxial procedures (CSEs, Epidural, Spinals through an epidural needle) utilizing loss of resistance with saline in conjunction with the Lumoptik BrightPoint Epidural Device. The Lumoptik device will be connected between a standard commercially available 17G or 18G, 3.5-inch epidural needle and a saline filled loss of resistance syringe. The anesthesiologist will view the Lumoptik BrightPoint visual display in real time as the epidural procedures are performed. The LOR epidural procedure using haptic feedback will be used as the primary confirmation of correct needle placement in the epidural space. Graphic and color circle information from the Lumoptik visual display will be used as a secondary confirmation of epidural placement. |
|
| Name | Type | Description | Arm Group Labels | Other Names |
|---|---|---|---|---|
| Group 1 - Lumoptik BrightPoint Epidural Device | Device | Participants will undergo a neuraxial procedure to measure loss of resistance with saline in conjunction with the Lumoptik BrightPoint Epidural Device. |
| Measure | Description | Time Frame |
|---|---|---|
| Real time confirmation of epidural space with loss of resistance technique | On the post-procedure questionnaire, the anesthesiologist will report about whether the device identified epidural space in agreement with loss of resistance technique. If no, the outcome will be recorded as either a false positive (device signaled epidural space while needle was not in epidural space) or false negative (device did not signal epidural space while needle was in epidural space). | Post-operation (after the surgery is complete) |
| Measure | Description | Time Frame |
|---|---|---|
| Clinical (anesthesiologist) opinions on Lumoptik Bright Point Epidural device | On the post-procedure questionnaire, the anesthesiologist will give their opinion about the device following their use of the study device. | Post-operation (after the surgery is complete) |
| Color graphics aid in the identification of needle tips. |
Not provided
Inclusion Criteria:
Exclusion Criteria:
Not provided
Not provided
Patients scheduled to have surgery at the Hospital for Special Surgery that will require a lumbar neuraxial procedure requiring an epidural needle.
| Name | Role | Phone | Extension | |
|---|---|---|---|---|
| Pa Thor, PhD | Contact | 646-797-8535 | thorp@hss.edu | |
| Maya Tailor | Contact | 646-714-6828 | tailorm@hss.edu |
| Name | Affiliation | Role |
|---|---|---|
| Michael Singleton, MD | Hospital for Special Surgery, New York | Principal Investigator |
| Facility | Status | City | State | ZIP | Country | Contacts |
|---|---|---|---|---|---|---|
| Hospital for Special Surgery | Recruiting | New York | New York | 10021 | United States |
| PubMed Identifier | Type | Citation | Retractions |
|---|---|---|---|
| 35338103 | Result | Lacombe A, Downey K, Ye XY, Carvalho JCA. Long-term complications of unintentional dural puncture during labor epidural analgesia: a case-control study. Reg Anesth Pain Med. 2022 Jun;47(6):364-369. doi: 10.1136/rapm-2021-103266. Epub 2022 Mar 25. | |
| 35474399 | Result | Eley VA, Abeypala W, Kelley A, Kumta N, Chin A. Recognized and unrecognized dural punctures in 12,981 labor epidurals: an audit of management. J Anesth. 2022 Jun;36(3):399-404. doi: 10.1007/s00540-022-03062-7. Epub 2022 Apr 27. |
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
Not provided
On the post-procedure questionnaire, the proceduralist will give a yes or no answer to the prompt to the question "Did the Bright Point Epidural color graphic improve your understanding of where your needle tip is or what tissue it is in?" |
| Post-operation (after the surgery is complete) |
| The time it takes to insert the epidural needle into the patient's skin. | The time between when the patient entered the operating room and when the epidural needle was inserted into the patient's skin. | From "in OR time" to "time when needle is inserted" |
| The time it takes to successfully identify the epidural space. | The time between inserting an epidural needle into the skin and successfully identifying the epidural space. | From "time when needle is inserted" to "time when epidural space is identified" |
| The percentage of Successful Neuraxial Procedures | The percentage of successful neuraxial procedures, calculated by dividing "the number successful neuraxial procedures placed without assistance or complication by the number of attempted neuraxial procedures" | Post-operation (after the surgery is complete) |